Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Am Coll Cardiol ; 79(2): 166-179, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-35027110

RESUMO

The prevalence of atrial fibrillation (AF) is increasing as the population ages. AF treatment-related complications also increase markedly in older adults (defined as ≥75 years of age for this review). The older AF population has a high risk of stroke, bleeding, and death. Syncope and fall-related injuries are the most common reasons for nonprescription of oral anticoagulation (OAC), and are more common in older adults when OACs are used with antiarrhythmic drugs. Digoxin may be useful for rate control, but associations with increased mortality limit its use. Beyond rate and rhythm control considerations, stroke prophylaxis is critical to AF management, and the benefits of direct OACs, compared with warfarin, extend to older adults. Invasive procedures such as AF catheter ablation, pacemaker implantation/atrioventricular junction ablation, and left atrial appendage occlusion may be useful in appropriately selected cases. However, older adults have generally been under-represented in clinical trials.


Assuntos
Fibrilação Atrial/terapia , Acidentes por Quedas/prevenção & controle , Idoso , Consumo de Bebidas Alcoólicas/efeitos adversos , Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Apêndice Atrial/cirurgia , Ablação por Cateter , Disfunção Cognitiva/complicações , Doença da Artéria Coronariana/terapia , Análise Custo-Benefício , Tomada de Decisão Compartilhada , Demência/complicações , Diabetes Mellitus/terapia , Terapia Antiplaquetária Dupla , Exercício Físico , Fragilidade , Insuficiência Cardíaca/terapia , Humanos , Hipertensão/terapia , Sobrepeso/prevenção & controle , Polimedicação , Prevenção Primária , Medição de Risco , Prevenção Secundária , Apneia Obstrutiva do Sono/terapia , Acidente Vascular Cerebral/prevenção & controle , Vitamina K/antagonistas & inibidores , Redução de Peso
2.
JACC Cardiovasc Imaging ; 14(12): 2369-2383, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34419391

RESUMO

OBJECTIVES: The objective was to determine the feasibility and effectiveness of cardiac magnetic resonance (CMR) cine and strain imaging before and after cardiac resynchronization therapy (CRT) for assessment of response and the optimal resynchronization pacing strategy. BACKGROUND: CMR with cardiac implantable electronic devices can safely provide high-quality right ventricular/left ventricular (LV) ejection fraction (RVEF/LVEF) assessments and strain. METHODS: CMR with cine imaging, displacement encoding with stimulated echoes for the circumferential uniformity ratio estimate with singular value decomposition (CURE-SVD) dyssynchrony parameter, and scar assessment was performed before and after CRT. Whereas the pre-CRT scan constituted a single "imaging set" with complete volumetric, strain, and scar imaging, multiple imaging sets with complete strain and volumetric data were obtained during the post-CRT scan for biventricular pacing (BIVP), LV pacing (LVP), and asynchronous atrial pacing modes by reprogramming the device outside the scanner between imaging sets. RESULTS: 100 CMRs with a total of 162 imaging sets were performed in 50 patients (median age 70 years [IQR: 50-86 years]; 48% female). Reduction in LV end-diastolic volumes (P = 0.002) independent of CRT pacing were more prominent than corresponding reductions in right ventricular end-diastolic volumes (P = 0.16). A clear dependence of the optimal CRT pacing mode (BIVP vs LVP) on the PR interval (P = 0.0006) was demonstrated. The LVEF and RVEF improved more with BIVP than LVP with PR intervals ≥240 milliseconds (P = 0.025 and P = 0.002, respectively); the optimal mode (BIVP vs LVP) was variable with PR intervals <240 milliseconds. A lower pre-CRT displacement encoding with stimulated echoes (DENSE) CURE-SVD was associated with greater improvements in the post-CRT CURE-SVD (r = -0.69; P < 0.001), LV end-systolic volume (r = -0.58; P < 0.001), and LVEF (r = -0.52; P < 0.001). CONCLUSIONS: CMR evaluation with assessment of multiple pacing modes during a single scan after CRT is feasible and provides useful information for patient care with respect to response and the optimal pacing strategy.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Idoso , Terapia de Ressincronização Cardíaca/métodos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Valor Preditivo dos Testes , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
3.
J Interv Card Electrophysiol ; 56(2): 143-150, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30117010

RESUMO

The system for graduate medical education (GME) in the USA is vital to maintaining a well-trained physician population to meet the needs of the nation. The funding of this system over the last several decades has been complicated, and the government's role in funding GME is controversial. In this paper, the current mechanisms for funding residency and fellowship training are outlined as well as proposed changes to system. The current system has made funding electrophysiology training difficult, and the proposed changes have profound implications. It is important for the electrophysiology community to be educated and advocate for electrophysiology fellowship training such that Americans continue to have appropriate access to arrhythmia care.


Assuntos
Eletrofisiologia Cardíaca/educação , Educação de Pós-Graduação em Medicina/economia , Modelos Econômicos , Bolsas de Estudo , Humanos , Internato e Residência , Qualidade da Assistência à Saúde , Estados Unidos
5.
Proc Nutr Soc ; 77(3): 331-346, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29198210

RESUMO

The objective of the present paper is to draw lessons from policy development on sustainable diets. It considers the emergence of sustainable diets as a policy issue and reviews the environmental challenge to nutrition science as to what a 'good' diet is for contemporary policy. It explores the variations in how sustainable diets have been approached by policy-makers. The paper considers how international United Nations and European Union (EU) policy engagement now centres on the 2015 Sustainable Development Goals and Paris Climate Change Accord, which require changes across food systems. The paper outlines national sustainable diet policy in various countries: Australia, Brazil, France, the Netherlands, Qatar, Sweden, UK and USA. While no overarching common framework for sustainable diets has appeared, a policy typology of lessons for sustainable diets is proposed, differentiating (a) orientation and focus, (b) engagement styles and (c) modes of leadership. The paper considers the particularly tortuous rise and fall of UK governmental interest in sustainable diet advice. Initial engagement in the 2000s turned to disengagement in the 2010s, yet some advice has emerged. The 2016 referendum to leave the EU has created a new period of policy uncertainty for the UK food system. This might marginalise attempts to generate sustainable diet advice, but could also be an opportunity for sustainable diets to be a goal for a sustainable UK food system. The role of nutritionists and other food science professions will be significant in this period of policy flux.


Assuntos
Conservação dos Recursos Naturais , Dieta , Comportamento Alimentar , Abastecimento de Alimentos , Política Nutricional , América , Austrália , Europa (Continente) , Tecnologia de Alimentos , Governo , Humanos , Liderança , Formulação de Políticas , Catar
6.
Curr Opin Cardiol ; 31(1): 57-63, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26599059

RESUMO

PURPOSE OF REVIEW: The prevalence of atrial fibrillation is increasing and surgical ablation is becoming more common, both as a stand-alone procedure and when performed concomitantly with other cardiac surgery. Although surgical ablation is effective, with it unique challenges arise, including iatrogenic macroreentrant tachycardias that are often highly symptomatic and difficult to manage conservatively. RECENT FINDINGS: Postsurgical ablation, localization of the arrhythmic circuit is difficult to determine using surface ECG alone because of alterations in the atrial myocardium, and multiple different pathways are often present. Most, however, localize to the left atrium, and percutaneous catheter ablation is emerging as an effective treatment modality. SUMMARY: Patients with complex postoperative arrhythmias should be referred to a dedicated atrial fibrillation center when possible and symptomatic arrhythmias mapped and ablated. Knowledge of the previously performed surgical lesion set is of vital importance in understanding the mechanism of the arrhythmia and increasing procedural success rates. VIDEO ABSTRACT: http://links.lww.com/HCO/A31.


Assuntos
Fibrilação Atrial , Ablação por Cateter/métodos , Gerenciamento Clínico , Eletrocardiografia , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Operatórios/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Flutter Atrial , Saúde Global , Humanos , Incidência
7.
Am J Cardiol ; 115(2): 206-8, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25479754

RESUMO

Riata and Riata ST defibrillator leads (St. Jude Medical, Sylmar, California) were recalled in 2011 due to increased risk of insulation failure leading to externalized cables. Fluoroscopic screening can identify insulation failure, although the relation between mechanical failure and electrical failure is unclear. At the time of the recall, the University of Virginia developed a screening program, including fluoroscopic evaluation, education sessions, device interrogation, and remote monitoring for patients with this defibrillator lead. The aim of this study was to review the outcomes of the screening program, including costs, which were absorbed by our institution. Costs were calculated using Medicare reimbursement estimates. Forty-eight patients participated in the screening program. At initial screening, 31% were found to have evidence of insulation failure but electrical function was normal in all leads. The cost of this program was $35,358.72. The cost per diagnosis of mechanical lead failure was $2,357.25. During 2 years of follow-up, 1 patient experienced Riata lead electrical failure without fluoroscopic evidence of insulation failure. Patients were more likely to have a lead revision if there was evidence of insulation failure. Lead revisions occurred at the time of generator change in 88% of patients with insulation failure but in only 14% of patients with a fluoroscopically normal lead (p = 0.04). The cost of recall-related defibrillator lead revisions was $81,704.55. In conclusion, our Riata screening program added expense without clear benefit to patients. In fact, patients may have been put at more risk by undergoing defibrillator lead revisions based solely on the results of the fluoroscopic screening.


Assuntos
Desfibriladores Implantáveis/economia , Recall de Dispositivo Médico , Custos e Análise de Custo , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Retrospectivos , Estados Unidos , United States Food and Drug Administration
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA