Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Circ Cardiovasc Interv ; 17(4): e013702, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38525609

RESUMO

BACKGROUND: Intravascular imaging and intracoronary physiology may both be used to guide and optimize percutaneous coronary intervention; however, they are rarely used together. The virtual flow reserve (VFR) is an optical coherence tomography (OCT)-based model of fractional flow reserve (FFR) facilitating the assessment of the physiological significance of coronary lesions. We aimed to validate the VFR assessment of intermediate coronary artery stenoses. METHODS: FUSION (Validation of OCT-Based Functional Diagnosis of Coronary Stenosis) was a multicenter, prospective, observational study comparing OCT-derived VFR to invasive FFR. VFR was mathematically derived from a lumped parameter flow model based on 3-dimensional lumen morphology. Patients undergoing coronary angiography with intermediate angiographic stenosis (40%-90%) requiring physiological assessment were enrolled. Investigational sites were blinded to the VFR analysis, and all OCT and FFR data were reviewed by an independent core laboratory. The coprimary end points were the sensitivity and specificity of VFR against FFR as the reference standard, each of which was tested against prespecified performance goals. RESULTS: After core laboratory review, 266 vessels in 224 patients from 25 US centers were included in the analysis. The mean angiographic diameter stenosis was 65.5%±14.9%, and the mean FFR was 0.83±0.11. Overall accuracy, sensitivity, and specificity of VFR versus FFR using a binary cutoff point of 0.80 were 82.0%, 80.4%, and 82.9%, respectively. The 97.5% lower confidence bound met the prespecified performance goal for sensitivity (71.6% versus 70%; P=0.01) and specificity (76.6% versus 75%; P=0.01). The area under the curve was 0.88 (95% CI, 0.84-0.92; P<0.0001). CONCLUSIONS: OCT-derived VFR demonstrates high sensitivity and specificity for predicting invasive FFR. Integrating high-resolution intravascular imaging with imaging-derived physiology may provide synergistic benefits as an adjunct to percutaneous coronary intervention. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT04356027.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Constrição Patológica , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Resultado do Tratamento , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Angiografia Coronária/métodos , Vasos Coronários , Valor Preditivo dos Testes , Índice de Gravidade de Doença
2.
Am Heart J ; 231: 147-156, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33031789

RESUMO

Dual antiplatelet therapy (DAPT) is key for the prevention of recurrent ischemic events after percutaneous coronary intervention (PCI); however, it increases the risk of bleeding complications. While new generation drug-eluting stents have been shown superior to bare-metal stents after a short DAPT course, the optimal DAPT duration in patients at high bleeding risk (HBR) remains to be determined. TRIAL DESIGN: The XIENCE Short DAPT program consists of three prospective, single-arm studies (XIENCE 90, XIENCE 28 Global and XIENCE 28 USA) investigating 3- or 1-month DAPT durations in HBR patients undergoing PCI with the XIENCE stent. The XIENCE 90 study is being conducted in the US and enrolled 2047 subjects who discontinued DAPT at 3 months if they were free from myocardial infarction (MI), repeat coronary revascularization, stroke, or stent thrombosis. The XIENCE 28 program includes the USA study, enrolling 642 patients in US and Canada, and the Global study, enrolling 963 patients in Europe and Asia. In XIENCE 28, patients were to discontinue DAPT at 1 month post-PCI if event-free. The primary hypothesis for both XIENCE 90 and XIENCE 28 is that a short DAPT regimen will be non-inferior to a conventional DAPT duration with respect to the composite of all-cause death or MI. Patients enrolled in the prospective multicenter post-market XIENCE V USA study will be used as historical control group in a stratified propensity-adjusted analysis. CONCLUSIONS: The XIENCE Short DAPT Program will provide insights into the safety and efficacy of 2 abbreviated DAPT regimens of 3- and 1-month duration in a large cohort of HBR patients undergoing PCI with the XIENCE stent.


Assuntos
Síndrome Coronariana Aguda/tratamento farmacológico , Aspirina/administração & dosagem , Stents Farmacológicos , Everolimo/administração & dosagem , Imunossupressores/administração & dosagem , Infarto do Miocárdio/prevenção & controle , Inibidores da Agregação Plaquetária/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Aspirina/efeitos adversos , Canadá , Causas de Morte , Esquema de Medicação , Stents Farmacológicos/efeitos adversos , Hemorragia/induzido quimicamente , Hemorragia/prevenção & controle , Humanos , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/efeitos adversos , Estudos Prospectivos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Acidente Vascular Cerebral , Trombose , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA