Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Thromb Res ; 86(5): 373-83, 1997 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-9211628

RESUMO

Assay conditions of a plasma-based ecarin clotting time (ECT) were evaluated and the precision of the ECT in monitoring plasma levels of r-hirudin assessed. The snake venom enzyme ecarin converts prothrombin to meizothrombin possessing only weak coagulant but strong esterase activity. In r-hirudin containing plasma samples, meizo thrombin is rapidly neutralized by r-hirudin resulting in a dose-dependent prolongation of the clotting times. Among the different assay conditions tested, addition of 50 microliters of ecarin (4 U/ml) to 100 microliters of undiluted citrate-anticoagulated plasma gave optimal results with respect to precision and reproducibility. The measuring range of the ECT performed in this way is about 0.02-5.0 micrograms/ml r-hirudin. In vitro studies performed on r-hirudin-spiked plasma samples of 50 healthy individuals demonstrate remarkably low interindividual differences in r-hirudin responsiveness as indicated by CV-values below 5% and 7% at r-hirudin concentrations between 0-3 micrograms/ml and 4-5 micrograms/ml, respectively. The specificity for r-hirudin of the ECT is further demonstrated by the strong correlation (r = 0.94) between the results of a chromogenic assay and the ECT-measured r-hirudin concentrations obtained on 67 ex vivo blood samples. Depending on the concentration of r-hirudin the ECT is sensitive to plasma levels of prothrombin. In the absence of r-hirudin the critical prothrombin concentration was found to be 20% but increasing to 60% in the presence of 2.0 micrograms/ml r-hirudin. A fibrinogen concentration of 50 mg/dl was found to be the minimal concentration independent of the r-hirudin concentration. The precision of the ECT in measuring plasma levels of r-hirudin is not influenced by treatment with heparin, aprotinin or oral anticoagulants. The data demonstrate that the ECT is a rapid and easily perfor mable clotting assay which allows accurate measurement of r-hirudin plasma levels. ECT-monitored hirudin treatment will help to establish optimal dose regimens that are more efficacious but still as safe as heparin.


Assuntos
Antitrombinas/metabolismo , Hirudinas/sangue , Administração Oral , Anticoagulantes/administração & dosagem , Antitrombinas/administração & dosagem , Antitrombinas/efeitos adversos , Testes de Coagulação Sanguínea/métodos , Testes de Coagulação Sanguínea/estatística & dados numéricos , Endopeptidases , Fibrinogênio/metabolismo , Hirudinas/administração & dosagem , Hirudinas/efeitos adversos , Humanos , Técnicas In Vitro , Tempo de Tromboplastina Parcial , Protrombina/metabolismo , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/sangue , Valores de Referência , Reprodutibilidade dos Testes , Segurança
2.
Thromb Haemost ; 77(5): 920-5, 1997 May.
Artigo em Inglês | MEDLINE | ID: mdl-9184403

RESUMO

The use of recombinant (r) hirudin as an anticoagulant in performing extracorporeal circulation systems including cardiopulmonary bypass (CPB) devices requires a specific and easy to handle monitoring system. The usefulness of the celite-induced activated clotting time (ACT) and the activated partial thromboplastin time (APTT) for r-hirudin monitoring has been tested on ex vivo blood samples obtained from eight patients treated with r-hirudin during open heart surgery. The very poor relationship between the prolongation of the ACT and APTT values and the concentration of r-hirudin as measured using a chromogenic factor IIa assay indicates that both assays are not suitable to monitor r-hirudin anticoagulation. As an alternative approach a whole blood clotting assay based on the prothrombin-activating snake venom ecarin has been tested. In vitro experiments using r-hirudin-spiked whole blood samples showed a linear relationship between the concentration of hirudin added and the prolongation of the clotting times up to a concentration of r-hirudin of 4.0 micrograms/ml. Interassay coefficients (CV) of variation between 2.1% and 5.4% demonstrate the accuracy of the ecarin clotting time (ECT) assay. Differences in the interindividual responsiveness to r-hirudin were analyzed on r-hirudin-spiked blood samples obtained from 50 healthy blood donors. CV-values between 1.8% and 6% measured at r-hirudin concentrations between 0.5 and 4 micrograms/ml indicate remarkably slight differences in r-hirudin responsiveness. ECT assay results of the ex vivo blood samples linearily correlate (r = 0.79) to the concentration of r-hirudin. Moreover, assay results were not influenced by treatment with aprotinin or heparin. These findings together with the short measuring time with less than 120 seconds warrant the whole blood ECT to be a suitable assay for monitoring of r-hirudin anticoagulation in cardiac surgery.


Assuntos
Ponte Cardiopulmonar , Fibrinolíticos/uso terapêutico , Terapia com Hirudina , Ponte de Artéria Coronária , Endopeptidases , Fibrinolíticos/administração & dosagem , Próteses Valvulares Cardíacas , Heparina/efeitos adversos , Hirudinas/administração & dosagem , Humanos , Monitorização Intraoperatória , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/uso terapêutico , Valores de Referência , Análise de Regressão , Reprodutibilidade dos Testes , Trombocitopenia/induzido quimicamente , Trombocitopenia/prevenção & controle , Venenos de Víboras , Tempo de Coagulação do Sangue Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA