Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Magn Reson Med ; 89(1): 343-355, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36089805

RESUMO

PURPOSE: To assess the potential of DCE MR CEST urography for assessing renal function in mice with unilateral ureter obstruction (UUO) by simultaneous pH and renal uptake/clearance measurements following injection of iopamidol. METHODS: The right ureter of nine mice was obstructed via suture ligation. The animals were imaged at day 1, 2, and 3 post-obstruction on an 11.7T MRI scanner. Ninety-six sets of saturated CEST images at 4.3 and 5.5 ppm were collected. Renal pH values were obtained by calculating the signal ratio for these two frequencies and using a pH calibration curve. Renal time activity curves were measured as a percentage change in the post-injection CEST signal at 4.3 ppm relative to the average pre-injection signal. RESULTS: For the healthy mice, the time activity curves of both kidneys were nearly identical and displayed rapid excretion of contrast. For the UUO mice, the dynamic CEST curves for the obstructed kidneys displayed prolonged time to peak (TTP) values and delayed contrast excretion compared with the contralateral (CL) kidneys. Renal pH maps of the healthy animals showed similar acidic values for both kidneys (pH 6.65 ± 0.04 vs 6.67 ± 0.02), whereas in the obstructed kidneys there was a significant increase in pH values compared with the CL kidneys (pH 6.67 ± 0.08 vs 6.79 ± 0.11 in CL and UUO kidneys, respectively). CONCLUSION: Our findings indicate that DCE-MR-CEST urography can detect changes in renal uptake/excretion and pH homeostasis and distinguish between obstructed and unobstructed kidney as early as 1 day after UUO.


Assuntos
Ureter , Obstrução Ureteral , Animais , Camundongos , Obstrução Ureteral/diagnóstico por imagem , Rim/diagnóstico por imagem , Rim/fisiologia , Imageamento por Ressonância Magnética/métodos , Concentração de Íons de Hidrogênio , Urografia
2.
Magn Reson Med ; 80(6): 2449-2463, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29756286

RESUMO

PURPOSE: To develop a fast magnetic resonance fingerprinting (MRF) method for quantitative chemical exchange saturation transfer (CEST) imaging. METHODS: We implemented a CEST-MRF method to quantify the chemical exchange rate and volume fraction of the Nα -amine protons of L-arginine (L-Arg) phantoms and the amide and semi-solid exchangeable protons of in vivo rat brain tissue. L-Arg phantoms were made with different concentrations (25-100 mM) and pH (pH 4-6). The MRF acquisition schedule varied the saturation power randomly for 30 iterations (phantom: 0-6 µT; in vivo: 0-4 µT) with a total acquisition time of ≤2 min. The signal trajectories were pattern-matched to a large dictionary of signal trajectories simulated using the Bloch-McConnell equations for different combinations of exchange rate, exchangeable proton volume fraction, and water T1 and T2 relaxation times. RESULTS: The chemical exchange rates of the Nα -amine protons of L-Arg were significantly (P < 0.0001) correlated with the rates measured with the quantitation of exchange using saturation power method. Similarly, the L-Arg concentrations determined using MRF were significantly (P < 0.0001) correlated with the known concentrations. The pH dependence of the exchange rate was well fit (R2 = 0.9186) by a base catalyzed exchange model. The amide proton exchange rate measured in rat brain cortex (34.8 ± 11.7 Hz) was in good agreement with that measured previously with the water exchange spectroscopy method (28.6 ± 7.4 Hz). The semi-solid proton volume fraction was elevated in white (12.2 ± 1.7%) compared to gray (8.1 ± 1.1%) matter brain regions in agreement with previous magnetization transfer studies. CONCLUSION: CEST-MRF provides a method for fast, quantitative CEST imaging.


Assuntos
Substância Cinzenta/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Substância Branca/diagnóstico por imagem , Algoritmos , Aminas/química , Animais , Arginina/química , Encéfalo/diagnóstico por imagem , Concentração de Íons de Hidrogênio , Aumento da Imagem/métodos , Masculino , Método de Monte Carlo , Imagens de Fantasmas , Prótons , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
J Cereb Blood Flow Metab ; 36(7): 1186-94, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26980755

RESUMO

The blood-brain barrier (BBB) is a major obstacle for drug delivery to the brain. Predicted, focal opening of the BBB through intra-arterial infusion of hyperosmolar mannitol is feasible, but there is a need to facilitate imaging techniques (e.g. MRI) to guide interventional procedures and assess the outcomes. Here, we show that salicylic acid analogues (SAA) can depict the brain territory supplied by the catheter and detect the BBB opening, through chemical exchange saturation transfer (CEST) MRI. Hyperosmolar SAA solutions themselves are also capable of opening the BBB, and, when multiple SAA agents were co-injected, their locoregional perfusion could be differentiated.


Assuntos
Barreira Hematoencefálica/diagnóstico por imagem , Meios de Contraste/química , Imagem por Ressonância Magnética Intervencionista/métodos , Imagem de Perfusão/métodos , Ácido Salicílico/química , Animais , Barreira Hematoencefálica/metabolismo , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Hidroxibenzoatos/administração & dosagem , Hidroxibenzoatos/química , Infusões Intra-Arteriais , Concentração Osmolar , Perfusão , Ácidos Ftálicos/administração & dosagem , Ácidos Ftálicos/química , Ratos Sprague-Dawley , Ácido Salicílico/administração & dosagem , Salicilato de Sódio/administração & dosagem , Salicilato de Sódio/química , Soluções
4.
Biomaterials ; 35(27): 7811-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24930848

RESUMO

By means of physical isolation of cells inside semi-permeable hydrogels, encapsulation has been widely used to immunoprotect transplanted cells. While spherical alginate microcapsules are now being used clinically, there still is little known about the patient's immune system response unless biopsies are obtained. We investigated the use of Magnetization Transfer (MT) imaging to non-invasively detect host immune responses against alginate capsules containing xenografted human hepatocytes in four groups of animals, including transplanted empty capsules (-Cells/-IS), capsules with live cells with (+LiveCells/+IS) and without immunosuppression (+LiveCells/-IS), and capsules with apoptotic cells in non-immunosuppressed animals (+DeadCells/-IS). The highest MT ratio (MTR) was found in +LiveCells/-IS, which increased from day 0 by 38% and 53% on days 7 and 14 after transplantation respectively, and corresponded to a distinctive increase in cell infiltration on histology. Furthermore, we show that macromolecular ratio maps based on MT data are more sensitive to cell infiltration and fibrosis than conventional MTR maps. Such maps showed a significant difference between +LiveCells/-IS (0.18 ± 0.02) and +DeadCells/-IS (0.13 ± 0.02) on day 7 (P < 0.01) existed, which was not observed on MTR imaging. We conclude that MT imaging, which is clinically available, can be applied for non-invasive monitoring of the occurrence of a host immune response against encapsulated cells.


Assuntos
Imunidade Adaptativa/efeitos dos fármacos , Alginatos/farmacologia , Hepatócitos/citologia , Hepatócitos/imunologia , Imunidade Inata/efeitos dos fármacos , Imageamento por Ressonância Magnética , Animais , Morte Celular/efeitos dos fármacos , Células Imobilizadas/citologia , Células Imobilizadas/efeitos dos fármacos , Ácido Glucurônico/farmacologia , Células Hep G2 , Hepatócitos/efeitos dos fármacos , Hepatócitos/transplante , Ácidos Hexurônicos/farmacologia , Humanos , Substâncias Macromoleculares/metabolismo , Masculino , Camundongos Endogâmicos BALB C , Coloração e Rotulagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA