Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Brain ; 142(11): 3440-3455, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31578541

RESUMO

The 18 kDa translocator protein (TSPO) is increasingly used to study brain and spinal cord inflammation in degenerative diseases of the CNS such as multiple sclerosis. The enhanced TSPO PET signal that arises during disease is widely considered to reflect activated pathogenic microglia, although quantitative neuropathological data to support this interpretation have not been available. With the increasing interest in the role of chronic microglial activation in multiple sclerosis, characterising the cellular neuropathology associated with TSPO expression is of clear importance for understanding the cellular and pathological processes on which TSPO PET imaging is reporting. Here we have studied the cellular expression of TSPO and specific binding of two TSPO targeting radioligands (3H-PK11195 and 3H-PBR28) in tissue sections from 42 multiple sclerosis cases and 12 age-matched controls. Markers of homeostatic and reactive microglia, astrocytes, and lymphocytes were used to investigate the phenotypes of cells expressing TSPO. There was an approximate 20-fold increase in cells double positive for TSPO and HLA-DR in active lesions and in the rim of chronic active lesion, relative to normal appearing white matter. TSPO was uniformly expressed across myeloid cells irrespective of their phenotype, rather than being preferentially associated with pro-inflammatory microglia or macrophages. TSPO+ astrocytes were increased up to 7-fold compared to normal-appearing white matter across all lesion subtypes and accounted for 25% of the TSPO+ cells in these lesions. To relate TSPO protein expression to ligand binding, specific binding of the TSPO ligands 3H-PK11195 and 3H-PBR28 was determined in the same lesions. TSPO radioligand binding was increased up to seven times for 3H-PBR28 and up to two times for 3H-PK11195 in active lesions and the centre of chronic active lesions and a strong correlation was found between the radioligand binding signal for both tracers and the number of TSPO+ cells across all of the tissues examined. In summary, in multiple sclerosis, TSPO expression arises from microglia of different phenotypes, rather than being restricted to microglia which express classical pro-inflammatory markers. While the majority of cells expressing TSPO in active lesions or chronic active rims are microglia/macrophages, our findings also emphasize the significant contribution of activated astrocytes, as well as smaller contributions from endothelial cells. These observations establish a quantitative framework for interpretation of TSPO in multiple sclerosis and highlight the need for neuropathological characterization of TSPO expression for the interpretation of TSPO PET in other neurodegenerative disorders.


Assuntos
Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/genética , Receptores de GABA/genética , Acetamidas , Idoso , Idoso de 80 Anos ou mais , Astrócitos/patologia , Autopsia , Feminino , Genótipo , Homeostase , Humanos , Isoquinolinas , Linfócitos/patologia , Masculino , Microglia/patologia , Pessoa de Meia-Idade , Esclerose Múltipla/patologia , Tomografia por Emissão de Pósitrons , Piridinas , Compostos Radiofarmacêuticos
2.
Eur J Prev Cardiol ; 24(17): 1799-1806, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28925747

RESUMO

Background Ultrasound imaging is able to quantify carotid arterial wall structure for the assessment of cerebral and cardiovascular disease risks. We describe a protocol and quality assurance process to enable carotid imaging at large scale that has been developed for the UK Biobank Imaging Enhancement Study of 100,000 individuals. Design An imaging protocol was developed to allow measurement of carotid intima-media thickness from the far wall of both common carotid arteries. Six quality assurance criteria were defined and a web-based interface (Intelligent Ultrasound) was developed to facilitate rapid assessment of images against each criterion. Results and conclusions Excellent inter and intra-observer agreements were obtained for image quality evaluations on a test dataset from 100 individuals. The image quality criteria then were applied in the UK Biobank Imaging Enhancement Study. Data from 2560 participants were evaluated. Feedback of results to the imaging team led to improvement in quality assurance, with quality assurance failures falling from 16.2% in the first two-month period examined to 6.4% in the last. Eighty per cent had all carotid intima-media thickness images graded as of acceptable quality, with at least one image acceptable for 98% of participants. Carotid intima-media thickness measures showed expected associations with increasing age and gender. Carotid imaging can be performed consistently, with semi-automated quality assurance of all scans, in a limited timeframe within a large scale multimodality imaging assessment. Routine feedback of quality control metrics to operators can improve the quality of the data collection.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Espessura Intima-Media Carotídea/normas , Protocolos Clínicos/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Melhoria de Qualidade/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Idoso , Coleta de Dados/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Desenvolvimento de Programas , Avaliação de Programas e Projetos de Saúde , Reprodutibilidade dos Testes , Reino Unido
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 5709-5712, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269551

RESUMO

Long-term electroencephalogram (EEG) is important for seizure detection, sleep monitoring and etc. In-the- ear EEG device makes such recording robust to noise and privacy protected (invisible to other people). However, the state-of-art techniques suffer from various drawbacks such as customization for specific users, manufacturing difficulties and short life cycle. To address these issues, we proposed silvered glass silicone based in-the-ear electrode which can be manufactured using conventional compression moulding. The material and in-the-ear EEG are evaluated separately, showing that the proposed method is durable, low-cost and easy-to-make.


Assuntos
Equipamentos Médicos Duráveis , Meato Acústico Externo , Eletroencefalografia/instrumentação , Desenho de Equipamento , Conforto do Paciente , Eletrodos/economia , Eletroencefalografia/economia , Vidro , Humanos , Silicones , Prata
4.
Proc Natl Acad Sci U S A ; 111(49): 17648-53, 2014 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-25422429

RESUMO

Several theories link processes of development and aging in humans. In neuroscience, one model posits for instance that healthy age-related brain degeneration mirrors development, with the areas of the brain thought to develop later also degenerating earlier. However, intrinsic evidence for such a link between healthy aging and development in brain structure remains elusive. Here, we show that a data-driven analysis of brain structural variation across 484 healthy participants (8-85 y) reveals a largely--but not only--transmodal network whose lifespan pattern of age-related change intrinsically supports this model of mirroring development and aging. We further demonstrate that this network of brain regions, which develops relatively late during adolescence and shows accelerated degeneration in old age compared with the rest of the brain, characterizes areas of heightened vulnerability to unhealthy developmental and aging processes, as exemplified by schizophrenia and Alzheimer's disease, respectively. Specifically, this network, while derived solely from healthy subjects, spatially recapitulates the pattern of brain abnormalities observed in both schizophrenia and Alzheimer's disease. This network is further associated in our large-scale healthy population with intellectual ability and episodic memory, whose impairment contributes to key symptoms of schizophrenia and Alzheimer's disease. Taken together, our results suggest that the common spatial pattern of abnormalities observed in these two disorders, which emerge at opposite ends of the life spectrum, might be influenced by the timing of their separate and distinct pathological processes in disrupting healthy cerebral development and aging, respectively.


Assuntos
Envelhecimento , Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/fisiopatologia , Encéfalo/patologia , Criança , Feminino , Predisposição Genética para Doença , Substância Cinzenta/fisiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Filogenia , Esquizofrenia/fisiopatologia , Software , Adulto Jovem
5.
J Nucl Med ; 55(7): 1112-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24904112

RESUMO

UNLABELLED: PET radioligand binding to the 18-kD translocator protein (TSPO) in the brains of patients with multiple sclerosis (MS) primarily reflects activated microglia and macrophages. We previously developed genetic stratification for accurate quantitative estimation of TSPO using second-generation PET radioligands. In this study, we used (18)F-PBR111 PET and MR imaging to measure relative binding in the lesional, perilesional, and surrounding normal-appearing white matter of MS patients, as an index of the innate immune response. METHODS: (18)F-PBR111 binding was quantified in 11 MS patients and 11 age-matched healthy volunteers, stratified according to the rs6971 TSPO gene polymorphism. Fluid-attenuated inversion recovery and magnetization transfer ratio (MTR) MR imaging were used to segment the white matter in MS patients as lesions, perilesional volumes, nonlesional white matter with reduced MTR, and nonlesional white matter with normal MTR. RESULTS: (18)F-PBR111 binding was higher in the white matter lesions and perilesional volumes of MS patients than in white matter of healthy controls (P < 0.05). Although there was substantial heterogeneity in binding between different lesions, a within-subject analysis showed higher (18)F-PBR111 binding in MS lesions (P < 0.05) and in perilesional (P < 0.05) and nonlesional white matter with reduced MTR (P < 0.005) than in nonlesional white matter with a normal MTR. A positive correlation was observed between the mean (18)F-PBR111 volume of distribution increase in lesions relative to nonlesional white matter with a normal MTR and the MS severity score (Spearman ρ = 0.62, P < 0.05). CONCLUSION: This study demonstrates that quantitative TSPO PET with a second-generation radioligand can be used to characterize innate immune responses in MS in vivo and provides further evidence supporting an association between the white matter TSPO PET signal in lesions and disease severity. Our approach is practical for extension to studies of the role of the innate immune response in MS for differentiation of antiinflammatory effects of new medicines and their longer term impact on clinical outcome.


Assuntos
Esclerose Múltipla/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Piridinas , Substância Branca/diagnóstico por imagem , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Inflamação/diagnóstico por imagem , Macrófagos/imunologia , Masculino , Microglia/patologia , Pessoa de Meia-Idade , Esclerose Múltipla/imunologia , Esclerose Múltipla/patologia , Reprodutibilidade dos Testes , Substância Branca/imunologia , Substância Branca/patologia
6.
Nat Rev Neurol ; 10(1): 15-26, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24323053

RESUMO

Stratified medicine can reduce the costs of neurological care, bringing benefits to both patients and physicians. The availability of routine genetic testing, new biomarkers and advanced imaging, as well as new technologies for patient-centred data collection, has expanded the potential for patient stratification. Several neurology subspecialities, including stroke, epilepsy and behavioural neurology, have already applied stratification for disease prognosis, optimization of disease management and reduction of treatment-related adverse events. Stratification approaches could improve the cost-effectiveness of neurological care that involves treatments with high costs or risks of adverse reactions, as well as guide the use of emerging, highly individualized therapies. There are still major challenges in the development of clinically actionable stratification concepts, and practical barriers can limit adoption of these concepts into clinical practice. However, improved technologies and disease understanding are making more precise stratification practical. We believe that neurologists should become leaders in the development and validation of these practices, and that use of these approaches should be part of a broader strategy for addressing both the growing needs of an ageing population and the rising pressures for rapid improvements in the cost-effectiveness of therapeutics.


Assuntos
Análise Custo-Benefício , Doenças do Sistema Nervoso/diagnóstico , Doenças do Sistema Nervoso/terapia , Neurologia , Medicina de Precisão , Humanos , Prognóstico
7.
Neuroimage ; 27(2): 393-401, 2005 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-15921936

RESUMO

BOLD contrast is the most commonly used functional MRI method for studies of brain activity. However, the underlying physiological processes giving rise to measured BOLD signal changes (which include contribution from changes in cerebral blood flow (CBF), cerebral blood volume (CBV) and cerebral metabolic rate of oxygen consumption (CMRO2)) vary substantially between sessions and subjects. To determine whether direct CBF measurement is a more reliable technique, we compared the localisation of activation and reproducibility of relative signal change measured by optimised BOLD versus CBF measured using the arterial spin labelling (ASL) technique. Data were collected within the primary sensorimotor cortex in normal healthy controls performing a simple finger-tapping task over three imaging sessions (two on same day and one on a different day). The displacement between the foci of BOLD and CBF activation was less than the linear dimension of one voxel (2.4 mm), however, BOLD activation was significantly closer to the nearest draining vein compared to CBF activation (P=0.030). For the relative signal change measurement, we found that CBF has a lower inter-subject variation than BOLD (P<0.05), enabling a smaller sample size for any given effect size, although the intra-subject variation across sessions for CBF was not significantly different from BOLD. BOLD imaging provides the optimal contrast for exploratory brain activation mapping, however, for a single time-point group study, CBF has reduced variance. In addition, the reduction of variance over time using CBF measurements (non-significant) suggests it could potentially provide a more useful approach when assessing longitudinal activation changes.


Assuntos
Circulação Cerebrovascular/fisiologia , Imageamento por Ressonância Magnética/métodos , Oxigênio/sangue , Projetos de Pesquisa , Adulto , Ensaios Clínicos como Assunto , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Individualidade , Masculino , Desempenho Psicomotor/fisiologia , Reprodutibilidade dos Testes , Tamanho da Amostra
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA