Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Ergonomics ; 61(2): 329-338, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28697682

RESUMO

PURPOSE: Identify location and intensity of discomfort experienced by healthy participants wearing cervical orthoses. METHOD: Convenience sample of 34 healthy participants wore Stro II, Philadelphia, Headmaster, and AspenVista® cervical orthoses for four-hour periods. Participants reported discomfort level (scale 0-6) and location. RESULTS: Participants reported mean discomfort for all orthoses over the four-hour test between 'a little discomfort' and 'very uncomfortable' (mean discomfort score = 1.64, SD = 1.50). Seven participants prematurely stopped tests due to pain and six reported maximum discomfort scores. Significant linear increase in discomfort with duration of wear was found for all orthoses. Significantly less discomfort was reported with Stro II than Headmaster and Philadelphia. Age correlated with greater perceived discomfort. Orthoses differed in the location discomfort was experienced. CONCLUSION: Existing cervical orthoses cause discomfort influenced by design and duration of wear with orthoses' design the more significant factor. This work informed the design of a new orthosis and future orthoses developments. Practitioner Summary: The purpose of this study was to gain greater knowledge about the discomfort caused by wearing of existing neck orthoses in order to inform the design and development of a new neck orthosis. This study gathers empirical data from a surrogate population and concludes that orthosis design is more influential than the duration of wear.


Assuntos
Braquetes/efeitos adversos , Dor/etiologia , Adulto , Fatores Etários , Desenho de Equipamento , Estética , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço , Pressão/efeitos adversos , Fatores de Tempo , Adulto Jovem
2.
Clin Biomech (Bristol, Avon) ; 32: 201-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26673978

RESUMO

BACKGROUND: This study aimed at quantifying the biomechanical features of the Sheffield Support Snood, a cervical orthosis specifically designed for patients with neck muscle weakness. The orthosis is designed to be adaptable to a patient's level of functional limitation using adjustable removable supports, which contribute support and restrict movement only in desired anatomical planes. METHODS: The snood was evaluated along with two commercially available orthoses, the Vista and Headmaster, in a series of flexion, extension, axial-rotation and lateral flexion movements. Characterization was performed with twelve healthy participants with and without the orthoses. Two inertial-magneto sensors, placed on the forehead and sternum, were used to quantify the neck's range of motion. FINDINGS: In its less supportive configuration, the snood was effective in limiting movements to the desired planes, preserving free movement in other planes. The Headmaster was only effective in limiting flexion. The range of motion achieved with the snood in its rigid configuration was equivalent (P>0.05, effect size<0.4) to that achieved with the Vista, both in trials performed reaching the maximum amplitude (range of motion reduction: 25%-34% vs 24%-47%) and at maximum speed (range of motion reduction: 24%-29% vs 25%-43%). INTERPRETATION: The Sheffield Support Snood is effectively adaptable to different tasks and, in its most supportive configuration, offers a support comparable to the Vista, but providing a less bulky structure. The chosen method is suitable for the assessment of range of motions while wearing neck orthoses and is easily translatable in a clinical context.


Assuntos
Braquetes , Vértebras Cervicais/fisiopatologia , Debilidade Muscular/fisiopatologia , Pescoço/fisiopatologia , Aparelhos Ortopédicos , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Movimento/fisiologia , Equipamentos Ortopédicos , Amplitude de Movimento Articular/fisiologia , Rotação , Adulto Jovem
3.
J Med Eng Technol ; 39(7): 382-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26415684

RESUMO

This paper describes and discusses the role of unmet needs in the innovation of new medical technologies using the National Institute for Health Research Devices for Dignity (D4D) Healthcare Technology Co-operative as a case study. It defines an unmet need, providing a spectrum of classification and discusses the benefits and the challenges of identifying unmet need and its influence on the innovation process. The process by which D4D has captured and utilized unmet needs to drive technology innovation is discussed and examples given. It concludes by arguing that, despite the challenges, defining and reviewing unmet need is a fundamental factor in the success of medical technology innovation.


Assuntos
Tecnologia Biomédica/instrumentação , Equipamentos e Provisões , Invenções , Avaliação das Necessidades/organização & administração , Avaliação da Tecnologia Biomédica/métodos , Avaliação da Tecnologia Biomédica/organização & administração , Reino Unido
4.
J Med Eng Technol ; 39(7): 404-10, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26453038

RESUMO

This paper presents the Head-Up project, that aims to provide innovative head support to help improve posture, relieve pain and aid communication for people living with progressive neck muscle weakness. The initial focus is motor neurone disease. The case study illustrates collaborative, interdisciplinary research and new product development underpinned by participatory design. The study was initiated by a 2-day stakeholder workshop followed by early proof-of-concept modelling and patient need evidence building. The work subsequently led to a successful NIHR i4i application funding a 24-month iterative design process, patenting, CE marking and clinical evaluation. The evaluation has informed amendments to the proposed design refered to here as the Sheffield Support Snood (SSS). The outcome positively demonstrates use and performance improvements over current neck orthoses and the process of multidisciplinary and user engagement has created a sense of ownership by MND participants, who have since acted as advocates for the product.


Assuntos
Braquetes , Doença dos Neurônios Motores/reabilitação , Debilidade Muscular/reabilitação , Equipe de Assistência ao Paciente/organização & administração , Participação do Paciente/métodos , Desenho de Prótese/métodos , Tecnologia Biomédica/métodos , Tecnologia Biomédica/organização & administração , Humanos , Músculos do Pescoço , Avaliação das Necessidades/organização & administração , Assistência Centrada no Paciente/métodos , Assistência Centrada no Paciente/organização & administração , Avaliação da Tecnologia Biomédica/métodos , Avaliação da Tecnologia Biomédica/organização & administração , Reino Unido
5.
J Med Eng Technol ; 39(7): 434-40, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-26453040

RESUMO

Urinary incontinence, the leakage of urine, is a common condition, which can have a significant impact on a patient's quality-of-life. Incontinence may arise as a consequence of a weakness of the urinary sphincter or bladder dysfunction, usually over-activity. Incontinence therapies occupy a large proportion of the healthcare budget. As no single device to manage incontinence is appropriate for all situations, a diverse range of products are available on the market and the development of improved products based on fundamental designs has been slow. This review highlights some of the key issues of continence care and describes the current technology and recent developments involved in the diagnosis, assessment and treatment of incontinence, along with the strengths and limitations of these methods. These issues are imperative to address if improved technology is to be developed.


Assuntos
Técnicas de Diagnóstico Urológico/tendências , Terapia por Estimulação Elétrica/tendências , Testes de Função Renal/tendências , Urinálise/tendências , Incontinência Urinária/diagnóstico , Incontinência Urinária/terapia , Tecnologia Biomédica/tendências , Feminino , Humanos , Masculino , Slings Suburetrais/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA