Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cardiovasc Digit Health J ; 5(1): 8-14, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38390583

RESUMO

Background: The availability of portable and wearable electrocardiographic (ECG) devices has increased secondary to technological development. Single-lead ECG recordings have been shown to reliably detect and characterize cardiac rhythms such as atrial fibrillation. Acquisition of precordial electrodes for full 12-lead ECG reconstruction from bipolar recordings is complicated by the absence of a body ground/Wilson central terminal electrode. The extent of difference between standard precordial leads and those from a wearable bipolar ECG recorder has not been characterized. Objective: The purpose of this study was to characterize the precordial ECG lead set from sequential bipolar recordings from an ECG ring wearable device. Methods: In 70 patients who wore an ECG device on a right-hand finger, sequential precordial leads (CR1-CR6) were obtained along with chest electrodes (V1-V6). During acquisition of the modified precordial lead CR6, a full standardized 12-lead ECG capture was obtained. Signal quality was assessed using automated analysis software, and correlation values between the ring-derived ECG precordial leads and standard ECG leads were compared with regard to QRS duration, QT width, and RR interval. Results: High concordance in the morphologies of precordial ECG leads obtained in a standard fashion and those recorded through an ECG ring was observed. Morphologic alignment improved with increasing laterality of the precordial lead with chest to right arm ring recording (CR5, CR6) compared with anterior chest leads to right arm (CR1, CR2). Segmental measurements of QRS duration and QT segment were well aligned and of high correlation. Conclusion: Wearable ring-based ECG technology is capable of high-fidelity recordings of precordial leads for nonsimultaneous reconstruction of complete ECG sets. These recordings correlate highly with surface-obtained QRS and QT duration measurements and have significant implications for clinical applications. Uninterpretable tracings were primarily due to electrode noise from poor electrode contact.

4.
Ann Intern Med ; 149(11): 822-4, 2008 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-19047030

RESUMO

Tax incentives can provide a large financial impetus to change behavior. Current U.S. law establishes a substantial discontinuity in the amount of estate tax that many patients will have to pay in 2010: During this year only, the tax rate drops to zero. This article discusses concerns regarding the sharp change in tax rate and the incentives it creates for persons who are nearing the end of life and provides estimates of the number of people affected by this issue.


Assuntos
Morte , Isenção Fiscal/legislação & jurisprudência , Impostos/economia , Humanos , Doente Terminal , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA