Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Asian J Endosc Surg ; 17(2): e13288, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38355100

RESUMO

Surgical treatment of celiac artery (CA) compression syndrome (CACS) is to release the median arcuate ligament (MAL) by removing the abdominal nerve plexus surrounding CA. In laparoscopic surgery of CACS, objective intraoperative assessment of blood flow in CA is highly desirable. We herein demonstrate a case of laparoscopic surgery of CACS with use of intraoperative transabdominal ultrasound. A 52-year-old woman was presented with epigastric pain and vomiting after eating. Contrast-enhanced computed tomography demonstrated significant stenosis at the origin of CA. Doppler study of CA was also performed, and she was diagnosed as CACS. Laparoscopic surgery was performed, and the MAL was divided. And then, Doppler study using intraoperative transabdominal ultrasound confirmed the successful decompression of CA. This patient was discharged on postoperative day 11, and her symptoms was improved. Intraoperative assessment of blood flow in CA using transabdominal ultrasound was a simple and useful method for laparoscopic surgery of CACS.


Assuntos
Arteriopatias Oclusivas , Laparoscopia , Síndrome do Ligamento Arqueado Mediano , Feminino , Humanos , Pessoa de Meia-Idade , Síndrome do Ligamento Arqueado Mediano/diagnóstico por imagem , Síndrome do Ligamento Arqueado Mediano/cirurgia , Artéria Celíaca/diagnóstico por imagem , Artéria Celíaca/cirurgia , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/cirurgia , Descompressão Cirúrgica/métodos , Laparoscopia/métodos
2.
Ann Gastroenterol Surg ; 7(3): 430-440, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37152778

RESUMO

Aim: The current study compared the postoperative quality of life (QOL) between the esophagogastrostomy method (PGEG) and double tract method (PGDT) after proximal gastrectomy using the Postgastretomy Syndrome Assessment Scale (PGSAS)-45. Methods: Among the 2364 patients who received the PGSAS-45 questionnaire, 300 PGEG and 172 PGDT cases responded. The main outcomes measures (MOMs) consisted of seven subscales (SS) covering symptoms, meals (amount and quality), ability to work, dissatisfaction with daily life, physical and mental component summary of the 8-Item Short Form Health Survey (SF-8), and change in body weight, and were compared between PGEG and PGDT. Results: Overall, PGDT promoted significantly better constipation SS scores (p < 0.05), whereas PGEG tended to promote better body weight (BW) loss% (p < 0.10). A stratified analysis based on the remnant stomach size revealed that among those with a remnant stomach size of 1/2, PGDT had significantly better constipation and dumping SS scores (p < 0.05) and tended to have better working conditions (p < 0.10) compared to PGEG. Even among those with the remnant stomach size of 2/3, PGDT had significantly better diarrhea SS scores, lesser dissatisfaction with symptoms, and better dissatisfaction with daily life SS scores (p < 0.05) and tended to have better constipation SS scores and lesser dissatisfaction with work (p < 0.10) compared to PGEG. Conclusions: After comparing the QOLs of PGEG and PGDT, the stratified analysis according to remnant stomach sizes of 1/2 and 2/3 revealed that PGDT was relatively superior to PGEG for several MOMs.

3.
World J Gastrointest Endosc ; 10(11): 340-347, 2018 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-30487944

RESUMO

AIM: To investigate that polysomnographic monitoring can accurately evaluate respiratory disturbance incidence during sedation for gastrointestinal endoscopy compare to pulse oximetry alone. METHODS: This prospective observational study included 10 elderly patients with early gastric cancer undergoing endoscopic submucosal dissection (ESD) under propofol sedation. Apart from routine cardiorespiratory monitoring, polysomnography measurements were acquired. The primary hypothesis was tested by comparing the apnea hypopnea index (AHI), defined as the number of apnea and hypopnea instances per hour during sedation, with and without hypoxemia; hypoxemia was defined as the reduction in oxygen saturation by ≥ 3% from baseline. RESULTS: Polysomnography (PSG) detected 207 respiratory disturbances in the 10 patients. PSG yielded a significantly greater AHI (10.44 ± 5.68/h) compared with pulse oximetry (1.54 ± 1.81/h, P < 0.001), thus supporting our hypothesis. Obstructive AHI (9.26 ± 5.44/h) was significantly greater than central AHI (1.19 ± 0.90/h, P < 0.001). Compared with pulse oximetry, PSG detected the 25 instances of respiratory disturbances with hypoxemia 107.4 s earlier on average. CONCLUSION: Compared with pulse oximetry, PSG can better detect respiratory irregularities and thus provide superior AHI values, leading to avoidance of fatal respiratory complications during ESD under propofol-induced sedation.

4.
Esophagus ; 13: 254-263, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27429608

RESUMO

BACKGROUND: We performed endoscopic ultrasound real-time tissue elastography to more accurately diagnose lymph node metastasis of esophageal cancer. The aim of this study was to evaluate the ability of EUS elastography to distinguish benign from malignant lymph nodes in esophageal cancer patients. METHODS: The present study had two steps. As the first step (study 1), we developed diagnostic criteria for metastatic lymph nodes using elastography and verified the validity of the criteria. Three hundred and twenty-two lymph nodes from 35 patients treated by surgical resection were included in the study. As the second step (study 2), we preoperatively examined the lymph nodes of esophageal cancer patients with EUS elastography and compared its diagnostic performance with that of the conventional B-mode EUS images. A total of 115 lymph nodes from 31 patients were included. RESULTS: In study 1, lymph nodes were considered malignant if 50 % or more of the node appeared blue, or if the peripheral part of the lesion was blue and the central part was red/yellow/green. The sensitivity and specificity of the elastography were 79.7 and 97.6 % with an accuracy of 93.8 %, which was significantly higher than the values for conventional B-mode imaging. In study 2, the sensitivity and specificity of the EUS elastography were 91.2 and 94.5 % with an accuracy of 93.9 %, which was also significantly higher than the values for conventional B-mode EUS imaging. CONCLUSIONS: The present study demonstrated that EUS elastography is useful for diagnosing lymph node metastasis of esophageal cancer.

5.
J Surg Educ ; 72(5): 795-802, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26002537

RESUMO

OBJECTIVE: Although laparoscopic surgery has become widespread, effective and efficient education in laparoscopic surgery is difficult. Instructive laparoscopy videos with appropriate annotations are ideal for initial training in laparoscopic surgery; however, the method we use at our institution for creating laparoscopy videos with audio is not generalized, and there have been no detailed explanations of any such method. Our objectives were to demonstrate the feasibility of low-cost simple methods for recording surgical videos with audio and to perform a preliminary safety evaluation when obtaining these recordings during operations. DESIGN: We devised a method for the synchronous recording of surgical video with real-time audio in which we connected an amplifier and a wireless microphone to an existing endoscopy system and its equipped video-recording device. We tested this system in 209 cases of laparoscopic surgery in operating rooms between August 2010 and July 2011 and prospectively investigated the results of the audiovisual recording method and examined intraoperative problems. SETTING: Numazu City Hospital in Numazu city, Japan. PARTICIPANTS: Surgeons, instrument nurses, and medical engineers. RESULTS: In all cases, the synchronous input of audio and video was possible. The recording system did not cause any inconvenience to the surgeon, assistants, instrument nurse, sterilized equipment, or electrical medical equipment. Statistically significant differences were not observed between the audiovisual group and control group regarding the operating time, which had been divided into 2 slots-performed by the instructors or by trainees (p > 0.05). CONCLUSIONS: This recording method is feasible and considerably safe while posing minimal difficulty in terms of technology, time, and expense. We recommend this method for both surgical trainees who wish to acquire surgical skills effectively and medical instructors who wish to teach surgical skills effectively.


Assuntos
Recursos Audiovisuais , Laparoscopia/educação , Gravação em Fita , Gravação em Vídeo/métodos , Apendicectomia , Colecistectomia , Sistemas Computacionais , Estudos de Viabilidade , Humanos , Período Intraoperatório , Estudos Prospectivos , Gravação em Vídeo/economia
6.
J Hepatol ; 44(1): 68-75, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16271795

RESUMO

BACKGROUND/AIMS: Ultrasound is noninvasive and useful to evaluate liver disease despite its operator dependency. This pilot study was conducted to quantitatively assess liver fibrosis using ultrasound. METHODS: Fibrosis extraction ratios (FER) (fiber volume/total volume) of ultrasound and histological images of 8 autopsy specimens were compared. We also compared FER of ultrasound images from clinical patients (n=79) with histological fibrosis stages. RESULTS: In the autopsy study, FER correlation coefficient between histological images and ultrasound images was 0.992. Regarding clinical patients, there was sufficient evidence to indicate differences in the distributions of FER for each fibrosis stage (Kruskal-Wallis test P<0.0001). With FER cut-off to distinguish > or =F2 from F0 and F1 defined as mean plus standard deviation of F0 and F1, sensitivity, specificity, positive predictive value, negative predictive value, and likelihood ratio were 62, 75, 78, 57%, and 2.47, respectively. Regarding HCV cohort (n=44), they were 55, 87, 89, 50%, and 4.14, respectively. Areas under receiver operating characteristic curves were 0.78, 0.79, 0.83 and 0.83 for > or =F1, > or =F2, > or =F3 and =F4, respectively. Regarding HCV cohort, they were 0.74, 0.71, 0.79 for > or =F2, > or =3 and =4, respectively. CONCLUSIONS: The FER method has great potential for diagnosing liver fibrosis using ultrasound.


Assuntos
Cirrose Hepática/diagnóstico por imagem , Adulto , Idoso , Autopsia , Biópsia , Progressão da Doença , Feminino , Humanos , Técnicas In Vitro , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Retrospectivos , Índice de Gravidade de Doença , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA