Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 231
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Eur J Hum Genet ; 32(7): 827-836, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38637700

RESUMO

Genetic testing can provide valuable information to mitigate personal disease risk, but the use of genetic results in life insurance underwriting is known to deter many consumers from pursuing genetic testing. In 2019, following Australian Federal Parliamentary Inquiry recommendations, the Financial Services Council (FSC) introduced an industry-led partial moratorium, prohibiting life insurance companies from using genetic test results for policies up to $AUD500,000. We used semi-structured interviews to explore genetic test consumers' experiences and views about the FSC moratorium and the use of genetic results by life insurers. Individuals who participated in an online survey and agreed to be re-contacted to discuss the issue further were invited. Interviews were 20-30-min long, conducted via video conference, transcribed verbatim and analysed using inductive content analysis. Twenty-seven participants were interviewed. Despite the moratorium, concerns about genetic discrimination in life insurance were prevalent. Participants reported instances where life insurers did not consider risk mitigation when assessing risk for policies based on genetic results, contrary to legal requirements. Most participants felt that the moratorium provided inadequate protection against discrimination, and that government legislation regulating life insurers' use of genetic results is necessary. Many participants perceived the financial limits to be inadequate, given the cost-of-living in Australia. Our findings indicate that from the perspective of participants, the moratorium has not been effective in allaying fears about genetic discrimination or ensuring adequate access to life insurance products. Concern about genetic discrimination in life insurance remains prevalent in Australia.


Assuntos
Testes Genéticos , Seguro de Vida , Humanos , Seguro de Vida/legislação & jurisprudência , Testes Genéticos/legislação & jurisprudência , Testes Genéticos/economia , Austrália , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Pesquisa Qualitativa
2.
Am J Med ; 137(4): 321-330.e7, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38190959

RESUMO

PURPOSE: There are concerns that transcatheter or surgical aortic valve replacement (TAVR/SAVR) procedures are preferentially available to White patients. Our objective was to examine differences in utilization of aortic valve replacement and outcomes by race/ethnicity in the US for patients with aortic stenosis. METHODS: We performed a serial cross-sectional cohort study of 299,976 Medicare beneficiaries hospitalized with principal diagnosis of aortic stenosis between 2012 and 2019 stratified by self-reported race/ethnicity (Black, Hispanic, Asian, Native American, and White). Outcomes included aortic valve replacement rates within 6 months of index hospitalization and associated procedural outcomes, including 30-day readmission, 30-day and 1-year mortality. RESULTS: Within 6 months of an index admission for aortic stenosis, 86.8% (122,457 SAVR; 138,026 TAVR) patients underwent aortic valve replacement. Overall, compared with White people, Black (HR 0.87 [0.85-0.89]), Hispanic (0.92 [0.88-0.96]), and Asian (0.95 [0.91-0.99]) people were less likely to receive aortic valve replacement. Among patients who were admitted emergently/urgently, White patients (41.1%, 95% CI, 40.7-41.4) had a significantly higher aortic valve replacement rate compared with Black (29.6%, 95% CI, 28.3-30.9), Hispanic (36.6%, 95% CI, 34.0-39.3), and Asian patients (35.4%, 95% CI, 32.3-38.9). Aortic valve replacement rates increased annually for all race/ethnicities. There were no significant differences in 30-day or 1-year mortality by race/ethnicity. CONCLUSIONS: Aortic valve replacement rates within 6 months of aortic stenosis admission are lower for Black, Hispanic, and Asian people compared to White people. These race-related differences in aortic stenosis treatment reflect complex issues in diagnosis and management, warranting a comprehensive reassessment of the entire care spectrum for disadvantaged populations.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Estados Unidos/epidemiologia , Valva Aórtica/cirurgia , Estudos Transversais , Medicare , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Fatores de Risco
3.
ORL Head Neck Nurs ; 42(1): 8-21, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38264200

RESUMO

Aims: The Post-extubation Assessment of Laryngeal Symptoms and Severity (PALSS) study systematically evaluates patient symptoms related to endotracheal intubation with mechanical ventilation, assesses laryngeal injury and voice function after extubation, and develops a screening tool to identify patients with clinically important, post-extubation laryngeal injury. Design: Single-center, prospective observational cohort study conducted in 6 intensive care units (ICU). Methods: Patients ≥18 years old who are orally intubated and mechanically ventilated in an ICU and meet eligibility criteria will undergo flexible laryngoscopy, with a sample size goal of 300 completed laryngoscopies. Primary outcome measures include signs and symptoms of laryngeal injury, including voice symptoms and alterations in swallowing, measured using the Laryngeal Hypersensitivity Questionnaire-Acute and Voice Symptom Scale questionnaires respectively. Data will be collected within 72 hours post-extubation and at 7-day follow-up or hospital discharge (whichever occurs first). Data will be analyzed using descriptive statistics, regression models, and predictive modeling using machine learning. Discussion: The findings of this study will describe the clinical signs and symptoms of laryngeal injury post-extubation. Conclusion: The PALSS study will provide insights for future studies that explore laryngeal injuries using flexible laryngoscopy after endotracheal intubation. Implications for patient care: Identifying signs and symptoms of laryngeal injury after endotracheal intubation will facilitate the development of a screening tool that will assist in early identification of post-extubation laryngeal injury, and aid in decreasing short- and long-term complications of endotracheal intubation. Reporting Method: SPIRIT. Patient or Public Contribution: Patients were study participants; and family members provided informed consent when the patient lacked decision-making capacity.

4.
Am J Otolaryngol ; 45(2): 104179, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38118384

RESUMO

PURPOSE: Tracheostomy care is supply- and resource-intensive, and airway-related adverse events in community settings have high rates of readmission and mortality. Devices are often implicated in harm, but little is known about insurance coverage, gaps, and barriers to obtaining tracheostomy-related medically necessary durable medical equipment. We aimed to identify barriers patients may encounter in procuring tracheostomy-related durable medical equipment through insurance plan coverage. MATERIALS AND METHODS: Tracheostomy-related durable medical equipment provisions were evaluated across insurers, extracting data via structured telephone interviews and web-based searches. Each insurance company was contacted four times and queried iteratively regarding the range of coverage and co-pay policies. Outcome measures include call duration, consistency of explanation of benefits, and the number of transfers and disconnects. We also identified six qualitative themes from patient interviews. RESULTS: Tracheostomy-related durable medical equipment coverage was offered in some form by 98.1 % (53/54) of plans across 11 insurers studied. Co-pays or deductibles were required in 42.6 % (23/54). There was significant variability in out-of-pocket expenditures. Fixed co-pays ranged from $0-30, and floating co-pays ranged from 0 to 40 %. During phone interviews, mean call duration was 19 ± 10 min, with an average of 2 ± 1 transfers between agents. Repeated calls revealed high information variability (mean score 2.4 ± 1.5). Insurance sites proved challenging to navigate, scoring poorly on usability, literacy, and information quality. CONCLUSIONS: Several factors may limit access to potentially life-saving durable medical equipment for patients with tracheostomy. Barriers include out-of-pocket expenditures, lack of transparency on coverage, and low-quality information. Further research is necessary to evaluate patient outcomes.


Assuntos
Equipamentos Médicos Duráveis , Traqueostomia , Humanos , Cobertura do Seguro
5.
Aust Crit Care ; 37(1): 138-143, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38135588

RESUMO

BACKGROUND: The Newcastle Laryngeal Hypersensitivity Questionnaire (LHQ) was developed to measure abnormal laryngeal sensation and was originally validated in a patient sample from otolaryngologic and respiratory outpatient clinics. Modification is needed for patients who are mechanically ventilated via an endotracheal tube or a tracheostomy tube. OBJECTIVES: We sought to adapt and preliminarily validate a modified version of the LHQ appropriate for nurses and other clinicians to administer in acute hospital settings called the LHQ-Acute (LHQ-A). METHODS: Internal consistency and construct validity analyses using secondary data from patients at a tertiary teaching hospital who presented with symptoms of laryngeal irritability/hypersensitivity between September 2012 and October 2013 were performed. RESULTS: A total of 131 patients, most complaining of coughing and dysphonia, with a median age of 58 (interquartile range: 48, 66) years and 29 healthy participants with a median age of 62 (interquartile range: 50, 66) years were analysed. The original LHQ was reduced from 14 questions with responses on a 7-point scale to the LHQ-A containing 13 questions with responses on a 4-point scale. Correlations between items of the LHQ and LHQ-A were similar, and internal consistency was excellent and highly comparable, with Cronbach's alpha = 0.906 and 0.902, respectively. CONCLUSIONS: The LHQ-A, which has been adapted for nurses and other clinicians to administer to a critically ill patient population, demonstrated comparable reliability and validity to the original LHQ. Validation of the LHQ-A in independent patient populations from acute settings is necessary to better understand norms and changes during recovery from acute illness.


Assuntos
Intubação Intratraqueal , Humanos , Reprodutibilidade dos Testes , Inquéritos e Questionários , Psicometria
6.
Artigo em Inglês | MEDLINE | ID: mdl-38082771

RESUMO

Cerebellar Ataxia (CA) is a neurological condition that affects coordination, balance and speech. Assessing its severity is important for developing effective treatment and rehabilitation plans. Traditional assessment methods involve a clinician instructing a person with ataxia to perform tests and assigning a severity score based on their performance. However, this approach is subjective as it relies on the clinician's experience, and can vary between clinicians. To address this subjectivity, some researchers have developed automated assessment methods using signal processing and data-driven approaches, such as supervised machine learning. These methods still rely on subjective ground truth and can perform poorly in real-world scenarios. This research proposed an alternative approach that uses signal processing to modify recurrence plots and compare the severity of ataxia in a person with CA to a control cohort. The highest correlation score obtained was 0.782 on the back sensor with the feet-apart and eyes-open test. The contributions of the research include modifying the recurrence plot as a measurement tool for assessing CA severity, proposing a new approach to assess severity by comparing kinematic data between people with CA and a control reference group, and identifying the best subtest and sensor position for practical use in CA assessments.


Assuntos
Ataxia Cerebelar , Humanos , Ataxia Cerebelar/diagnóstico , Ataxia , Fala , Fenômenos Biomecânicos
7.
JACC Cardiovasc Interv ; 16(12): 1437-1447, 2023 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-37380225

RESUMO

Mitral regurgitation is the most common valvular disease and is estimated to affect over 5 million Americans. Real-world data collection contributes to safety and effectiveness evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, and clinical best practice research. We aimed to establish a minimum core data set in mitral interventions to promote efficient, reusable real-world data collection for all of these purposes. Two expert task forces separately evaluated and reconciled a list of candidate elements derived from: 1) 2 ongoing transcatheter mitral trials; and 2) a systemic literature review of high-impact mitral trials and U.S multicenter, multidevice registries. From 703 unique data elements considered, unanimous consensus agreement was achieved on 127 "core" data elements, with the most common reasons for exclusion from the minimum core data set being burden or difficulty in accurate assessment (41.2%), duplicative information (25.0%), and low likelihood of affecting outcomes (19.6%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established and implemented into the national Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapies Registry 127 interoperable, reusable core data elements to support more efficient, consistent, and informative transcatheter mitral device evidence for regulatory submissions, safety surveillance, best practice development, and hospital quality assessments.


Assuntos
Cardiologia , Medicare , Idoso , Humanos , Estados Unidos , Resultado do Tratamento , Catéteres , Centers for Medicare and Medicaid Services, U.S. , Estudos Multicêntricos como Assunto
8.
Arch Phys Med Rehabil ; 104(10): 1646-1651, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37268274

RESUMO

OBJECTIVE: To determine the interrater reliability of the Scale for the Assessment and Rating of Ataxia (SARA), Berg Balance Scale (BBS), and motor domain of the FIM (m-FIM) administered by physiotherapists in individuals with a hereditary cerebellar ataxia (HCA). DESIGN: Participants were assessed by 1 of 4 physiotherapists. Assessments were video-recorded and the remaining 3 physiotherapists scored the scales for each participant. Raters were blinded to each other's scores. SETTING: Assessments were administered at 3 clinical locations in separate states in Australia. PARTICIPANTS: Twenty-one individuals (mean age=47.63 years; SD=18.42; 13 male and 8 female) living in the community with an HCA were recruited (N=21). MAIN OUTCOME MEASURES: Total and single-item scores of the SARA, BBS, and m-FIM were examined. The m-FIM was conducted by interview. RESULTS: Intraclass coefficients (2,1) for the total scores of the m-FIM (0.92; 95% confidence interval [CI], 0.85-0.96), SARA (0.92; 95% CI, 0.86-0.96), and BBS (0.99; 95% CI, 0.98-0.99) indicated excellent interrater reliability. However, there was inconsistent agreement with the individual items, with SARA item 5 (right side) and item 7 (both sides) demonstrating poor interrater reliability and items 1 and 2 demonstrating excellent reliability. CONCLUSIONS: The m-FIM (by interview), SARA, and BBS have excellent interrater reliability for use when assessing individuals with an HCA. Physiotherapists could be considered for administration of the SARA in clinical trials. However, further work is required to improve the agreement of the single-item scores and to examine the other psychometric properties of these scales.


Assuntos
Ataxia Cerebelar , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Ataxia Cerebelar/reabilitação , Reprodutibilidade dos Testes , Estado Funcional , Avaliação da Deficiência , Psicometria , Equilíbrio Postural
9.
Circulation ; 147(21): 1594-1605, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-37154049

RESUMO

BACKGROUND: In patients with severe symptomatic aortic stenosis at low surgical risk, transfemoral transcatheter aortic valve replacement (TAVR) with the SAPIEN 3 valve has been shown to reduce the composite of death, stroke, or rehospitalization at 2-year follow-up compared with surgical aortic valve replacement (SAVR). Whether TAVR is cost-effective compared with SAVR for low-risk patients remains uncertain. METHODS: Between 2016 and 2017, 1000 low-risk patients with aortic stenosis were randomly assigned to TAVR with the SAPIEN 3 valve or SAVR in the PARTNER 3 trial (Placement of Aortic Transcatheter Valves). Of these patients, 929 underwent valve replacement, were enrolled in the United States, and were included in the economic substudy. Procedural costs were estimated using measured resource use. Other costs were determined by linkage with Medicare claims or by regression models when linkage was not feasible. Health utilities were estimated using the EuroQOL 5-item questionnaire. With the use of a Markov model informed by in-trial data, lifetime cost-effectiveness from the perspective of the US health care system was estimated in terms of cost per quality-adjusted life-year gained. RESULTS: Although procedural costs were nearly $19 000 higher with TAVR, total index hospitalization costs were only $591 more with TAVR compared with SAVR. Follow-up costs were lower with TAVR such that TAVR led to 2-year cost savings of $2030/patient compared with SAVR (95% CI, -$6222 to $1816) and a gain of 0.05 quality-adjusted life-years (95% CI, -0.003 to 0.102). In our base-case analysis, TAVR was projected to be an economically dominant strategy with a 95% probability that the incremental cost-effectiveness ratio for TAVR would be <$50 000/quality-adjusted life-year gained (consistent with high economic value from a US health care perspective). These findings were sensitive to differences in long-term survival, however, such that a modest long-term survival advantage with SAVR would render SAVR cost-effective (although not cost saving) compared with TAVR. CONCLUSIONS: For patients with severe aortic stenosis and low surgical risk similar to those enrolled in the PARTNER 3 trial, transfemoral TAVR with the SAPIEN 3 valve is cost saving compared with SAVR at 2 years and is projected to be economically attractive in the long run as long as there are no substantial differences in late death between the 2 strategies. Long-term follow-up will be critical to ultimately determine the preferred treatment strategy for low-risk patients from both a clinical and economic perspective.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Estados Unidos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Medicare , Substituição da Valva Aórtica Transcateter/métodos , Fatores de Risco
10.
Ann Am Thorac Soc ; 20(4): 491-498, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37000144

RESUMO

Mechanically ventilated patients experience many adverse symptoms, such as anxiety, thirst, and dyspnea. However, these common symptoms are not included in practice guideline recommendations for routine assessment of mechanically ventilated patients. An American Thoracic Society-sponsored workshop with researchers and clinicians with expertise in critical care and symptom management was convened for a discussion of symptom assessment in mechanically ventilated patients. Members included nurses, physicians, a respiratory therapist, a speech-language pathologist, a critical care pharmacist, and a former intensive care unit patient. This report summarizes existing evidence and consensus among workshop participants regarding 1) symptoms that should be considered for routine assessment of adult patients receiving mechanical ventilation; 2) key symptom assessment principles; 3) strategies that support symptom assessment in nonvocal patients; and 4) areas for future clinical practice development and research. Systematic patient-centered assessment of multiple symptoms has great potential to minimize patient distress and improve the patient experience. A culture shift is necessary to promote ongoing holistic symptom assessment with valid and reliable instruments. This report represents our workgroup consensus on symptom assessment for mechanically ventilated patients. Future work should address how holistic, patient-centered symptom assessment can be embedded into clinical practice.


Assuntos
Cuidados Críticos , Respiração Artificial , Adulto , Humanos , Estados Unidos , Respiração Artificial/efeitos adversos , Avaliação de Sintomas , Sociedades , Ansiedade/diagnóstico , Ansiedade/etiologia , Unidades de Terapia Intensiva
11.
J Comput Chem ; 44(13): 1250-1262, 2023 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-36847779

RESUMO

The nucleation of sulfuric acid-water clusters is a significant contribution to the formation of aerosols as precursors of cloud condensation nuclei (CCN). Depending on the temperature, there is an interplay between the clustering of particles and their evaporation controlling the efficiency of cluster growth. For typical temperatures in the atmosphere, the evaporation of H2 SO4 H2 O clusters is more efficient than the clustering of the first, small clusters, and thus their growth is dampened at its early stages. Since the evaporation rates of small clusters containing an HSO 4 - ion are much smaller than for purely neutral sulfuric acid clusters, they can serve as a central body for the further attachment of H2 SO4 H2 O molecules. We here present an innovative Monte Carlo model to study the growth of aqueous sulfuric acid clusters around central ions. Unlike classical thermodynamic nucleation theory or kinetic models, this model allows to trace individual particles and thus to determine properties for each individual particle. As a benchmarking case, we have performed simulations at T = 300 K a relative humidity of 50% with dipole and ion concentrations of c dipole = 5 × 10 8 - 10 9 cm - 3 and c ion = 0 - 10 7 cm - 3 . We discuss the runtime of our simulations and present the velocity distribution of ionic clusters, the size distribution of the clusters as well as the formation rate of clusters with radii R ≥ 0.85 nm . Simulations give reasonable velocity and size distributions and there is a good agreement of the formation rates with previous results, including the relevance of ions for the initial growth of sulfuric acid-water clusters. Conclusively, we present a computational method which allows studying detailed particle properties during the growth of aerosols as a precursor of CCN.

12.
Int J Speech Lang Pathol ; 25(1): 68-71, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36345895

RESUMO

PURPOSE: Sepsis is a major global health problem with an estimated 49 million cases globally each year causing as many as 11 million deaths. The primary objective of this commentary is to describe the impacts of sepsis and critical illness on communication and swallowing function, and to discuss management strategies considering the Sustainable Development Goals (SDGs). RESULT: Communication and swallowing disabilities can occur with sepsis and critical illness. A holistic framework to optimise function, recovery, and future research priorities across the lifespan can be developed through the SDGs. CONCLUSION: Communication and swallowing disabilities following critical illness associated with sepsis have global impacts. Early multidisciplinary engagement is key to optimising individuals' function. Collaborative research, education, and public awareness is urgently needed to increase equity in health outcomes across populations. This commentary paper supports progress towards good health and well-being (SDG 3), quality education (SDG 4) and reduced inequalities (SDG 10).


Assuntos
Sepse , Desenvolvimento Sustentável , Humanos , Estado Terminal , Deglutição , Objetivos , Comunicação , Sepse/complicações , Sepse/terapia
13.
J Pers Med ; 12(11)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36579509

RESUMO

Reproductive genetic carrier screening (RGCS) provides people with information about their chance of having children with autosomal recessive or X-linked genetic conditions, enabling informed reproductive decision-making. RGCS is recommended to be offered to all couples during preconception or in early pregnancy. However, cost and a lack of awareness may prevent access. To address this, the Australian Government funded Mackenzie's Mission­the Australian Reproductive Genetic Carrier Screening Project. Mackenzie's Mission aims to assess the acceptability and feasibility of an easily accessible RGCS program, provided free of charge to the participant. In study Phase 1, implementation needs were mapped, and key study elements were developed. In Phase 2, RGCS is being offered by healthcare providers educated by the study team. Reproductive couples who provide consent are screened for over 1200 genes associated with >750 serious, childhood-onset genetic conditions. Those with an increased chance result are provided comprehensive genetic counseling support. Reproductive couples, recruiting healthcare providers, and study team members are also invited to complete surveys and/or interviews. In Phase 3, a mixed-methods analysis will be undertaken to assess the program outcomes, psychosocial implications and implementation considerations alongside an ongoing bioethical analysis and a health economic evaluation. Findings will inform the implementation of an ethically robust RGCS program.

14.
Eur J Hum Genet ; 30(11): 1262-1268, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35902697

RESUMO

Australian life insurance companies can legally use genetic test results in underwriting, which can lead to genetic discrimination. In 2019, the Financial Services Council (Australian life insurance industry governing body) introduced a partial moratorium restricting the use of genetic testing in underwriting policies ≤ $500,000 (active 2019-2024). Health professionals (HPs), especially clinical geneticists and genetic counsellors, often discuss the implications of genetic testing with patients, and provide critical insights into the effectiveness of the moratorium. Using a sequential explanatory mixed methods design, we interviewed 23 Australian HPs, who regularly discuss genetic testing with patients and had previously completed an online survey about genetic testing and life insurance. Interviews explored views and experiences about the moratorium, and regulation, in greater depth. Interview transcripts were analysed using thematic analysis. Two key themes emerged from views expressed by HPs during interviews (about matters reported to or observed by them): 1) benefits of the moratorium, and 2) concerns about the moratorium. While HPs reported that the moratorium reassures some consumers, concerns include industry self-regulation, uncertainty created by the temporary time period, and the inadequacy of the moratorium's financial limits for patients' financial needs. Although a minority of HPs felt the current industry self-regulated moratorium is an adequate solution to genetic discrimination, the vast majority (19/23) expressed concern with industry self-regulation and most felt government regulation is required to adequately protect consumers. HPs in Australia are concerned about the adequacy of the FSC moratorium with regards to consumer protections, and suggest government regulation is required.


Assuntos
Testes Genéticos , Seguro de Vida , Humanos , Austrália , Pesquisa Qualitativa , Pessoal de Saúde
15.
Ann Thorac Surg ; 113(5): 1730-1742, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35367049

RESUMO

Transcatheter aortic valve replacement (TAVR) is the standard of care for severe, symptomatic aortic stenosis. Real-world TAVR data collection contributes to benefit/risk assessment and safety evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, as well as clinical research and real-world implementation through appropriate use criteria. The essential minimum core dataset for these purposes has not previously been defined but is necessary to promote efficient, reusable real-world data collection supporting quality, regulatory, and clinical applications. The authors performed a systematic review of the published research for high-impact TAVR studies and U.S. multicenter, multidevice registries. Two expert task forces, one from the Predictable and Sustainable Implementation of National Cardiovascular Registries/Heart Valve Collaboratory and another from The Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry convened separately and then met to reconcile a final list of essential data elements. From 276 unique data elements considered, unanimous consensus agreement was achieved on 132 "core" data elements, with the most common reasons for exclusion from the minimum core dataset being burden or difficulty in accurate assessment (36.9%), duplicative information (33.3%), and low likelihood of affecting outcomes (10.7%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established 132 interoperable, reusable essential core data elements essential to supporting more efficient, consistent, and informative TAVR device evidence for regulatory submissions, safety surveillance, best practice, and hospital quality assessments.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Medicare , Estudos Multicêntricos como Assunto , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
16.
JACC Cardiovasc Interv ; 15(7): 685-697, 2022 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-35367168

RESUMO

Transcatheter aortic valve replacement (TAVR) is the standard of care for severe, symptomatic aortic stenosis. Real-world TAVR data collection contributes to benefit/risk assessment and safety evidence for the U.S. Food and Drug Administration, quality evaluation for the Centers for Medicare and Medicaid Services and hospitals, as well as clinical research and real-world implementation through appropriate use criteria. The essential minimum core dataset for these purposes has not previously been defined but is necessary to promote efficient, reusable real-world data collection supporting quality, regulatory, and clinical applications. The authors performed a systematic review of the published research for high-impact TAVR studies and U.S. multicenter, multidevice registries. Two expert task forces, one from the Predictable and Sustainable Implementation of National Cardiovascular Registries/Heart Valve Collaboratory and another from The Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry convened separately and then met to reconcile a final list of essential data elements. From 276 unique data elements considered, unanimous consensus agreement was achieved on 132 "core" data elements, with the most common reasons for exclusion from the minimum core dataset being burden or difficulty in accurate assessment (36.9%), duplicative information (33.3%), and low likelihood of affecting outcomes (10.7%). After a systematic review and extensive discussions, a multilateral group of academicians, industry representatives, and regulators established 132 interoperable, reusable essential core data elements essential to supporting more efficient, consistent, and informative TAVR device evidence for regulatory submissions, safety surveillance, best practice, and hospital quality assessments.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Medicare , Estudos Multicêntricos como Assunto , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos
17.
Drugs ; 82(2): 97-108, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34932209

RESUMO

Chronic kidney disease (CKD) is a serious, progressive condition associated with significant patient morbidity. Hypertension control and use of renin-angiotensin system blockers are the cornerstones of treatment for CKD. However, even with these treatment strategies, many individuals will progress towards kidney failure. Recently, sodium-glucose cotransporter 2 (SGLT2) inhibitor clinical trials with primary renal endpoints have firmly established SGLT2 inhibition, in addition to standard of care, as an effective strategy to slow down the progression of CKD and reduce some of its associated complications. The emergence of this new clinical evidence supports the use of SGLT2 inhibitors in the management of CKD in people with and without diabetes. As licensing and guidelines for SGLT2 inhibitors are updated, there is a need to adapt CKD treatment pathways and for this class of drugs to be included as part of standard care for CKD management. In this article, we have used consensus opinion alongside the available evidence to provide support for the healthcare community involved in CKD management, regarding the role of SGLT2 inhibitors in clinical practice. By highlighting appropriate prescribing and practical considerations, we aim to encourage greater and safe use of SGLT2 inhibitors for people with CKD, both with and without diabetes.


Assuntos
Insuficiência Renal Crônica/tratamento farmacológico , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico , Nefropatias Diabéticas/tratamento farmacológico , Humanos , Estudos Multicêntricos como Assunto , Guias de Prática Clínica como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Insuficiência Renal Crônica/economia , Transportador 1 de Glucose-Sódio/antagonistas & inibidores , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Inibidores do Transportador 2 de Sódio-Glicose/economia
18.
Circ Cardiovasc Interv ; 14(11): e009374, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34784236

RESUMO

BACKGROUND: Women have a higher rate of adverse events after mitral valve surgery. We sought to evaluate whether outcomes after transcatheter edge-to-edge repair intervention by sex have similar trends to mitral valve surgery. METHODS: The primary outcome was 1-year major adverse events defined as a composite of all-cause mortality, stroke, and any bleeding in the overall study cohort. Patients who underwent transcatheter edge-to-edge repair for mitral regurgitation with the MitraClip system in the Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy registry were evaluated. Linked administrative claims from the Centers for Medicare and Medicaid Services were used to evaluate 1-year clinical outcomes. Associations between sex and outcomes were evaluated using a multivariable logistic regression model for in-hospital outcomes and Cox model for 1-year outcomes. RESULTS: From November 2013 to March 2017, 5295 patients, 47.6% (n=2523) of whom were female, underwent transcatheter edge-to-edge repair. Females were less likely to have >1 clip implanted (P<0.001) and had a lower adjusted odds ratio of device success (adjusted odds ratio, 0.78 [95% CI, 0.67-0.90]), driven by lower odds of residual mitral gradient <5 mm Hg (adjusted odds ratio, 0.54 [CI, 0.46-0.63]) when compared with males. At 1-year follow-up, the primary outcome did not differ by sex. Female sex was associated with lower adjusted 1-year risk of all-cause mortality (adjusted hazard ratio, 0.80 [CI, 0.68-0.94]), but the adjusted 1-year risk of stroke and any bleeding did not differ by sex. CONCLUSIONS: No difference in composite outcome of all-cause mortality, stroke, and any bleeding was observed between females and males. Adjusted 1-year all-cause mortality was lower in females compared with males.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Medicare , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Sistema de Registros , Resultado do Tratamento , Estados Unidos/epidemiologia
19.
J Am Coll Cardiol ; 78(22): 2161-2172, 2021 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-34823659

RESUMO

BACKGROUND: Recent trends, including survival beyond 30 days, in aortic valve replacement (AVR) following the expansion of indications for transcatheter aortic valve replacement (TAVR) are not well-understood. OBJECTIVES: The authors sought to characterize the trends in characteristics and outcomes of patients undergoing AVR. METHODS: The authors analyzed Medicare beneficiaries who underwent TAVR and SAVR in 2012 to 2019. They evaluated case volume, demographics, comorbidities, 1-year mortality, and discharge disposition. Cox proportional hazard models were used to assess the annual change in outcomes. RESULTS: Per 100,000 beneficiary-years, AVR increased from 107 to 156, TAVR increased from 19 to 101, whereas SAVR declined from 88 to 54. The median [interquartile range] age remained similar from 77 [71-83] years to 78 [72-84] years for overall AVR, decreased from 84 [79-88] years to 81 [75-86] years for TAVR, and decreased from 76 [71-81] years to 72 [68-77] years for SAVR. For all AVR patients, the prevalence of comorbidities remained relatively stable. The 1-year mortality for all AVR decreased from 11.9% to 9.4%. Annual change in the adjusted odds of 1-year mortality was 0.93 (95% CI: 0.92-0.94) for TAVR and 0.98 (95% CI: 0.97-0.99) for SAVR, and 0.94 (95% CI: 0.93-0.95) for all AVR. Patients discharged to home after AVR increased from 24.2% to 54.7%, primarily driven by increasing home discharge after TAVR. CONCLUSIONS: The advent of TAVR has led to about a 60% increase in overall AVR in older adults. Improving outcomes in AVR as a whole following the advent of TAVR with increased access is a reassuring trend.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Medicare/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Estados Unidos/epidemiologia
20.
Aust J Gen Pract ; 50(8): 538-544, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34333565

RESUMO

BACKGROUND AND OBJECTIVES: Discussing population-based cancer risk and screening is common in general practice. Patients with an inherited cancer syndrome, however, may need more nuanced discussions. Li-Fraumeni syndrome (LFS) is a rare, inherited cancer syndrome that affects many organ systems from birth and requires intensive, whole-body cancer risk management. The aim of this study was to explore the risk management experiences of young people (aged 15-39 years) with, or at risk of, LFS. METHOD: Using an interpretive description design, semi-structured interviews were conducted with young people diagnosed with, or at risk of, LFS from across Australia. Interview transcripts were analysed with team-based, codebook thematic analysis. RESULTS: Thirty young people (mean age 25.5 years) participated. Participants described intensive screening and risk-reducing mastectomy (for women) as their 'best shot' to control their cancer risks with LFS. Engaging in these options as a young person came with a slew of psychosocial implications. DISCUSSION: General practitioners may help to improve care for young people with inherited cancer syndromes by acknowledging the benefits and complex burdens of their risk management.


Assuntos
Neoplasias da Mama , Síndrome de Li-Fraumeni , Adolescente , Adulto , Feminino , Humanos , Síndrome de Li-Fraumeni/genética , Programas de Rastreamento , Mastectomia , Gestão de Riscos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA