Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Interv Card Electrophysiol ; 66(4): 991-996, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36355272

RESUMO

BACKGROUND: Mathematical modelling has allowed calculation of the length of the slow and fast pathways in typical atrioventricular nodal reentrant tachycardia (AVNRT). The length of the slow pathway has been correlated with the measured length of the right inferior extension in human histologic specimens, but no histology data exist about the fast pathway. METHODS: In preparations of cadaveric human hearts, the AV node was identified, and the site of the fast pathway was projected according to both existing evidence and results of our electroanatomic mapping. This permitted measurement of the length of the fast pathway as a limb of the tachycardia circuit. RESULTS: Measurements of the length of the projected area of the fast pathway on histology specimens were performed in 8 hearts. The estimated length of the fast pathway was 39.6 ± 5.8 mm (range: 30.4-45.9 mm). These numbers are comparable to those produced by mathematical calculations of the length of the fast pathway. CONCLUSIONS: Typical AVNRT uses a circuit from the AV node to the septal isthmus of an average size of 5-6 cm, confined within the pyramid of Koch.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Nó Atrioventricular , Fascículo Atrioventricular , Arritmias Cardíacas , Taquicardia , Eletrocardiografia , Ablação por Cateter/métodos
2.
JMIR Hum Factors ; 9(4): e38048, 2022 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-36315217

RESUMO

BACKGROUND: Smartphone ownership and mobile app use are steadily increasing in individuals of diverse racial and ethnic backgrounds living in the United States. Growing adoption of technology creates a perfect opportunity for digital health interventions to increase access to health care. To successfully implement digital health interventions and engage users, intervention development should be guided by user input, which is best achieved by the process of co-design. Digital health interventions co-designed with the active engagement of users have the potential to increase the uptake of guideline recommendations, which can reduce morbidity and mortality and advance health equity. OBJECTIVE: We aimed to co-design a digital health intervention for patients with atrial fibrillation, the most common cardiac arrhythmia, with patient, caregiver, and clinician feedback and to describe our approach to human-centered design for building digital health interventions. METHODS: We conducted virtual meetings with patients with atrial fibrillation (n=8), their caregivers, and clinicians (n=8). We used the following 7 steps in our co-design process: step 1, a virtual meeting focused on defining challenges and empathizing with problems that are faced in daily life by individuals with atrial fibrillation and clinicians; step 2, a virtual meeting focused on ideation and brainstorming the top challenges identified during the first meeting; step 3, individualized onboarding of patients with an existing minimally viable version of the atrial fibrillation app; step 4, virtual prototyping of the top 3 ideas generated during ideation; step 5, further ranking by the study investigators and engineers of the ideas that were generated during ideation but were not chosen as top-3 solutions to be prototyped in step 4; step 6, ongoing engineering work to incorporate top-priority features in the app; and step 7, obtaining further feedback from patients and testing the atrial fibrillation digital health intervention in a pilot clinical study. RESULTS: The top challenges identified by patients and caregivers included addressing risk factor modification, medication adherence, and guidance during atrial fibrillation episodes. Challenges identified by clinicians were complementary and included patient education, addressing modifiable atrial fibrillation risk factors, and remote atrial fibrillation episode management. Patients brainstormed more than 30 ideas to address the top challenges, and the clinicians generated more than 20 ideas. Ranking of the ideas informed several novel or modified features aligned with the Theory of Health Behavior Change, features that were geared toward risk factor modification; patient education; rhythm, symptom, and trigger correlation for remote atrial fibrillation management; and social support. CONCLUSIONS: We co-designed an atrial fibrillation digital health intervention in partnership with patients, caregivers, and clinicians by virtually engaging in collaborative creation through the design process. We summarize our experience and describe a flexible approach to human-centered design for digital health intervention development that can guide innovative clinical investigators.

3.
Heart Rhythm O2 ; 3(6Part B): 799-806, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36589002

RESUMO

A nation's health and economic development are inextricably and synergistically connected. Stark differences exist between wealthy and developing nations in the use of cardiac implantable electronic devices (CIEDs). Cardiovascular disease is now the leading cause of death in low- and middle-income countries (LMIC), with a significant burden from rhythm-related diseases. As science, technology, education, and regulatory frameworks have improved, CIED recycling for exportation and reuse in LMIC has become possible and primed for widespread adoption. In our manuscript, we outline the science and regulatory pathways regarding CIED reuse. We propose a pathway to advance this technology that includes creating a task force to establish standards for CIED reuse, leveraging professional organizations in areas of need to foster the professional skills for CIED reuse, collaborating with regulatory agencies to create more efficient regulatory expectations and bring the concept to scale, and establishing a global CIED reuse registry for quality assurance and future science.

4.
Medicine (Baltimore) ; 100(51): e28356, 2021 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-34941150

RESUMO

ABSTRACT: Implantable cardiac monitors (ICMs) provide long-term electrocardiographic monitoring for a number of indications. However, frequencies of use by indication and temporal changes have not been characterized on a national scale. We sought to characterize overall use and changes between 2011 and 2018. We used generalized linear models to characterize the incidence rate per 1,000,000 patient-quarters at risk and an autoregressive integrated moving average model to account for autocorrelation in this time series data. We studied commercially-insured patients and their insured dependents in the IBM MarketScan Commercial Database who had an ICM placed. We described the characteristics of individuals who received ICMs and the frequency of placements into 3 guideline concordance groups. We estimated the mean change per quarter in ICM placements (mean quarterly change in incidence rate per 1,000,000 patient-quarters at risk) for quarter (Q)1 2011 through Q1 2014, Q1 2014 to Q2 2014, and Q2 2014 through Q4 2018 for each guideline concordance group. The most common indications for categorizable ICM placement were syncope (24%), atrial fibrillation (11%), and stroke (11%). For each of the 3 guideline concordance groups except guideline unaddressed inpatient ICM placements, there was a significant increase in use either during the Q1 2014 to Q2 2014 or the Q2 2014 through Q4 2018 periods. A significant portion of ICM placements were for indications that lack strong evidence, such as established atrial fibrillation. The incidence of ICM placement for most of the indications and settings increased after miniaturization and technical improvements.


Assuntos
Demandas Administrativas em Assistência à Saúde/estatística & dados numéricos , Fibrilação Atrial/diagnóstico por imagem , Eletrocardiografia Ambulatorial/instrumentação , Síncope/diagnóstico , Adolescente , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Eletrocardiografia , Eletrocardiografia Ambulatorial/economia , Feminino , Humanos , Masculino , Uso Excessivo dos Serviços de Saúde/tendências , Medicare , Pessoa de Meia-Idade , Acidente Vascular Cerebral/diagnóstico , Estados Unidos , Adulto Jovem
5.
Heart Rhythm O2 ; 1(4): 235-238, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34113877

RESUMO

BACKGROUND: An estimated 1 million patients require cardiac implantable electronic devices (CIEDs) but go without annually. This disparity exists in low-to-middle-income nations largely owing to the cost of CIED hardware. Humanitarian reuse of CIEDs has been shown to be safe and feasible. However, recent publications have raised concern that promotion of CIED reuse may foster a CIED "black market," to the dismay of manufacturers, regulators, and clinicians alike. OBJECTIVE: To determine if unregulated CIED sales for potential human use is a real issue by investigating unregulated public online CIED sale listings in the United States of America. METHODS: An observational study was undertaken over 6 months using multiple internet search engines from May 1 to November 1, 2019. We cataloged usable CIEDs (still in packaging, manufactured <7 years) and pricing. Manufacturers were contacted to determine status of sellers and unregulated CIEDs using model/serial numbers. RESULTS: In total, 58 CIEDs-47 implantable cardioverter-defibrillators and 11 permanent pacemakers-from 4 manufacturers were listed for sale on 3 websites. During the study period, 8 of 11 pacemakers and 37 of 47 implantable cardioverter-defibrillators were sold (price range: $100-$1500 [US dollars]). No new listings were seen in the last 3 months of observation, possibly owing to concomitant industry investigation. CONCLUSION: There does exist a public online market for unregulated CIED sales in the United States. This specific market seems to be small and unlikely to significantly expand with active monitoring by manufacturers and regulators.