Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 38(1): 89-100, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37863862

RESUMO

PURPOSE: This systematic review of randomized-controlled trials (RCTs) with meta-analyses aimed to compare the effects on intraoperative arterial oxygen tension to inspired oxygen fraction ratio (PaO2/FiO2), exerted by positive end-expiratory pressure (PEEP) individualized trough electrical impedance tomography (EIT) or esophageal pressure (Pes) assessment (intervention) vs. PEEP not tailored on EIT or Pes (control), in patients undergoing abdominal or pelvic surgery with an open or laparoscopic/robotic approach. METHODS: PUBMED®, EMBASE®, and Cochrane Controlled Clinical trials register were searched for observational studies and RCTs from inception to the end of August 2022. Inclusion criteria were: RCTs comparing PEEP titrated on EIT/Pes assessment vs. PEEP not individualized on EIT/Pes and reporting intraoperative PaO2/FiO2. Two authors independently extracted data from the enrolled investigations. Data are reported as mean difference and 95% confidence interval (CI). RESULTS: Six RCTs were included for a total of 240 patients undergoing general anesthesia for surgery, of whom 117 subjects in the intervention group and 123 subjects in the control group. The intraoperative mean PaO2/FiO2 was 69.6 (95%CI 32.-106.4 ) mmHg higher in the intervention group as compared with the control group with 81.4% between-study heterogeneity (p < 0.01). However, at meta-regression, the between-study heterogeneity diminished to 44.96% when data were moderated for body mass index (estimate 3.45, 95%CI 0.78-6.11, p = 0.011). CONCLUSIONS: In patients undergoing abdominal or pelvic surgery with an open or laparoscopic/robotic approach, PEEP personalized by EIT or Pes allowed the achievement of a better intraoperative oxygenation compared to PEEP not individualized through EIT or Pes. PROSPERO REGISTRATION NUMBER: CRD 42021218306, 30/01/2023.


Assuntos
Respiração com Pressão Positiva , Tomografia Computadorizada por Raios X , Humanos , Impedância Elétrica , Ensaios Clínicos Controlados Aleatórios como Assunto , Respiração com Pressão Positiva/métodos , Oxigênio
3.
Cells ; 11(14)2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35883649

RESUMO

Impaired cerebral autoregulation (CA) may increase the risk of brain hypoperfusion in septic patients. Sepsis dysregulates the autonomic nervous system (ANS), potentially affecting CA. ANS function can be assessed through the pupillary light reflex (PLR). The aim of this prospective, observational study was to investigate the association between CA and PLR in adult septic patients. Transcranial Doppler was used to assess CA and calculate estimated cerebral perfusion pressure (eCPP) and intracranial pressure (eICP). An automated pupillometer (AP) was used to record Neurological Pupil Index (NPi), constriction (CV) and dilation (DV) velocities. The primary outcome was the relationship between AP-derived variables with CA; the secondary outcome was the association between AP-derived variables with eCPP and/or eICP. Among 40 included patients, 21 (53%) had impaired CA, 22 (55%) had low eCPP (<60 mmHg) and 15 (38%) had high eICP (>16 mmHg). DV was lower in patients with impaired CA compared to others; DV predicted impaired CA with area under the curve, AUROC= 0.78 [95% Confidence Interval, CI 0.63−0.94]; DV < 2.2 mm/s had sensitivity 85% and specificity 69% for impaired CA. Patients with low eCPP or high eICP had lower NPi values than others. NPi was correlated with eCPP (r = 0.77, p < 0.01) and eICP (r = −0.87, p < 0.01). Automated pupillometry may play a role to assess brain hemodynamics in septic patients.


Assuntos
Isquemia Encefálica , Sepse , Adulto , Hemodinâmica , Humanos , Estudos Prospectivos , Pupila/fisiologia
4.
Clin Imaging ; 77: 194-201, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33984670

RESUMO

BACKGROUND: The aim of this study was to quantify COVID-19 pneumonia features using CT performed at time of admission to emergency department in order to predict patients' hypoxia during the hospitalization and outcome. METHODS: Consecutive chest CT performed in the emergency department between March 1st and April 7th 2020 for COVID-19 pneumonia were analyzed. The three features of pneumonia (GGO, semi-consolidation and consolidation) and the percentage of well-aerated lung were quantified using a HU threshold based software. ROC curves identified the optimal cut-off values of CT parameters to predict hypoxia worsening and hospital discharge. Multiple Cox proportional hazards regression was used to analyze the capability of CT quantitative features, demographic and clinical variables to predict the time to hospital discharge. RESULTS: Seventy-seven patients (median age 56-years-old, 51 men) with COVID-19 pneumonia at CT were enrolled. The quantitative features of COVID-19 pneumonia were not associated to age, sex and time-from-symptoms onset, whereas higher number of comorbidities was correlated to lower well-aerated parenchyma ratio (rho = -0.234, p = 0.04) and increased semi-consolidation ratio (rho = -0.303, p = 0.008). Well-aerated lung (≤57%), semi-consolidation (≥17%) and consolidation (≥9%) predicted worst hypoxemia during hospitalization, with moderate areas under curves (AUC 0.76, 0.75, 0.77, respectively). Multiple Cox regression identified younger age (p < 0.01), female sex (p < 0.001), longer time-from-symptoms onset (p = 0.049), semi-consolidation ≤17% (p < 0.01) and consolidation ≤13% (p = 0.03) as independent predictors of shorter time to hospital discharge. CONCLUSION: Quantification of pneumonia features on admitting chest CT predicted hypoxia worsening during hospitalization and time to hospital discharge in COVID-19 patients.


Assuntos
COVID-19 , Feminino , Hospitalização , Humanos , Hipóxia/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2 , Tomografia Computadorizada por Raios X
5.
Respir Care ; 66(6): 983-993, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33906957

RESUMO

BACKGROUND: The assessment of diaphragmatic kinetics through tissue Doppler imaging (dTDI) was recently proposed as a means to describe diaphragmatic activity in both healthy individuals and intubated patients undergoing weaning from mechanical ventilation. Our primary aim was to investigate whether the diaphragmatic excursion velocity measured with dTDI at the end of a spontaneous breathing trial (SBT) was different in subjects successfully extubated versus those who passed the trial but exhibited extubation failure within 48 h after extubation. METHODS: We enrolled 100 adult subjects, all of whom had successfully passed a 30-min SBT conducted in CPAP of 5 cm H2O. In cases of extubation failure within 48 h after liberation from invasive mechanical ventilation, subjects were re-intubated or supported through noninvasive ventilation. dTDI was performed at the end of the SBT to assess excursion, velocity, and acceleration. RESULTS: Extubation was successful in 79 subjects, whereas it failed in 21 subjects. The median (interquartile range [IQR]) inspiratory peak excursion velocity (3.1 [IQR 2.0-4.3] vs 1.8 [1.3-2.6] cm/s, P < .001), mean velocity (1.6 [IQR 1.2-2.4] vs 1.1 [IQR 0.8-1.4] cm/s, P < .001), and acceleration (8.8 [IQR 5.0-17.8] vs 4.2 [IQR 2.4-8.0] cm/s2, P = .002) were all significantly higher in subjects who failed extubation compared with those who were successfully extubated. Similarly, the median expiratory peak relaxation velocity (2.6 [IQR 1.9-4.5] vs 1.8 [IQR 1.2-2.5] cm/s, P < .001), mean velocity (1.1 [IQR 0.7-1.7] vs 0.9 [IQR 0.6-1.0] cm/s, P = .002), and acceleration (11.2 [IQR 9.1-19.0] vs 7.1 [IQR 4.6-12.0] cm/s2, P = .004) were also higher in the subjects who failed extubation. CONCLUSIONS: In our setting, at the end of SBT, subjects who developed extubation failure within 48 h after extubation experienced a greater diaphragmatic activation compared with subjects who were successfully extubated. (ClinicalTrials.gov registration NCT03962322.).


Assuntos
Extubação , Desmame do Respirador , Adulto , Diafragma/diagnóstico por imagem , Humanos , Cinética , Respiração Artificial
6.
Ecotoxicol Environ Saf ; 200: 110772, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32464444

RESUMO

Recently two-dimensional nanomaterials, such as graphene and molybdenum disulfide (MoS2), have received much attention as adsorbent materials for the effective removal of organic contaminants. MoS2 is attracting attention, not only for its chemical-physical properties, but also for its wide availability in nature as a constituent of molybdenite. The aim of this investigation was to assess the effects of different MoS2 concentrations (5 × 10-1, 5 × 10-2 and 5 × 10-3 mg/ml) on the embryonated eggs of Gallus gallus domesticus, according to Beck method. We evaluated the toxic effect of the MoS2 powder purchased at Sigma-Aldrich indicated as "received" and MoS2 powder treated via mechanical milling indicated as "ball mille". Subsequently, the embryos were sacrificed at different times of embryonic development (11th, 15th and 19th day after incubation) in order to evaluate their embryotoxic and teratogenic effects. The alterations of the embryonic development were studied by morphological and immunohistochemical analysis of the tissues. The results obtained have shown the toxicity of both powders of MoS2 with a high percentage of deaths and growth delays. Moreover, the immunohistochemical analysis performed on several tissue sections showed a strong positivity to the anti-metallothionein1 antibody only for the erythrocytes.


Assuntos
Dissulfetos/química , Dissulfetos/toxicidade , Desenvolvimento Embrionário/efeitos dos fármacos , Molibdênio/química , Molibdênio/toxicidade , Nanopartículas/química , Nanopartículas/toxicidade , Animais , Embrião de Galinha , Relação Dose-Resposta a Droga , Grafite/química , Coração/efeitos dos fármacos , Coração/embriologia , Fígado/efeitos dos fármacos , Fígado/embriologia , Fígado/patologia , Pulmão/efeitos dos fármacos , Pulmão/embriologia , Pulmão/patologia , Tamanho da Partícula , Propriedades de Superfície
7.
Anesth Analg ; 130(3): 752-761, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31651455

RESUMO

BACKGROUND: In patients in the prone position, the reliability of pulse pressure variation and stroke volume variation (PPV and SVV) and the use of functional hemodynamic tests to predict fluid responsiveness have not previously been established. Perioperatively, in this setting, optimizing fluid management can be challenging, and fluid overload is associated with both intraoperative and postoperative complications. We designed this study to assess the sensitivity and specificity of baseline PPV and SVV, the tidal volume (VT) challenge (VTC) and the end-expiratory occlusion test (EEOT) in predicting fluid responsiveness during elective spinal surgery. METHODS: The study protocol was started during a period of intraoperative hemodynamic stability after prone positioning and before the administration of any vasopressor: (1) at baseline, the controlled ventilation was set at 6 mL/kg of predicted body weight (PBW) (T0); (2) patients underwent the first EEOT (EEOT6) by interrupting the mechanical ventilation for 30 seconds; (3) the ventilation was set again at 6 mL/kg PBW for 1 minute (T1); (4) the VTC was applied by increasing the VT up to 8 mL/kg PBW for 1 minute; (5) the ventilation was kept at 8 mL/kg PBW for 1 minute (T2); (6) a second EEOT (EEOT8) was performed; (7) the VT was reduced back to 6 mL/kg PBW for 1 minute (T3); (8) a fluid challenge of 250 mL of Ringer's solution was infused over 10 minutes. After each step, a complete set of hemodynamic measurements was recorded. RESULTS: Neither PPV and SVV values recorded at T3 nor the EEOT6 or the EEOT8 predicted fluid responsiveness. The change in PPV after VTC application predicted fluid responsiveness with an area under the curve of 0.96 (95% confidence interval, 0.87-1.00), showing a sensitivity of 95.2% and a specificity of 94.7%, using a cutoff increase of 12.2%. The change in SVV after VTC application predicted fluid responsiveness with an area under the curve 0.96 (95% confidence interval, 0.89-1.00) showing a sensitivity of 95.2% and a specificity of 94.7%, using a cutoff increase of 8.0%. A linear correlation between stroke volume index changes after fluid challenge administration and the changes in PPV and SVV after VTC application was observed (r = 0.71; P < .0001 and r = 0.68; P < .0001, respectively). CONCLUSIONS: In prone elective neurosurgical patients, the baseline values of PPV and SVV and the EEOT fail to predict fluid responsiveness, while the VTC is a very reliable functional hemodynamic test and could be helpful in guiding intraoperative fluid therapy.


Assuntos
Hidratação , Hemodinâmica , Monitorização Intraoperatória/métodos , Procedimentos Neurocirúrgicos , Posicionamento do Paciente , Decúbito Ventral , Respiração Artificial , Mecânica Respiratória , Solução de Ringer/administração & dosagem , Coluna Vertebral/cirurgia , Idoso , Pressão Sanguínea , Tomada de Decisão Clínica , Feminino , Hidratação/efeitos adversos , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos/efeitos adversos , Posicionamento do Paciente/efeitos adversos , Assistência Perioperatória , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Respiração Artificial/efeitos adversos , Solução de Ringer/efeitos adversos , Fatores de Risco , Volume Sistólico , Volume de Ventilação Pulmonar , Fatores de Tempo
8.
Respir Care ; 64(12): 1469-1477, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31455684

RESUMO

BACKGROUND: Early identification of noninvasive ventilation (NIV) outcome predictors in patients with COPD who are experiencing acute hypercapnic respiratory failure consequent to exacerbation or pneumonia is a critical issue. The primary aim of this study was to investigate the feasibility of performing diaphragmatic ultrasound for excursion, thickness, and thickening fraction in highly dyspneic subjects with COPD admitted to the emergency department for exacerbation or pneumonia, before starting NIV (T0) and after the first (T1) and second hour (T2) of treatment. Secondarily, we determined whether these variables predicted early NIV failure. METHODS: Adult subjects with COPD admitted to the emergency department for exacerbation or pneumonia requiring NIV were eligible. Right-sided diaphragmatic excursion, bilateral thickness, thickening fraction, and arterial blood gas analyses were performed at T0, T1, and T2. Feasibility was estimated by considering the number of subjects whose diaphragmatic function could be evaluated at each time point. At T2, subjects were classified in 2 subgroups according to early NIV failure, which was defined as the inability to achieve a pH ≥ 7.35; the ability to achieve pH ≥ 7.35 indicated NIV success. RESULTS: Of the 22 subjects enrolled, 21 underwent complete diaphragm ultrasound evaluation (ie, right excursion and bilateral thickness at T0, T1, and T2) for a total of 63 excursion and 126 thickness assessments. At T2, 12 NIV successes and 9 NIV failures were recorded. Diaphragmatic excursion was greater in NIV successes than in NIV failures at T0 (1.92 [1.22-2.54] cm versus 1.00 [0.60-1.41] cm, P = .02), at T1 (2.14 [1.76-2.77] cm versus 0.93 [0.82-1.27] cm, P = .007), and at T2 (1.99 [1.63-2.54] cm versus 1.20 [0.79-1.41] cm, P = .008), respectively. Diaphragmatic thickness and thickening fraction were similar in both groups. CONCLUSIONS: In our emergency department setting, diaphragm ultrasound was a feasible and reliable tool to monitor highly dyspneic acute hypercapnic respiratory failure subjects with COPD undergoing NIV. (ClinicalTrials.gov registration NCT03314883.).


Assuntos
Hipercapnia/diagnóstico por imagem , Ventilação não Invasiva , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Insuficiência Respiratória/diagnóstico por imagem , Ultrassonografia/métodos , Doença Aguda , Idoso , Idoso de 80 Anos ou mais , Diafragma/diagnóstico por imagem , Diafragma/fisiopatologia , Serviço Hospitalar de Emergência , Estudos de Viabilidade , Feminino , Humanos , Masculino , Doença Pulmonar Obstrutiva Crônica/fisiopatologia
9.
Curr Opin Crit Care ; 25(3): 259-265, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30946038

RESUMO

PURPOSE OF REVIEW: To provide an integrated clinical approach to the critically ill patients in shock. RECENT FINDINGS: The complexity behind shock mechanism has improved in the last decades; as consequence, conventional generalized practices have been questioned, in favour of different approaches, titrated to patient's individual response. Bedside clinical examination has been demonstrated to be a reliable instrument to recognize the mismatch between cardiac function and peripheral oxygen demand. Mottling skin and capillary refill time have been recently proposed using a semi-quantitative approach as reliable tool to guide shock therapy; lactate, ΔCO2 and ScVO2 are also useful to track the effect of the therapies overtime. Critical care echocardiography is useful to assess the source of the shock, to choice the correct the therapy and to customize the therapy. Finally, a more sophisticated and invasive calibrated monitoring should be promptly adopted in case of refractory or mixed shock state to titrate the therapy on predefined goals, avoiding the inappropriate use of fluids and vasoactive drugs. SUMMARY: Bedside haemodynamic assessment in critically ill patients should be considered an integrated approach supporting the decision-making process and should be based on clinical examination and critical care echocardiography.


Assuntos
Cuidados Críticos , Ecocardiografia , Hemodinâmica , Choque , Estado Terminal , Humanos , Choque/congênito , Choque/diagnóstico por imagem
10.
Crit Care ; 23(1): 31, 2019 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-30691523

RESUMO

BACKGROUND: Assessment of fluid responsiveness is problematic in intensive care unit (ICU) patients, in particular for those undergoing modes of partial support, such as pressure support ventilation (PSV). We propose a new test, based on application of a ventilator-generated sigh, to predict fluid responsiveness in ICU patients undergoing PSV. METHODS: This was a prospective bi-centric interventional study conducted in two general ICUs. In 40 critically ill patients with a stable ventilatory PSV pattern and requiring volume expansion (VE), we assessed the variations in arterial systolic pressure (SAP), pulse pressure (PP) and stroke volume index (SVI) consequent to random application of 4-s sighs at three different inspiratory pressures. A radial arterial signal was directed to the MOSTCARE™ pulse contour hemodynamic monitoring system for hemodynamic measurements. Data obtained during sigh tests were recorded beat by beat, while all the hemodynamic parameters were averaged over 30 s for the remaining period of the study protocol. VE consisted of 500 mL of crystalloids over 10 min. A patient was considered a responder if a VE-induced increase in cardiac index (CI) ≥ 15% was observed. RESULTS: The slopes for SAP, SVI and PP of were all significantly different between responders and non-responders (p < 0.0001, p = 0.0004 and p < 0.0001, respectively). The AUC of the slope of SAP (0.99; sensitivity 100.0% (79.4-100.0%) and specificity 95.8% (78.8-99.9%) was significantly greater than the AUC for PP (0.91) and SVI (0.83) (p = 0.04 and 0.009, respectively). The SAP slope best threshold value of the ROC curve was - 4.4° from baseline. The only parameter found to be independently associated with fluid responsiveness among those included in the logistic regression was the slope for SAP (p = 0.009; odds ratio 0.27 (95% confidence interval (CI95) 0.10-0.70)). The effects produced by the sigh at 35 cmH20 (Sigh35) are significantly different between responders and non-responders. For a 35% reduction in PP from baseline, the AUC was 0.91 (CI95 0.82-0.99), with sensitivity 75.0% and specificity 91.6%. CONCLUSIONS: In a selected ICU population undergoing PSV, analysis of the slope for SAP after the application of three successive sighs and the nadir of PP after Sigh35 reliably predict fluid responsiveness. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry, ACTRN12615001232527 . Registered on 10 November 2015.


Assuntos
Manuseio das Vias Aéreas/métodos , Hidratação/métodos , Respiração Artificial/métodos , Idoso , Manuseio das Vias Aéreas/tendências , Área Sob a Curva , Feminino , Hemodinâmica/fisiologia , Humanos , Unidades de Terapia Intensiva/organização & administração , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Respiração Artificial/tendências , Volume Sistólico/fisiologia
11.
Rev. bras. anestesiol ; 69(1): 20-26, Jan.-Feb. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-977422

RESUMO

Abstract Background and objectives: Transthoracic echocardiography may potentially be useful to obtain a prompt, accurate and non-invasive estimation of cardiac output. We evaluated whether non-cardiologist intensivists may obtain accurate and reproducible cardiac output determination in hemodynamically unstable mechanically ventilated patients. Methods: We studied 25 hemodynamically unstable mechanically ventilated intensive care unit patients with a pulmonary artery catheter in place. Cardiac output was calculated using the pulsed Doppler transthoracic echocardiography technique applied to the left ventricular outflow tract in apical 5 chamber view by two intensive care unit physicians who had received a basic Transthoracic Echocardiography training plus a specific training focused on Doppler, left ventricular outflow tract and velocity-time integral determination. Results: Cardiac output assessment by transthoracic echocardiography was feasible in 20 out of 25 enrolled patients (80%) and showed an excellent inter-operator reproducibility (Pearson correlation test r = 0.987; Cohen's K = 0.840). Overall, the mean bias was 0.03 L.min-1, with limits of agreement -0.52 and +0.57 L.min-1. The concordance correlation coefficient (ρc) was 0.986 (95% IC 0.966-0.995) and 0.995 (95% IC 0.986-0.998) for physician 1 and 2, respectively. The value of accuracy (Cb) of COTTE measurement was 0.999 for both observers. The value of precision (ρ) of COTTE measurement was 0.986 and 0.995 for observer 1 and 2, respectively. Conclusions: A specific training focused on Doppler and VTI determination added to the standard basic transthoracic echocardiography training allowed non-cardiologist intensive care unit physicians to achieve a quick, reproducible and accurate snapshot cardiac output assessment in the majority of mechanically ventilated intensive care unit patients.


Resumo Justificativa e objetivos: A ecocardiografia transtorácica pode ser potencialmente útil para obter uma estimativa rápida, precisa e não invasiva do débito cardíaco. Avaliamos se os intensivistas não cardiologistas podem obter uma determinação precisa e reprodutível do débito cardíaco em pacientes mecanicamente ventilados e hemodinamicamente instáveis. Métodos: Avaliamos 25 pacientes em unidade de terapia intensiva, mecanicamente ventilados, hemodinamicamente instáveis, com cateteres de artéria pulmonar posicionados. O débito cardíaco foi calculado com a técnica de ecocardiografia transtorácica com Doppler pulsátil aplicada à via de saída do ventrículo esquerdo no corte apical (5-câmaras) por dois médicos intensivistas que receberam treinamento básico em ecocardiografia transtorácica e treinamento específico focado em Doppler, via de saída do ventrículo esquerdo e determinação da integral de tempo-velocidade. Resultados: A avaliação do débito cardíaco pelo ecocardiograma transtorácico foi factível em 20 dos 25 pacientes inscritos (80%) e mostrou excelente reprodutibilidade entre operadores (teste de correlação de Pearson r = 0,987; K de Cohen = 0,840). No geral, o viés médio foi de 0,03 L.min-1, com limites de concordância de -0,52 e +0,57 L.min-1. O coeficiente de correlação de concordância (ρc) foi 0,986 (95% IC 0,966-0,995) e 0,995 (95% IC 0,986-0,998) para os médicos 1 e 2, respectivamente. O valor de precisão (Cb) da mensuração de COTTE foi de 0,999 para ambos os observadores. O valor de precisão (ρ) da mensuração de COTTE foi de 0,986 e 0,995 para os observadores 1 e 2, respectivamente. Conclusões: Um treinamento específico focado na determinação do Doppler e VTI, adicionado ao treinamento padrão em ecocardiografia transtorácica básica, permitiu que médicos não cardiologistas da unidade de terapia intensiva obtivessem uma avaliação rápida, reprodutível e precisa do débito cardíaco instantâneo na maioria dos pacientes mecanicamente ventilados em unidade de terapia intensiva.


Assuntos
Humanos , Masculino , Feminino , Adulto , Idoso , Respiração Artificial , Padrões de Prática Médica , Débito Cardíaco , Ecocardiografia Doppler de Pulso , Cuidados Críticos/métodos , Estado Terminal , Unidades de Terapia Intensiva , Pessoa de Meia-Idade
12.
Cardiol J ; 26(1): 56-65, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30234906

RESUMO

BACKGROUND: Aortic valve replacement (AVR) by sutureless prostheses is changing surgeon options, although which patients benefit most, as well as their possible economic impact is still to be defined. METHODS: Perceval-S prosthesis (LivaNova) is reserved, at the documented Institution, for patients at perceived high surgical risk. This retrospective analysis of outcome and resource consumption compared Perceval with other tissue valves. To clarify the comparison, only patients respecting 'instructions-for- use' of Perceval were reviewed. INCLUSION CRITERIA: > 65 years, +/- coronary artery bypass grafting, patent foramen ovale closure or myectomy. EXCLUSION CRITERIA: bicuspid, combined valve or aortic sur- gery. Costs were calculated per patient on a daily basis including preoperative tests, operating costs (hourly basis), disposables, drugs, blood components and personnel. RESULTS: The sutureless group (SU-AVR) had a higher risk profile than the sutured group (ST-AVR). Cardiopulmonary bypass (CPB) and cross-clamp times were significantly shorter in SU-AVR (isolated AVR: cross-clamp 52.9 ± 12.6 vs. 69 ± 15.3 min, p < 0.001; CPB 79.4 ± 20.3 vs. 92.7 ± 18.2 min, p < 0.001). Hospital mortality was 0.9% in SU-AVR and nil in ST-AVR, p = 0.489; intubation 7 (IQR 5-10.7) and 7 h (IQR 5-9), p = 0.785; intensive care unit 1 (IQR 1-1) and 1 day (IQR 1-1), p = 0.258; ward stay 5.5 (IQR 4-7) and 5 days (IQR 4-6), p = 0.002; pacemaker 5.7% (6/106) and 0.9% (1/109), p = 0.063, respectively. Hospital costs (excluding the prosthesis) were $12,825 (IQR 11,733-15,334) for SU-AVR and $12,386 (IQR 11,217-14,230) in ST-AVR, p = 0.055. CONCLUSIONS: Despite higher operative risks in SU-AVR, hospital mortality, morbidity and resource consumption did not differ. Operative times were shorter with the sutureless device and this improve- ment, along with more frequent ministernotomy, may have improved many postoperative aims.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Custos Hospitalares , Complicações Pós-Operatórias/epidemiologia , Procedimentos Cirúrgicos sem Sutura/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/economia , Estenose da Valva Aórtica/mortalidade , Análise Custo-Benefício , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/economia , Mortalidade Hospitalar/tendências , Humanos , Itália/epidemiologia , Masculino , Morbidade/tendências , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Procedimentos Cirúrgicos sem Sutura/economia , Resultado do Tratamento
13.
Braz J Anesthesiol ; 69(1): 20-26, 2019.
Artigo em Português | MEDLINE | ID: mdl-30413278

RESUMO

BACKGROUND AND OBJECTIVES: Transthoracic echocardiography may potentially be useful to obtain a prompt, accurate and non-invasive estimation of cardiac output. We evaluated whether non-cardiologist intensivists may obtain accurate and reproducible cardiac output determination in hemodynamically unstable mechanically ventilated patients. METHODS: We studied 25 hemodynamically unstable mechanically ventilated intensive care unit patients with a pulmonary artery catheter in place. Cardiac output was calculated using the pulsed Doppler transthoracic echocardiography technique applied to the left ventricular outflow tract in apical 5 chamber view by two intensive care unit physicians who had received a basic Transthoracic Echocardiography training plus a specific training focused on Doppler, left ventricular outflow tract and velocity-time integral determination. RESULTS: Cardiac output assessment by transthoracic echocardiography was feasible in 20 out of 25 enrolled patients (80%) and showed an excellent inter-operator reproducibility (Pearson correlation test r=0.987; Cohen's K=0.840). Overall, the mean bias was 0.03L.min-1, with limits of agreement -0.52 and +0.57L.min-1. The concordance correlation coefficient (ρc) was 0.986 (95% IC 0.966-0.995) and 0.995 (95% IC 0.986-0.998) for physician 1 and 2, respectively. The value of accuracy (Cb) of COTTE measurement was 0.999 for both observers. The value of precision (ρ) of COTTE measurement was 0.986 and 0.995 for observer 1 and 2, respectively. CONCLUSIONS: A specific training focused on Doppler and VTI determination added to the standard basic transthoracic echocardiography training allowed non-cardiologist intensive care unit physicians to achieve a quick, reproducible and accurate snapshot cardiac output assessment in the majority of mechanically ventilated intensive care unit patients.


Assuntos
Débito Cardíaco , Cuidados Críticos/métodos , Ecocardiografia Doppler de Pulso , Padrões de Prática Médica , Respiração Artificial , Adulto , Idoso , Estado Terminal , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA