Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Br J Gen Pract ; 73(726): e16-e23, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36316162

RESUMO

BACKGROUND: Ambulatory blood-pressure monitoring (ABPM) has become less frequent in primary care since the COVID-19 pandemic, with home blood-pressure monitoring (HBPM) often the preferred alternative; however, HBPM cannot measure night-time blood pressure (BP), and patients whose night-time BP does not dip, or rises (reverse dipping), have poorer cardiovascular outcomes. AIM: To investigate the importance of measuring night-time BP when assessing individuals for hypertension. DESIGN AND SETTING: Retrospective cohort study of two patient populations - namely, hospital patients admitted to four UK acute hospitals located in Oxfordshire, and participants of the BP in different ethnic groups (BP-Eth) study, who were recruited from 28 UK general practices in the West Midlands. METHOD: Using BP data collected for the two cohorts, three systolic BP phenotypes (dipper, non-dipper, and reverse dipper) were studied. RESULTS: Among the hospital cohort, 48.9% (n = 10 610/21 716) patients were 'reverse dippers', with an average day-night systolic BP difference of +8.0 mmHg. Among the community (BP-Eth) cohort, 10.8% (n = 63/585) of patients were reverse dippers, with an average day-night systolic BP difference of +8.5 mmHg. Non-dipper and reverse-dipper phenotypes both had lower daytime systolic BP and higher night-time systolic BP than the dipper phenotype. Average daytime systolic BP was lowest in the reverse-dipping phenotype (this was 6.5 mmHg and 6.8 mmHg lower than for the dipper phenotype in the hospital and community cohorts, respectively), thereby placing them at risk of undiagnosed, or masked, hypertension. CONCLUSION: Not measuring night-time BP puts all groups, other than dippers, at risk of failure to identify hypertension. As a result of this study, it is recommended that GPs should offer ABPM to all patients aged ≥60 years as a minimum when assessing for hypertension.


Assuntos
COVID-19 , Hipertensão , Humanos , Pressão Sanguínea/fisiologia , Estudos Retrospectivos , Pandemias , Ritmo Circadiano/fisiologia , COVID-19/diagnóstico , COVID-19/epidemiologia , Hipertensão/diagnóstico , Monitorização Ambulatorial da Pressão Arterial , Atenção Primária à Saúde
3.
Nat Commun ; 12(1): 915, 2021 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-33568665

RESUMO

Dexamethasone can reduce mortality in hospitalised COVID-19 patients needing oxygen and ventilation by 18% and 36%, respectively. Here, we estimate the potential number of lives saved and life years gained if this treatment were to be rolled out in the UK and globally, as well as the cost-effectiveness of implementing this intervention. Assuming SARS-CoV-2 exposure levels of 5% to 15%, we estimate that, for the UK, approximately 12,000 (4,250 - 27,000) lives could be saved between July and December 2020. Assuming that dexamethasone has a similar effect size in settings where access to oxygen therapies is limited, this would translate into approximately 650,000 (240,000 - 1,400,000) lives saved globally over the same time period. If dexamethasone acts differently in these settings, the impact could be less than half of this value. To estimate the full potential of dexamethasone in the global fight against COVID-19, it is essential to perform clinical research in settings with limited access to oxygen and/or ventilators, for example in low- and middle-income countries.


Assuntos
Tratamento Farmacológico da COVID-19 , Dexametasona/uso terapêutico , COVID-19/economia , COVID-19/mortalidade , COVID-19/terapia , Análise Custo-Benefício , Dexametasona/economia , Mortalidade Hospitalar , Hospitalização , Humanos , Anos de Vida Ajustados por Qualidade de Vida , Respiração Artificial , SARS-CoV-2 , Reino Unido/epidemiologia , Ventiladores Mecânicos
4.
PLoS One ; 15(1): e0227651, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31923919

RESUMO

We tested the influence of blood pressure variability on the reproducibility of dynamic cerebral autoregulation (DCA) estimates. Data were analyzed from the 2nd CARNet bootstrap initiative, where mean arterial blood pressure (MABP), cerebral blood flow velocity (CBFV) and end tidal CO2 were measured twice in 75 healthy subjects. DCA was analyzed by 14 different centers with a variety of different analysis methods. Intraclass Correlation (ICC) values increased significantly when subjects with low power spectral density MABP (PSD-MABP) values were removed from the analysis for all gain, phase and autoregulation index (ARI) parameters. Gain in the low frequency band (LF) had the highest ICC, followed by phase LF and gain in the very low frequency band. No significant differences were found between analysis methods for gain parameters, but for phase and ARI parameters, significant differences between the analysis methods were found. Alternatively, the Spearman-Brown prediction formula indicated that prolongation of the measurement duration up to 35 minutes may be needed to achieve good reproducibility for some DCA parameters. We conclude that poor DCA reproducibility (ICC<0.4) can improve to good (ICC > 0.6) values when cases with low PSD-MABP are removed, and probably also when measurement duration is increased.


Assuntos
Determinação da Pressão Arterial/métodos , Circulação Cerebrovascular/fisiologia , Homeostase/fisiologia , Adulto , Idoso , Pressão Arterial/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Média/fisiopatologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA