Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Lancet Digit Health ; 1(7): e344-e352, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-33323209

RESUMO

BACKGROUND: Smartphone apps might enable interventions to increase physical activity, but few randomised trials testing this hypothesis have been done. The MyHeart Counts Cardiovascular Health Study is a longitudinal smartphone-based study with the aim of elucidating the determinants of cardiovascular health. We aimed to investigate the effect of four different physical activity coaching interventions on daily step count in a substudy of the MyHeart Counts Study. METHODS: In this randomised, controlled crossover trial, we recruited adults (aged ≥18 years) in the USA with access to an iPhone smartphone (Apple, Cupertino, CA, USA; version 5S or newer) who had downloaded the MyHeart Counts app (version 2.0). After completion of a 1 week baseline period of interaction with the MyHeart Counts app, participants were randomly assigned to receive one of 24 permutations (four combinations of four 7 day interventions) in a crossover design using a random number generator built into the app. Interventions consisted of either daily prompts to complete 10 000 steps, hourly prompts to stand following 1 h of sitting, instructions to read the guidelines from the American Heart Association website, or e-coaching based upon the individual's personal activity patterns from the baseline week of data collection. Participants completed the trial in a free-living setting. Due to the nature of the interventions, participants could not be masked from the intervention. Investigators were not masked to intervention allocation. The primary outcome was change in mean daily step count from baseline for each of the four interventions, assessed in the modified intention-to-treat analysis set, which included all participants who had completed 7 days of baseline monitoring and at least 1 day of one of the four interventions. This trial is registered with ClinicalTrials.gov, NCT03090321. FINDINGS: Between Dec 12, 2016, and June 6, 2018, 2783 participants consented to enrol in the coaching study, of whom 1075 completed 7 days of baseline monitoring and at least 1 day of one of the four interventions and thus were included in the modified intention-to-treat analysis set. 493 individuals completed the full set of assigned interventions. All four interventions significantly increased mean daily step count from baseline (mean daily step count 2914 [SE 74]): mean step count increased by 319 steps (75) for participants in the American Heart Association website prompt group (p<0·0001), 267 steps (74) for participants in the hourly stand prompt group (p=0·0003), 254 steps (74) for participants in the cluster-specific prompts group (p=0·0006), and by 226 steps (75) for participants in the 10 000 daily step prompt group (p=0·0026 vs baseline). INTERPRETATION: Four smartphone-based physical activity coaching interventions significantly increased daily physical activity. These findings suggests that digital interventions delivered via a mobile app have the ability to increase short-term physical activity levels in a free-living cohort. FUNDING: Stanford Data Science Initiative.


Assuntos
Doenças Cardiovasculares/prevenção & controle , Exercício Físico/fisiologia , Promoção da Saúde , Aplicativos Móveis/estatística & dados numéricos , Adulto , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Smartphone , Estados Unidos
2.
Circulation ; 137(18): e495-e522, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29618598

RESUMO

Physical inactivity is one of the most prevalent major health risk factors, with 8 in 10 US adults not meeting aerobic and muscle-strengthening guidelines, and is associated with a high burden of cardiovascular disease. Improving and maintaining recommended levels of physical activity leads to reductions in metabolic, hemodynamic, functional, body composition, and epigenetic risk factors for noncommunicable chronic diseases. Physical activity also has a significant role, in many cases comparable or superior to drug interventions, in the prevention and management of >40 conditions such as diabetes mellitus, cancer, cardiovascular disease, obesity, depression, Alzheimer disease, and arthritis. Whereas most of the modifiable cardiovascular disease risk factors included in the American Heart Association's My Life Check - Life's Simple 7 are evaluated routinely in clinical practice (glucose and lipid profiles, blood pressure, obesity, and smoking), physical activity is typically not assessed. The purpose of this statement is to provide a comprehensive review of the evidence on the feasibility, validity, and effectiveness of assessing and promoting physical activity in healthcare settings for adult patients. It also adds concrete recommendations for healthcare systems, clinical and community care providers, fitness professionals, the technology industry, and other stakeholders in order to catalyze increased adoption of physical activity assessment and promotion in healthcare settings and to contribute to meeting the American Heart Association's 2020 Impact Goals.


Assuntos
Doenças Cardiovasculares/prevenção & controle , Exercício Físico , Promoção da Saúde , Estilo de Vida Saudável , Comportamento de Redução do Risco , American Heart Association , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/fisiopatologia , Nível de Saúde , Humanos , Prognóstico , Fatores de Proteção , Fatores de Risco , Comportamento Sedentário , Estados Unidos/epidemiologia
3.
Prog Cardiovasc Dis ; 58(6): 584-94, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26923067

RESUMO

Physical activity (PA) interventions constitute a critical component of cardiovascular disease (CVD) risk reduction programs. Objective mobile health (mHealth) software applications (apps) and wearable activity monitors (WAMs) can advance both assessment and integration of PA counseling in clinical settings and support community-based PA interventions. The use of mHealth technology for CVD risk reduction is promising, but integration into routine clinical care and population health management has proven challenging. The increasing diversity of available technologies and the lack of a comprehensive guiding framework are key barriers for standardizing data collection and integration. This paper reviews the validity, utility and feasibility of implementing mHealth technology in clinical settings and proposes an organizational framework to support PA assessment, counseling and referrals to community resources for CVD risk reduction interventions. This integration framework can be adapted to different clinical population needs. It should also be refined as technologies and regulations advance under an evolving health care system landscape in the United States and globally.


Assuntos
Tecnologia Biomédica/tendências , Doenças Cardiovasculares/prevenção & controle , Aconselhamento/tendências , Prestação Integrada de Cuidados de Saúde/tendências , Exercício Físico , Estilo de Vida Saudável , Aplicativos Móveis/tendências , Telemedicina/tendências , Atitude Frente aos Computadores , Tecnologia Biomédica/instrumentação , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Segurança Computacional , Confidencialidade , Difusão de Inovações , Previsões , Comportamentos Relacionados com a Saúde , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Aceitação pelo Paciente de Cuidados de Saúde , Fatores de Proteção , Medição de Risco , Fatores de Risco , Comportamento de Redução do Risco , Comportamento Sedentário , Telemedicina/instrumentação , Fluxo de Trabalho
4.
Nat Commun ; 5: 5028, 2014 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-25284074

RESUMO

Continuous monitoring of internal physiological parameters is essential for critical care patients, but currently can only be practically achieved via tethered solutions. Here we report a wireless, real-time pressure monitoring system with passive, flexible, millimetre-scale sensors, scaled down to unprecedented dimensions of 1 × 1 × 0.1 cubic millimeters. This level of dimensional scaling is enabled by novel sensor design and detection schemes, which overcome the operating frequency limits of traditional strategies and exhibit insensitivity to lossy tissue environments. We demonstrate the use of this system to capture human pulse waveforms wirelessly in real time as well as to monitor in vivo intracranial pressure continuously in proof-of-concept mice studies using sensors down to 2.5 × 2.5 × 0.1 cubic millimeters. We further introduce printable wireless sensor arrays and show their use in real-time spatial pressure mapping. Looking forward, this technology has broader applications in continuous wireless monitoring of multiple physiological parameters for biomedical research and patient care.


Assuntos
Cuidados Críticos/métodos , Monitorização Fisiológica/métodos , Tecnologia sem Fio , Animais , Calibragem , Radiação Eletromagnética , Desenho de Equipamento , Humanos , Masculino , Teste de Materiais , Camundongos , Camundongos Endogâmicos C57BL , Pressão
5.
Circ Cardiovasc Imaging ; 7(4): 690-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24814820

RESUMO

BACKGROUND: Ascending aortic dissection and rupture remain a life-threatening complication in patients with Marfan syndrome. The extracellular matrix provides strength and elastic recoil to the aortic wall, thereby preventing radial expansion. We have previously shown that ascending aortic aneurysm formation in Marfan mice (Fbn1(C1039G/+)) is associated with decreased aortic wall elastogenesis and increased elastin breakdown. In this study, we test the feasibility of quantifying aortic wall elastin content using MRI with a gadolinium-based elastin-specific magnetic resonance contrast agent in Fbn1(C1039G/+) mice. METHODS AND RESULTS: Ascending aorta elastin content was measured in 32-week-old Fbn1(C1039G/+) mice and wild-type (n=9 and n=10, respectively) using 7-T MRI with a T1 mapping sequence. Significantly lower enhancement (ie, lower R1 values, where R1=1/T1) was detected post-elastin-specific magnetic resonance contrast agent in Fbn1(C1039G/+) compared with wild-type ascending aortas (1.15±0.07 versus 1.36±0.05; P<0.05). Post-elastin-specific magnetic resonance contrast agent R1 values correlated with ascending aortic wall gadolinium content directly measured by inductively coupled mass spectroscopy (P=0.006). CONCLUSIONS: Herein, we demonstrate that MRI with elastin-specific magnetic resonance contrast agent accurately measures elastin bound gadolinium within the aortic wall and detects a decrease in aortic wall elastin in Marfan mice compared with wild-type controls. This approach has translational potential for noninvasively assessing aneurysm tissue changes and risk, as well as monitoring elastin content in response to therapeutic interventions.


Assuntos
Aorta Torácica/química , Aneurisma da Aorta Torácica/diagnóstico , Dissecção Aórtica/diagnóstico , Meios de Contraste , Elastina/deficiência , Imageamento por Ressonância Magnética/métodos , Síndrome de Marfan/complicações , Dissecção Aórtica/etiologia , Dissecção Aórtica/metabolismo , Animais , Aorta Torácica/patologia , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/metabolismo , Quelantes , Modelos Animais de Doenças , Elastina/análise , Estudos de Viabilidade , Compostos Heterocíclicos com 1 Anel , Masculino , Síndrome de Marfan/diagnóstico , Síndrome de Marfan/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes
6.
Circ Cardiovasc Imaging ; 7(4): 655-62, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24777939

RESUMO

BACKGROUND: Biomarkers improve cardiovascular disease (CVD) risk prediction, but their comparative effectiveness in clinical practice is not known. We sought to compare the use, spending, and clinical outcomes in asymptomatic Medicare beneficiaries evaluated for CVD with coronary artery calcium (CAC) or other cardiovascular risk markers. METHODS AND RESULTS: We used a 20% sample of 2005 to 2011 Medicare claims to identify fee-for-service beneficiaries aged ≥65.5 years with no CVD claims in the previous 6 months. We matched patients with CAC with patients who received high-sensitivity C-reactive protein (hs-CRP; n=8358) or lipid screening (n=6250) using propensity-score methods. CAC was associated with increased noninvasive cardiac testing within 180 days (hazard ratio, 2.22, 95% confidence interval, 1.68-2.93, P<0.001, versus hs-CRP; hazard ratio, 4.30, 95% confidence interval, 3.04-6.06, P<0.001, versus lipid screening) and increased coronary angiography and revascularization. During 3-year follow-up, CAC was associated with higher CVD-related spending ($6525 versus $4432 for hs-CRP, P<0.001; and $6500 versus $3073 for lipid screening, P<0.001) and fewer CVD-related events when compared with hs-CRP (hazard ratio, 0.74, 95% confidence interval, 0.58-0.94, P=0.017) but not compared with lipid screening (hazard ratio, 0.84, 95% confidence interval, 0.64-1.11, P=0.23). CONCLUSIONS: CAC testing among asymptomatic Medicare beneficiaries was associated with increased use of cardiac tests and procedures, higher spending, and slightly improved clinical outcomes when compared with hs-CRP testing.


Assuntos
Biomarcadores/análise , Calcinose/metabolismo , Cálcio/análise , Doença da Artéria Coronariana/metabolismo , Vasos Coronários/química , Planos de Pagamento por Serviço Prestado/economia , Medicare/economia , Idoso , Proteína C-Reativa/análise , Calcinose/diagnóstico , Calcinose/economia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/economia , Feminino , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Estados Unidos
7.
J Biomed Biotechnol ; 2011: 252141, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21331328

RESUMO

AIMS: The aim of this study was to definitively assess the validity of noninvasive high-frequency ultrasound (US) measurements of aortic luminal diameter (ALD) in a murine model of elastase-induced abdominal aortic aneurysm in comparison with in situ video microscopy (VM). METHODS: C57BL/6 mice underwent transient perfusion of the aorta with either elastase (n = 20: Elastase group) or saline (n = 10: Sham). Unoperated mice (n = 10) were also studied. RESULTS: ALD measurements by US had excellent linear correlation and absolute agreement with that by VM in both Control (unoperated or sham-operated mice) and elastase groups (r = 0.96, intraclass correlation coefficient (ICC) = 0.88 and r = 0.93, ICC = 0.92, resp.). Bland-Altman analysis of US compared with VM measurements in both groups indicated good agreement, however US measurements were slightly but significantly higher than VM measurements in the control group (mean bias 0.039 mm, P < .05). Linear regression analysis revealed excellent correlation between US and VM measurements in both groups. (R² = 0.91 in Control group, R² = 0.85 in elastase group.) The reliability of US measurements was also confirmed by ex vivo histological measurements. CONCLUSIONS: High-frequency US provides reliable ALD measurements in developing murine abdominal aortic aneurysms.


Assuntos
Aneurisma da Aorta Abdominal/induzido quimicamente , Aneurisma da Aorta Abdominal/patologia , Microscopia de Vídeo/métodos , Ultrassonografia/métodos , Animais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Modelos Animais de Doenças , Imuno-Histoquímica , Modelos Lineares , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Elastase Pancreática , Reprodutibilidade dos Testes
8.
J Cardiovasc Magn Reson ; 10: 28, 2008 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-18513419

RESUMO

BACKGROUND: Impaired coronary vasodilation to both endothelial-dependent and endothelial-independent stimuli have been associated with atherosclerosis. Direct measurement of coronary vasodilation using x-ray angiography or intravascular ultrasound is invasive and, thus, not appropriate for asymptomatic patients or for serial follow-up. In this study, high-resolution coronary cardiovascular magnetic resonance (CMR) was used to investigate the vasodilatory response to nitroglycerine (NTG) of asymptomatic patients at high risk for CAD. METHODS: A total of 46 asymptomatic subjects were studied: 13 high-risk patients [8 with diabetes mellitus (DM), 5 with end stage renal disease (ESRD)] and 33 age-matched controls. Long-axis and cross-sectional coronary artery images were acquired pre- and 5 minutes post-sublingual NTG using a sub-mm-resolution multi-slice spiral coronary CMR sequence. Coronary cross sectional area (CSA) was measured on pre- and post-NTG images and % coronary vasodilation was calculated. RESULTS: Patients with DM and ESRD had impaired coronary vasodilation to NTG compared to age-matched controls (17.8 +/- 7.3% vs. 25.6 +/- 7.1%, p = 0.002). This remained significant for ESRD patients alone (14.8 +/- 7.7% vs. 25.6 +/- 7.1%; p = 0.003) and for DM patients alone (19.8 +/- 6.3% vs. 25.6 +/- 7.1%; p = 0.049), with a non-significant trend toward greater impairment in the ESRD vs. DM patients (14.8 +/- 7.7% vs. 19.8 +/- 6.3%; p = 0.23). CONCLUSION: Noninvasive coronary CMR demonstrates impairment of coronary vasodilation to NTG in high-risk patients with DM and ESRD. This may provide a functional indicator of subclinical atherosclerosis and warrants clinical follow up to determine prognostic significance.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Vasodilatação , Pressão Sanguínea/efeitos dos fármacos , Doença da Artéria Coronariana/complicações , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/patologia , Diabetes Mellitus/fisiopatologia , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Processamento de Imagem Assistida por Computador , Falência Renal Crônica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Nitroglicerina , Fatores de Risco , Fatores Sexuais , Vasodilatação/efeitos dos fármacos , Vasodilatadores
9.
J Am Coll Cardiol ; 45(1): 104-10, 2005 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-15629383

RESUMO

OBJECTIVES: The purpose of this study was to investigate the use of coronary magnetic resonance angiography (MRA) for assessing human epicardial coronary artery vasodilation. BACKGROUND: Coronary vasodilation plays a vital role in the human coronary circulation. Previous studies of epicardial coronary vasodilation have used invasive coronary angiography. Coronary MRA may provide an alternative noninvasive method to directly assess changes in coronary size. METHODS: Thirty-two subjects were studied: 12 patients (age 55 +/- 18 years) and 20 healthy subjects (age 34 +/- 4 years). High-resolution multi-slice spiral coronary MRA (in-plane resolution of 0.52 to 0.75 mm) was performed before and after sublingual nitroglycerin (NTG). Quantitative analysis of coronary vasodilation was performed on cross-sectional images of the right coronary artery (RCA). A time-course analysis of coronary vasodilation was performed in a subset of eight subjects for 30 min after NTG. Signal-to-noise ratio was also measured on the in-plane RCA images. RESULTS: Coronary MRA demonstrated a 23% increase in cross-sectional area after NTG (16.9 +/- 7.8 mm2 to 20.8 +/- 8.9 mm2, p <0.0001), with significant vasodilation between 3 and 15 min after NTG on time-course analysis. The MRA measurements had low interobserver variability (< or =5%) and good correlation with X-ray angiography (r=0.98). The magnitude of vasodilation correlated with baseline cross-sectional area (r=0.52, p=0.03) and age (r=0.40, p=0.019). Post-NTG images also demonstrated a 31% improvement in coronary signal-to-noise ratio (p = 0.002). CONCLUSIONS: Nitroglycerin-enhanced coronary MRA can noninvasively measure coronary artery vasodilation and is a promising noninvasive technique to study coronary vasomotor function.


Assuntos
Vasos Coronários/fisiologia , Angiografia por Ressonância Magnética , Vasodilatação , Adulto , Circulação Coronária/fisiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Nitroglicerina , Vasodilatadores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA