Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Med Phys ; 44(9): e297-e338, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28644913

RESUMO

Since the publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG-43U1) and its 2007 supplement (TG-43U1S1), several new low-energy photon-emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical purposes and are posted on the Brachytherapy Source Registry managed jointly by the AAPM and the Imaging and Radiation Oncology Core Houston Quality Assurance Center (IROC Houston). Given increasingly closer interactions among physicists in North America and Europe, the AAPM and the Groupe Européen de Curiethérapie-European Society for Radiotherapy & Oncology (GEC-ESTRO) have prepared another supplement containing recommended brachytherapy dosimetry parameters for eleven low-energy photon-emitting brachytherapy sources. The current report presents consensus datasets approved by the AAPM and GEC-ESTRO. The following sources are included: 125 I sources (BEBIG model I25.S17, BEBIG model I25.S17plus, BEBIG model I25.S18, Elekta model 130.002, Oncura model 9011, and Theragenics model AgX100); 103 Pd sources (CivaTech Oncology model CS10, IBt model 1031L, IBt model 1032P, and IsoAid model IAPd-103A); and 131 Cs (IsoRay Medical model CS-1 Rev2). Observations are included on the behavior of these dosimetry parameters as a function of radionuclide. Recommendations are presented on the selection of dosimetry parameters, such as from societal reports issuing consensus datasets (e.g., TG-43U1, AAPM Report #229), the joint AAPM/IROC Houston Registry, the GEC-ESTRO website, the Carleton University website, and those included in software releases from vendors of treatment planning systems. Aspects such as timeliness, maintenance, and rigor of these resources are discussed. Links to reference data are provided for radionuclides (radiation spectra and half-lives) and dose scoring materials (compositions and mass densities). The recent literature is examined on photon energy response corrections for thermoluminescent dosimetry of low-energy photon-emitting brachytherapy sources. Depending upon the dosimetry parameters currently used by individual physicists, use of these recommended consensus datasets may result in changes to patient dose calculations. These changes must be carefully evaluated and reviewed with the radiation oncologist prior to their implementation.


Assuntos
Braquiterapia , Dosagem Radioterapêutica , Europa (Continente) , Humanos , Método de Monte Carlo , Fótons , Radiometria , Relatório de Pesquisa
2.
J Appl Clin Med Phys ; 15(2): 4620, 2014 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-24710449

RESUMO

The first quality assurance process for validating dose-volume histogram data involving brachytherapy procedures in radiation therapy is presented. The process is demonstrated using both low dose-rate and high dose-rate radionuclide sources. A rectangular cuboid was contoured in five commercially available brachytherapy treatment planning systems. A single radioactive source commissioned for QA testing was positioned coplanar and concentric with one end. Using the brachytherapy dosimetry formalism defined in the AAPM Task Group 43 report series, calculations were performed to estimate dose deposition in partial volumes of the cuboid structure. The point-source approximation was used for a 125I source and the line-source approximation was used for a 192Ir source in simulated permanent and temporary implants, respectively. Hand-calculated, dose-volume results were compared to TPS-generated, dose-volume histogram (DVH) data to ascertain acceptance. The average disagreement observed between hand calculations and the treatment planning system DVH was less than 1% for the five treatment planning systems and less than 5% for 1 cm ≤ r ≤ 5 cm. A reproducible method for verifying the accuracy of volumetric statistics from a radiation therapy TPS can be employed. The process satisfies QA requirements for TPS commissioning, upgrading, and annual testing. We suggest that investigations be performed if the DVH %Vol(TPS) "actual variance" calculations differ by more than 5% at any specific radial distance with respect to %Vol(TG-43), or if the "average variance" DVH %Vol(TPS) calculations differ by more than 2% over all radial distances with respect to %Vol(TG-43).


Assuntos
Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Radioisótopos do Iodo/química , Radioisótopos de Irídio/química , Modelos Estatísticos , Método de Monte Carlo , Controle de Qualidade , Radioisótopos/uso terapêutico , Radiometria/métodos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
3.
Brachytherapy ; 13(3): 304-10, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24139289

RESUMO

PURPOSE: The aim of this study was to analyze the dosimetric influence of conventional spacers and a cobalt chloride complex contrast (C4) agent, a novel marker for MRI that can also serve as a seed spacer, adjacent to (103)Pd, (125)I, and (131)Cs sources for permanent prostate brachytherapy. METHODS AND MATERIALS: Monte Carlo methods for radiation transport were used to estimate the dosimetric influence of brachytherapy end-weld thicknesses and spacers near the three sources. Single-source assessments and volumetric conditions simulating prior patient treatments were computed. Volume-dose distributions were imported to a treatment planning system for dose-volume histogram analyses. RESULTS: Single-source assessment revealed that brachytherapy spacers primarily attenuated the dose distribution along the source long axis. The magnitude of the attenuation at 1 cm on the long axis ranged from -10% to -5% for conventional spacers and approximately -2% for C4 spacers, with the largest attenuation for (103)Pd. Spacer perturbation of dose distributions was less than manufacturing tolerances for brachytherapy sources as gleaned by an analysis of end-weld thicknesses. Volumetric Monte Carlo assessment demonstrated that TG-43 techniques overestimated calculated doses by approximately 2%. Specific dose-volume histogram metrics for prostate implants were not perturbed by inclusion of conventional or C4 spacers in clinical models. CONCLUSIONS: Dosimetric perturbations of single-seed dose distributions by brachytherapy spacers exceeded 10% along the source long axes adjacent to the spacers. However, no dosimetric impact on volumetric parameters was noted for brachytherapy spacers adjacent to (103)Pd, (125)I, or (131)Cs sources in the context of permanent prostate brachytherapy implants.


Assuntos
Braquiterapia/métodos , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Humanos , Masculino , Modelos Teóricos , Método de Monte Carlo , Radiometria/métodos
4.
Med Phys ; 39(10): 6161-84, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23039655

RESUMO

Dosimetry of eye plaques for ocular tumors presents unique challenges in brachytherapy. The challenges in accurate dosimetry are in part related to the steep dose gradient in the tumor and critical structures that are within millimeters of radioactive sources. In most clinical applications, calculations of dose distributions around eye plaques assume a homogenous water medium and full scatter conditions. Recent Monte Carlo (MC)-based eye-plaque dosimetry simulations have demonstrated that the perturbation effects of heterogeneous materials in eye plaques, including the gold-alloy backing and Silastic insert, can be calculated with reasonable accuracy. Even additional levels of complexity introduced through the use of gold foil "seed-guides" and custom-designed plaques can be calculated accurately using modern MC techniques. Simulations accounting for the aforementioned complexities indicate dose discrepancies exceeding a factor of ten to selected critical structures compared to conventional dose calculations. Task Group 129 was formed to review the literature; re-examine the current dosimetry calculation formalism; and make recommendations for eye-plaque dosimetry, including evaluation of brachytherapy source dosimetry parameters and heterogeneity correction factors. A literature review identified modern assessments of dose calculations for Collaborative Ocular Melanoma Study (COMS) design plaques, including MC analyses and an intercomparison of treatment planning systems (TPS) detailing differences between homogeneous and heterogeneous plaque calculations using the American Association of Physicists in Medicine (AAPM) TG-43U1 brachytherapy dosimetry formalism and MC techniques. This review identified that a commonly used prescription dose of 85 Gy at 5 mm depth in homogeneous medium delivers about 75 Gy and 69 Gy at the same 5 mm depth for specific (125)I and (103)Pd sources, respectively, when accounting for COMS plaque heterogeneities. Thus, the adoption of heterogeneous dose calculation methods in clinical practice would result in dose differences >10% and warrant a careful evaluation of the corresponding changes in prescription doses. Doses to normal ocular structures vary with choice of radionuclide, plaque location, and prescription depth, such that further dosimetric evaluations of the adoption of MC-based dosimetry methods are needed. The AAPM and American Brachytherapy Society (ABS) recommend that clinical medical physicists should make concurrent estimates of heterogeneity-corrected delivered dose using the information in this report's tables to prepare for brachytherapy TPS that can account for material heterogeneities and for a transition to heterogeneity-corrected prescriptive goals. It is recommended that brachytherapy TPS vendors include material heterogeneity corrections in their systems and take steps to integrate planned plaque localization and image guidance. In the interim, before the availability of commercial MC-based brachytherapy TPS, it is recommended that clinical medical physicists use the line-source approximation in homogeneous water medium and the 2D AAPM TG-43U1 dosimetry formalism and brachytherapy source dosimetry parameter datasets for treatment planning calculations. Furthermore, this report includes quality management program recommendations for eye-plaque brachytherapy.


Assuntos
Comportamento Cooperativo , Neoplasias Oculares/radioterapia , Olho/efeitos da radiação , Melanoma/radioterapia , Paládio/uso terapêutico , Relatório de Pesquisa , Sociedades Médicas , Braquiterapia , Olho/patologia , Neoplasias Oculares/patologia , Neoplasias Oculares/cirurgia , Humanos , Radioisótopos do Iodo/uso terapêutico , Melanoma/patologia , Melanoma/cirurgia , Método de Monte Carlo , Período Pós-Operatório , Período Pré-Operatório , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem
5.
Med Phys ; 38(3): 1519-25, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21520863

RESUMO

PURPOSE: AccuBoost is a noninvasive image-guided technique for the delivery of partial breast irradiation to the tumor bed and currently serves as an alternate to conventional electron beam boost. To irradiate the target volume while providing dose sparing to the skin, the round applicator design was augmented through the addition of an internally truncated conical shield and the reduction of the source to skin distance. METHODS: Brachytherapy dose distributions for two types of conical applicators were simulated and estimated using Monte Carlo (MC) methods for radiation transport and a conventional treatment planning system (TPS). MC-derived and TPS-generated dose volume histograms (DVHs) and dose distribution data were compared for both the conical and round applicators for benchmarking purposes. RESULTS: Agreement using the gamma-index test was > or = 99.95% for distance to agreement and dose accuracy criteria of 2 mm and 2%, respectively. After observing good agreement, TPS DVHs and dose distributions for the conical and round applicators were obtained and compared. Brachytherapy dose distributions generated using Pinnacle for ten CT data sets showed that the parallel-opposed beams of the conical applicators provided similar PTV coverage to the round applicators and reduced the maximum dose to skin, chest wall, and lung by up to 27%, 42%, and 43%, respectively. CONCLUSIONS: Brachytherapy dose distributions for the conical applicators have been generated using MC methods and entered into the Pinnacle TPS via the Tufts technique. Treatment planning metrics for the conical AccuBoost applicators were significantly improved in comparison to those for conventional electron beam breast boost.


Assuntos
Braquiterapia/instrumentação , Neoplasias da Mama/radioterapia , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Pele/efeitos da radiação , Software , Benchmarking , Método de Monte Carlo , Dosagem Radioterapêutica
6.
Med Phys ; 38(1): 306-16, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21361199

RESUMO

PURPOSE: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using 125I or 103Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). METHODS: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose/EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. RESULTS: For the homogeneous water medium case, agreement was within approximately 2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific 125I and 103Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off-axis points-of-interest, dose differences approached factors of 7 and 12 at some positions for 125I and 103Pd, respectively. There was good agreement (approximately 3%) among MC codes and Plaque Simulator results when appropriate parameters calculated using MC codes were input into Plaque Simulator. Plaque Simulator and MC users are perhaps at risk of overdosing patients up to 20% if heterogeneity corrections are used and the prescribed dose is not modified appropriately. CONCLUSIONS: Agreement within 2% was observed among conventional brachytherapy TPS and MC codes for intraocular brachytherapy dose calculations in a homogeneous water environment. In general, the magnitude of dose errors incurred by ignoring the effect of the plaque backing and Silastic insert (i.e., by using the TG-43 approach) increased with distance from the plaque's central-axis. Considering the presence of material heterogeneities in a typical eye plaque, the best method in this study for dose calculations is a verified MC simulation.


Assuntos
Braquiterapia/métodos , Neoplasias Oculares/radioterapia , Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Radiometria
7.
Med Phys ; 36(11): 5027-32, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19994513

RESUMO

PURPOSE: The AccuBoost brachytherapy system applies HDR 192Ir beams peripherally to the breast using collimating applicators. The purpose of this study was to benchmark Monte Carlo simulations of the HDR 192Ir source, to dosimetrically characterize the round applicators using established Monte Carlo simulation and radiation measurement techniques and to gather data for clinical use. METHODS: Dosimetric measurements were performed in a polystyrene phantom, while simulations estimated dose in air, liquid water, polystyrene and ICRU 44 breast tissue. Dose distribution characterization of the 4-8 cm diameter collimators was performed using radiochromic EBT film and air ionization chambers. RESULTS: The central axis dose falloff was steeper for the 4 cm diameter applicator in comparison to the 8 cm diameter applicator, with surface to 3 cm depth-dose ratios of 3.65 and 2.44, respectively. These ratios did not considerably change when varying the phantom composition from breast tissue to polystyrene, phantom thickness from 4 to 8 cm, or phantom radius from 8 to 15 cm. Dose distributions on the central axis were fitted to sixth-order polynomials for clinical use in a hand calculation spreadsheet (i.e., nomogram). Dose uniformity within the useful applicator apertures decreased as depth-dose increased. CONCLUSIONS: Monte Carlo benchmarking simulations of the HDR 192Ir source using the MCNP5 radiation transport code indicated agreement within 1% of the published results over the radial/angular region of interest. Changes in phantom size and radius did not cause noteworthy changes in the central axis depth-dose. Polynomial fit depth-dose curves provide a simple and accurate basis for a nomogram.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Radioisótopos de Irídio/uso terapêutico , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Ar , Simulação por Computador , Feminino , Dosimetria Fotográfica , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Poliestirenos , Dosagem Radioterapêutica , Água
8.
Med Phys ; 36(9): 4250-6, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19810499

RESUMO

PURPOSE: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides (60Co, 137CS, 192Ir, and 169Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. METHODS: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source beta-, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the 192Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. RESULTS: Electronic equilibrium within 1% is reached for 60Co, 137CS, 192Ir, and 169Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for 60Co and 192Ir, respectively. Electron emissions become important (i.e., > 0.5%) within 3.3 mm of 60Co and 1.7 mm of 192Ir sources, yet are negligible over all distances for 137Cs and 169Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. CONCLUSIONS: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.


Assuntos
Braquiterapia , Elétrons/uso terapêutico , Radiometria/métodos , Dosagem Radioterapêutica , Braquiterapia/instrumentação , Radioisótopos de Césio , Radioisótopos de Cobalto , Simulação por Computador , Radioisótopos de Irídio , Modelos Teóricos , Método de Monte Carlo , Fótons , Doses de Radiação , Radioisótopos , Software , Água/química , Raios X , Itérbio
9.
Med Phys ; 36(6): 1968-75, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19610285

RESUMO

Certain brachytherapy dose distributions, such as those for LDR prostate implants, are readily modeled by treatment planning systems (TPS) that use the superposition principle of individual seed dose distributions to calculate the total dose distribution. However, dose distributions for brachytherapy treatments using high-Z shields or having significant material heterogeneities are not currently well modeled using conventional TPS. The purpose of this study is to establish a new treatment planning technique (Tufts technique) that could be applied in some clinical situations where the conventional approach is not acceptable and dose distributions present cylindrical symmetry. Dose distributions from complex brachytherapy source configurations determined with Monte Carlo methods were used as input data. These source distributions included the 2 and 3 cm diameter Valencia skin applicators from Nucletron, 4-8 cm diameter AccuBoost peripheral breast brachytherapy applicators from Advanced Radiation Therapy, and a 16 mm COMS-based eye plaque using 103Pd, 125I, and 131Cs seeds. Radial dose functions and 2D anisotropy functions were obtained by positioning the coordinate system origin along the dose distribution cylindrical axis of symmetry. Origin:tissue distance and active length were chosen to minimize TPS interpolation errors. Dosimetry parameters were entered into the PINNACLE TPS, and dose distributions were subsequently calculated and compared to the original Monte Carlo-derived dose distributions. The new planning technique was able to reproduce brachytherapy dose distributions for all three applicator types, producing dosimetric agreement typically within 2% when compared with Monte Carlo-derived dose distributions. Agreement between Monte Carlo-derived and planned dose distributions improved as the spatial resolution of the fitted dosimetry parameters improved. For agreement within 5% throughout the clinical volume, spatial resolution of dosimetry parameter data < or = 0.1 cm was required, and the virtual brachytherapy source data set included over 5000 data points. On the other hand, the lack of consideration for applicator heterogeneity effect caused conventional dose overestimates exceeding an order of magnitude in regions of clinical interest. This approach is rationalized by the improved dose estimates. In conclusion, a new technique was developed to incorporate complex Monte Carlo-based brachytherapy dose distributions into conventional TPS. These results are generalizable to other brachytherapy source types and other TPS.


Assuntos
Algoritmos , Braquiterapia/métodos , Modelos Biológicos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Software , Simulação por Computador , Humanos , Método de Monte Carlo , Dosagem Radioterapêutica , Espalhamento de Radiação
10.
Brachytherapy ; 7(4): 327-35, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18782684

RESUMO

PURPOSE: Modern dosimetry data are not available for Collaborative Ocular Melanoma Study-based eye plaques. This report aims to provide these data for eye plaques ranging from 10 to 22 mm, and for three different low-energy, photon-emitting radionuclides. METHODS AND MATERIALS: Recent publications on brachytherapy dosimetry parameters for 103Pd, 125I, and 131Cs were evaluated for use as eye plaque reference data. These data were entered into the Pinnacle treatment planning system for 3D calculations of brachytherapy dose distributions along the central axis for depths ranging from -1 to 10 mm based on the origin positioned at the inner sclera. In accordance with the original Collaborative Ocular Melanoma Study protocol and in the absence of radionuclide-specific heterogeneity factors, inhomogeneity corrections were not applied. RESULTS: As expected due to the mean photon energies, 103Pd, 125I, and 131Cs provided increasingly penetrating dose distributions. Dose distribution tables were prepared for fully loaded plaques and for plaques with the central source(s) removed. Over the entire range of central axis depths, and for all plaque sizes and loadings, 131Cs produced minimal outer scleral doses. Similarly, 103Pd generally produced more favorable dose distributions than 125I for depths less than 4mm. CONCLUSIONS: A modern analysis of eye plaque dosimetry evaluated dose as a function of lesion height and applicator size, and showed dependence on radionuclide selection and implant duration. For a fixed dose at the prescription point, we observed higher scleral dose corresponded with lower photon energy for a variety of plaque sizes and lesion heights.


Assuntos
Braquiterapia/instrumentação , Melanoma/radioterapia , Radioisótopos/administração & dosagem , Esclera/efeitos da radiação , Neoplasias Uveais/radioterapia , Braquiterapia/métodos , Relação Dose-Resposta à Radiação , Humanos , Método de Monte Carlo
11.
Med Phys ; 33(6): 1729-37, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16872080

RESUMO

Underlying characteristics in brachytherapy dosimetry parameters for medical radionuclides 137Cs, 125I, 192Ir, 103Pd, and 169Yb were examined using Monte Carlo methods. Sources were modeled as unencapsulated point or line sources in liquid water to negate variations due to materials and construction. Importance of phantom size, mode of radiation transport physics--i.e., photon transport only or coupled photon:electron transport, phantom material, volume averaging, and Monte Carlo tally type were studied. For noninfinite media, g(r) was found to degrade as r approached R, the phantom radius. MCNP5 results were in agreement with those published using GEANT4. Brachytherapy dosimetry parameters calculated using coupled photon:electron radiation transport simulations did not differ significantly from those using photon transport only. Dose distributions from low-energy photon-emitting radionuclides 125I and 103Pd were sensitive to phantom material by upto a factor of 1.4 and 2.0, respectively, between tissue-equivalent materials and water at r =9 cm. In comparison, high-energy photons from 137Cs, 192Ir, and 169Yb demonstrated +/- 5% differences in dose distributions between water and tissue substitutes at r=20 cm. Similarly, volume-averaging effects were found to be more significant for low-energy radionuclides. When modeling line sources with L < or = 0.5 cm, the two-dimensional anisotropy function was largely within +/- 0.5% of unity for 137Cs, 125I, and 192Ir. However, an energy and geometry effect was noted for 103Pd and 169Yb, with Pd-103F(0.5,0 degrees)=l.05 and yb-169F(0.5,0 degrees)=0.98 for L=0.5 cm. Simulations of monoenergetic photons for L=0.5 cm produced energy-dependent variations in F(r, theta) having a maximum value at 10 keV, minimum at 50 keV, and approximately 1.0 for higher-energy photons up to 750 keV. Both the F6 cell heating and *F4 track-length estimators were employed to determine brachytherapy dosimetry parameters. F6 was found to be necessary for g(r), while both tallies provided equivalent results for F(r, theta).


Assuntos
Braquiterapia/métodos , Fótons , Radioisótopos , Braquiterapia/instrumentação , Radioisótopos de Césio , Humanos , Radioisótopos do Iodo , Radioisótopos de Irídio , Método de Monte Carlo , Paládio , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Itérbio
12.
Med Phys ; 31(9): 2466-70, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15487726
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA