Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
JAMA Netw Open ; 7(2): e2356479, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38363565

RESUMO

Importance: The COVID-19 pandemic resulted in delayed access to medical care. Restrictions to health care specialists, staff shortages, and fear of SARS-CoV-2 infection led to interruptions in routine care, such as early melanoma detection; however, premature mortality and economic burden associated with this postponement have not been studied yet. Objective: To determine the premature mortality and economic costs associated with suspended melanoma screenings during COVID-19 pandemic lockdowns by estimating the total burden of delayed melanoma diagnoses for Europe. Design, Setting, and Participants: This multicenter economic evaluation used population-based data from patients aged at least 18 years with invasive primary cutaneous melanomas stages I to IV according to the American Joint Committee on Cancer (AJCC) seventh and eighth editions, including melanomas of unknown primary (T0). Data were collected from January 2017 to December 2021 in Switzerland and from January 2019 to December 2021 in Hungary. Data were used to develop an estimation of melanoma upstaging rates in AJCC stages, which was verified with peripandemic data. Years of life lost (YLL) were calculated and were, together with cost data, used for financial estimations. The total financial burden was assessed through direct and indirect treatment costs. Models were building using data from 50 072 patients aged 18 years and older with invasive primary cutaneous melanomas stages I to IV according to the AJCC seventh and eighth edition, including melanomas of unknown primary (T0) from 2 European tertiary centers. Data from European cancer registries included patient-based direct and indirect cost data, country-level economic indicators, melanoma incidence, and population rates per country. Data were analyzed from July 2021 to September 2022. Exposure: COVID-19 lockdown-related delay of melanoma detection and consecutive public health and economic burden. As lockdown restrictions varied by country, lockdown scenario was defined as elimination of routine medical examinations and severely restricted access to follow-up examinations for at least 4 weeks. Main Outcomes and Measures: Primary outcomes were the total burden of a delay in melanoma diagnosis during COVID-19 lockdown periods, measured using the direct (in US$) and indirect (calculated as YLL plus years lost due to disability [YLD] and disability-adjusted life-years [DALYs]) costs for Europe. Secondary outcomes included estimation of upstaging rate, estimated YLD, YLL, and DALY for each European country, absolute direct and indirect treatment costs per European country, proportion of the relative direct and indirect treatment costs for the countries, and European health expenditure. Results: There were an estimated 111 464 (range, 52 454-295 051) YLL due to pandemic-associated delay in melanoma diagnosis in Europe, and estimated total additional costs were $7.65 (range, $3.60 to $20.25) billion. Indirect treatment costs were the main cost driver, accounting for 94.5% of total costs. Estimates for YLD in Europe resulted in 15 360 years for the 17% upstaging model, ranging from 7228 years (8% upstaging model) to 40 660 years (45% upstaging model). Together, YLL and YLD constitute the overall disease burden, ranging from 59 682 DALYs (8% upstaging model) to 335 711 DALYs (45% upstaging model), with 126 824 DALYs for the real-world 17% scenario. Conclusions and Relevance: This economic analysis emphasizes the importance of continuing secondary skin cancer prevention measures during pandemics. Beyond the personal outcomes of a delayed melanoma diagnosis, the additional economic and public health consequences are underscored, emphasizing the need to include indirect economic costs in future decision-making processes. These estimates on DALYs and the associated financial losses complement previous studies highlighting the cost-effectiveness of screening for melanoma.


Assuntos
COVID-19 , Melanoma , Neoplasias Primárias Desconhecidas , Neoplasias Cutâneas , Humanos , Adolescente , Adulto , Melanoma/diagnóstico , Melanoma/epidemiologia , Pandemias , Neoplasias Primárias Desconhecidas/epidemiologia , COVID-19/diagnóstico , COVID-19/epidemiologia , SARS-CoV-2 , Controle de Doenças Transmissíveis , Europa (Continente)/epidemiologia , Efeitos Psicossociais da Doença , Neoplasias Cutâneas/diagnóstico , Neoplasias Cutâneas/epidemiologia , Teste para COVID-19
2.
iScience ; 27(1): 108677, 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38213618

RESUMO

Fractional laser (FL) treatment is a common dermatologic procedure that generates arrays of microscopic treatment zones separated by intact tissue, promoting fast wound healing. Using a mouse model, we introduced a large area fractional laser treatment (LAFLT) method to study metabolic effects. Using two laser modalities, ablative FL (AFL) and non-ablative FL (NAFL), and exposing different percentages of mice's total body surface area (TBSA), we followed changes in metabolic parameters in real time using metabolic cages. Additionally, body composition, markers of inflammation, neurohormonal signaling, and browning of adipocytes were investigated. LAFLT, especially in high TBSA groups, had specific metabolic effects such as significantly increased average daily energy expenditure, increased fat mass loss, systemic browning of adipocytes, and inflammatory states, without compromising other organs. The ability of LAFLT to stimulate metabolism in a controlled way could develop into a promising therapeutic treatment to induce positive metabolic changes that replace or augment systemic drugs.

3.
Lasers Surg Med ; 55(9): 838-845, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37434586

RESUMO

OBJECTIVES: Lip filler injections are one of the most popular procedures in esthetic dermatology. In this study, we used three-dimensional colorimetric photography to assess lip color and optical coherence tomography-angiography (OCT-A), a noninvasive alternative to histopathology, to evaluate microcirculation after hyaluronic acid (HA) injection. The pain of the injection procedure was also assessed. METHODS: An average of 0.85cc of the total volume of HA with lidocaine was injected into the upper and lower lip of eighteen young (<30yo) and nine postmenopausal healthy women. OCT-A, two-dimensional, and three-dimensional images were acquired immediately before (visit 1) and 15 days after injection (visit 2). Custom-made software was used to analyze the imaging data to detect vessel morphology and redness changes. The Wong-Baker FACES pain rating scale (0-10) was used to score the subject procedural pain. RESULTS: For young and old subjects, three-dimensional lip volume was greater than the injected volume. OCT-A images of the lips showed higher vessel density and thickness, reaching statistical significance in the younger cohort. The overall trend of increased redness assessed by three-dimensional colorimetric imaging and increased vascularity evaluated by OCT-A imaging were similar. However, the correlation was not statistically significant for standard two-dimensional digital photography. The average pain score after the first needle insertion and overall procedure were 2.9 and 3.5, respectively. CONCLUSIONS: The results suggest an increased microvasculature network observed in OCT-A images in young females. The increased blood vessel density and thickness observed by OCT-A after HA lip filler injection is associated with increased lip redness and volume as assessed by colorimetric three-dimensional photography; however, more research is needed to confirm these findings. This study presents OCT-A as a novel noninvasive tool to investigate changes in lip microvascularity after HA filler injection and indicates that HA filler procedures may affect lip vascularity.

4.
Lasers Surg Med ; 54(6): 851-860, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35395696

RESUMO

BACKGROUND AND OBJECTIVES: Mid-infrared (IR) ablative fractional laser treatments are highly efficacious for improving the appearance of a variety of dermatological conditions such as photo-aged skin. However, articulated arms are necessary to transmit the mid-IR light to the skin, which restricts practicality and clinical use. Here, we have assessed and characterized a novel fiber laser-pumped difference frequency generation (DFG) system that generates ablative fractional lesions and compared it to clinically and commercially available thulium fiber, Erbium:YAG (Er:YAG), and CO2 lasers. MATERIALS AND METHODS: An investigational 20 W, 3050/3200 nm fiber laser pumped DFG system with a focused spot size of 91 µm was used to generate microscopic ablation arrays in ex vivo human skin. Several pulse energies (10-70 mJ) and pulse durations (2-14 ms) were applied and lesion dimensions were assessed histologically using nitro-blue tetrazolium chloride stain. Ablation depths and coagulative thermal damage zones were analyzed across three additional laser systems. RESULTS: The investigational DFG system-generated deep (>2 mm depth) and narrow (<100 µm diameter) ablative lesions surrounded by thermal coagulative zones of at least 20 µm thickness compared to 13, 40, and 320 µm by the Er:YAG, CO2 , and Thulium laser, respectively. CONCLUSION: The DFG system is a small footprint device that offers a flexible fiber delivery system for ablative fractional laser treatments, thereby overcoming the requirement of an articulated arm in current commercially available ablative lasers. The depth and width of the ablated microcolumns and the extent of surrounding coagulation can be controlled; this concept can be used to design new treatment procedures for specific indications. Clinical improvements and safety are not the subject of this study and need to be explored with in vivo clinical studies.


Assuntos
Dermatologia , Terapia a Laser , Lasers de Gás , Lasers de Estado Sólido , Envelhecimento da Pele , Idoso , Dióxido de Carbono , Humanos , Terapia a Laser/métodos , Lasers de Gás/uso terapêutico , Lasers de Estado Sólido/uso terapêutico , Pele/patologia , Túlio
5.
Lasers Surg Med ; 52(8): 788-798, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-31943251

RESUMO

BACKGROUND AND OBJECTIVES: A recent generation of 5,500 nm wavelength carbon monoxide (CO) lasers could serve as a novel tool for applications in medicine and surgery. At this wavelength, the optical penetration depth is about three times higher than that of the 10,600 nm wavelength carbon dioxide (CO2 ) laser. As the amount of ablation and coagulation is strongly influenced by the wavelength, we anticipated that CO lasers would provide extended coagulation zones, which could be beneficial for several medical applications, such as tissue tightening effects after laser skin resurfacing. Until now, the 1,940 nm wavelength thulium fiber (Tm:fiber) laser is primarily known as a non-ablative laser with an optical penetration depth that is eight times higher than that of the CO2 laser. The advantage of lasers with shorter wavelengths is the ability to create smaller spot sizes, which has a determining influence on the ablation outcome. In this study, the ablation and coagulation characteristics of a novel CO laser and a high power Tm:fiber laser were investigated to evaluate their potential application for fractional ablation of the skin. STUDY DESIGN/MATERIALS AND METHODS: Laser-tissue exposures were performed using a novel CO laser, a modified, pulse-width-modulated CO2 laser, and a Tm:fiber laser. We used discarded ex vivo human skin obtained from abdominoplasty as tissue samples. Similar exposure parameters, such as spot size (108-120 µm), pulse duration (2 milliseconds), and pulse energy (~10-200 mJ) were adjusted for the different laser systems with comparable temporal pulse structures. Laser effects were quantified by histology. RESULTS: At radiant exposures 10-fold higher than the ablation threshold, the CO laser ablation depth was almost two times deeper than that of the CO2 laser. At 40-fold of the ablation threshold, the CO laser ablation was 47% deeper. The ablation craters produced by the CO laser exhibited about two times larger coagulation zones when compared with the CO2 laser. In contrast, the Tm:fiber laser exhibited superficial ablation craters with massive thermal damage. CONCLUSIONS: The tissue ablation using the Tm:fiber laser was very superficial in contrast to the CO laser and the CO2 laser. However, higher etch depths should be obtainable when the radiant exposure is increased by using higher pulse energies and/or smaller spot sizes. At radiant exposures normalized to the ablation threshold, the CO laser was capable of generating deeper ablation craters with extended coagulation zones compared with the CO2 laser, which is possibly desirable depending on the clinical goal. The effect of deep ablation combined with additional thermal damage on dermal remodeling needs to be further confirmed with in vivo studies. Lasers Surg. Med. © 2020 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.


Assuntos
Terapia a Laser , Lasers de Gás , Monóxido de Carbono , Humanos , Lasers de Gás/uso terapêutico , Pele , Túlio
6.
Lasers Surg Med ; 50(9): 961-972, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29799127

RESUMO

BACKGROUND: Traditionally, fractional laser treatments are performed with focused laser sources operating at a fixed wavelength. Using a tunable laser in the mid-infrared wavelength range, wavelength-dependent absorption properties on the ablation process and thermal damage formation were assessed with the goal to obtain customizable tissue ablations to provide guidance in finding optimized laser exposure parameters for clinical applications. METHODS: Laser tissue experiments were carried out on full thickness ex vivo human abdominal skin using a mid-infrared tunable chromium-doped zinc selenide/sulfide chalcogenide laser. The laser has two independent channels: a continuous wave (CW) output channel which covers a spectrum ranging from 2.4 µm to 3.0 µm with up to 9.2 W output power, and a pulsed output channel which ranges from 2.35 µm to 2.95 µm. The maximum pulse energy of the pulsed channel goes up to 2.8 mJ at 100 Hz to 1,000 Hz repetition rate with wavelength-dependent pulse durations of 4-7 ns. RESULTS: Total ablation depth, ablation efficiency, and coagulation zone thickness were highly correlated to wavelength, pulse width, and pulse energy. Using the same total radiant exposure at 2.85 µm wavelength resulted in 10-times smaller coagulation zones and 5-times deeper ablation craters for one hundred 6 ns pulses compared to one 100 ms pulse. For a fixed pulse duration of 6 ns and a total radiant exposure of 2.25 kJ/cm2 the ablation depth increased with longer wavelengths. CONCLUSION: The tunable laser system provides a useful research tool to investigate specific laser parameters such as wavelength on lesion shape, ablation depth and thermal tissue damage. It also allows for customization of the characteristics of laser lesions and therefore facilitates the selection of suitable laser parameters for optimized fractional laser treatments. Lasers Surg. Med. 50:961-972, 2018.© 2018 Wiley Periodicals, Inc.


Assuntos
Calcogênios , Terapia a Laser/efeitos adversos , Lasers de Estado Sólido/efeitos adversos , Úlcera Cutânea/etiologia , Úlcera Cutânea/patologia , Pele/efeitos da radiação , Humanos , Técnicas de Cultura de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA