RESUMO
AIMS: Although mobile health tools using photoplethysmography (PPG) technology have been validated for the detection of atrial fibrillation (AF), their utility for heart rate assessment during AF remains unclear. Therefore, we aimed to evaluate the accuracy of continuous PPG-based 1 min mean heart rate assessment during AF. METHODS AND RESULTS: Persistent AF patients were provided with Holter electrocardiography (ECG) (for ≥24 h) simultaneously with a PPG-equipped smartwatch. Both the PPG-based smartwatch and Holter ECG automatically and continuously monitored patients' heart rate/rhythm. ECG and PPG recordings were synchronized and divided into 1 min segments, from which a PPG-based and an ECG-based average heart rate estimation were extracted. In total, 47 661 simultaneous ECG and PPG 1 min heart rate segments were analysed in 50 patients (34% women, age 73 ± 8 years). The agreement between ECG-determined and PPG-determined 1 min mean heart rate was high [root mean squared error (RMSE): 4.7 bpm]. The 1 min mean heart rate estimated using PPG was accurate within ±10% in 93.7% of the corresponding ECG-derived 1 min mean heart rate segments. PPG-based 1 min mean heart rate estimation was more often accurate during night-time (97%) than day-time (91%, P < 0.001) and during low levels (96%) compared to high levels of motion (92%, P < 0.001). A neural network with a 10 min history of the recording did not further improve the PPG-based 1 min mean heart rate assessment [RMSE: 4.4 (95% confidence interval: 3.5-5.2 bpm)]. Only chronic heart failure was associated with a lower agreement between ECG-derived and PPG-derived 1 min mean heart rates (P = 0.040). CONCLUSION: During persistent AF, continuous PPG-based 1 min mean heart rate assessment is feasible in 60% of the analysed period and shows high accuracy compared with Holter ECG for heart rates <110 bpm.
Assuntos
Fibrilação Atrial , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Fibrilação Atrial/diagnóstico , Frequência Cardíaca , Fotopletismografia/métodos , Eletrocardiografia/métodos , Eletrocardiografia Ambulatorial , AlgoritmosRESUMO
INTRODUCTION: The TeleCheck-AF approach is an on-demand mobile health (mHealth) infrastructure incorporating mobile app-based heart rate and rhythm monitoring through teleconsultation. We evaluated feasibility and accuracy of self-reported mHealth-based AF risk factors and CHA2DS2-VASc-score in atrial fibrillation (AF) patients managed within this approach. MATERIALS AND METHODS: Consecutive patients from eight international TeleCheck-AF centers were asked to complete an app-based 10-item questionnaire related to risk factors, associated conditions and CHA2DS2-VASc-score components. Patient's medical history was retrieved from electronic health records (EHR). RESULTS: Among 994 patients, 954 (96%) patients (38% female, median age 65 years) completed the questionnaire and were included in this analysis. The accuracy of self-reported assessment was highest for pacemaker and anticoagulation treatment and lowest for heart failure and arrhythmias. Patients who knew that AF increases the stroke risk, more often had a 100% or ≥80% correlation between EHR- and app-based results compared to those who did not know (27 vs. 14% or 84 vs. 77%, P = 0.001). Thromboembolic events were more often reported in app (vs. EHR) in all countries, whereas higher self-reported hypertension and anticoagulant treatment were observed in Germany and heart failure in the Netherlands. If the app-based questionnaire alone was used for clinical decision-making on anticoagulation initiation, 26% of patients would have been undertreated and 6.1%-overtreated. CONCLUSION: Self-reported mHealth-based assessment of AF risk factors is feasible. It shows high accuracy of pacemaker and anticoagulation treatment, nevertheless, displays limited accuracy for some of the CHA2DS2-VASc-score components. Direct health care professional assessment of risk factors remains indispensable to ensure high quality clinical-decision making.
RESUMO
BACKGROUND: Although novel teleconsultation solutions can deliver remote situations that are relatively similar to face-to-face interaction, remote assessment of heart rate and rhythm as well as risk factors remains challenging in patients with atrial fibrillation (AF). HYPOTHESIS: Mobile health (mHealth) solutions can support remote AF management. METHODS: Herein, we discuss available mHealth tools and strategies on how to incorporate the remote assessment of heart rate, rhythm and risk factors to allow comprehensive AF management through teleconsultation. RESULTS: Particularly, in the light of the coronavirus disease 2019 (COVID-19) pandemic, there is decreased capacity to see patients in the outpatient clinic and mHealth has become an important component of many AF outpatient clinics. Several validated mHealth solutions are available for remote heart rate and rhythm monitoring as well as for risk factor assessment. mHealth technologies can be used for (semi-)continuous longitudinal monitoring or for short-term on-demand monitoring, dependent on the respective requirements and clinical scenarios. As a possible solution to improve remote AF care through teleconsultation, we introduce the on-demand TeleCheck-AF mHealth approach that allows remote app-based assessment of heart rate and rhythm around teleconsultations, which has been developed and implemented during the COVID-19 pandemic in Europe. CONCLUSION: Large scale international mHealth projects, such as TeleCheck-AF, will provide insight into the additional value and potential limitations of mHealth strategies to remotely manage AF patients. Such mHealth infrastructures may be well suited within an integrated AF-clinic, which may require redesign of practice and reform of health care systems.
Assuntos
Fibrilação Atrial/terapia , Betacoronavirus , Infecções por Coronavirus/epidemiologia , Controle de Infecções/organização & administração , Pneumonia Viral/epidemiologia , Consulta Remota/organização & administração , COVID-19 , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/transmissão , Humanos , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Pneumonia Viral/transmissão , SARS-CoV-2RESUMO
Fibrotic remodeling of the heart is a frequent condition linked to various diseases and cardiac dysfunction. Collagen quantification is an important objective in cardiac fibrosis research; however, a variety of different histological methods are currently used that may differ in accuracy. Here, frequently applied collagen quantification techniques were compared. A porcine model of early stage heart failure with preserved ejection fraction was used as an example. Semiautomated threshold analyses were imprecise, mainly due to inclusion of noncollagen structures or failure to detect certain collagen deposits. In contrast, collagen assessment by automated image analysis and light microscopy (LM)-stereology was more sensitive. Depending on the quantification method, the amount of estimated collagen varied and influenced intergroup comparisons. PicroSirius Red, Masson's trichrome, and Azan staining protocols yielded similar results, whereas the measured collagen area increased with increasing section thickness. Whereas none of the LM-based methods showed significant differences between the groups, electron microscopy (EM)-stereology revealed a significant collagen increase between cardiomyocytes in the experimental group, but not at other localizations. In conclusion, in contrast to the staining protocol, section thickness and the quantification method being used directly influence the estimated collagen content and thus, possibly, intergroup comparisons. EM in combination with stereology is a precise and sensitive method for collagen quantification if certain prerequisites are considered. For subtle fibrotic alterations, consideration of collagen localization may be necessary. Among LM methods, LM-stereology and automated image analysis are appropriate to quantify fibrotic changes, the latter depending on careful control of algorithm and comparable section staining.NEW & NOTEWORTHY Direct comparison of frequently applied histological fibrosis assessment techniques revealed a distinct relation of measured collagen and utilized quantification method as well as section thickness. Besides electron microscopy-stereology, which was precise and sensitive, light microscopy-stereology and automated image analysis proved to be appropriate for collagen quantification. Moreover, consideration of collagen localization might be important in revealing minor fibrotic changes.