Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Am J Cardiol ; 203: 1-8, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37478636

RESUMO

Given the increasing population eligible for transcatheter aortic valve implantation (TAVI), resource utilization has become an important focus in this setting. We aimed to estimate the change in the financial burden of TAVI therapy over 2 different periods. A probabilistic Markov model was developed to estimate the cost consequences of increased center experience and the introduction of newer-generation TAVI devices compared with an earlier TAVI period in a cohort of 6,000 patients. The transition probabilities and hospitalization costs were retrieved from the OBSERVANT (Observational Study of Effectiveness of AVR-TAVI procedures for severe Aortic steNosis Treatment) and OBSERVANT II (Observational Study of Effectiveness of TAVI with new generation deVices for severe Aortic stenosis Treatment) studies, including 1,898 patients treated with old-generation devices and 1,417 patients treated with new-generation devices. The propensity score matching resulted in 853 pairs, with well-balanced baseline risk factors. The mean EuroSCORE II (6.6% vs 6.8%, p = 0.76) and the mean age (82.0 vs 82.1 y, p = 0.62) of the early TAVI period and new TAVI period were comparable. The new TAVI period was associated with a significant reduction in rehospitalizations (-30.5% reintervention, -25.2% rehospitalization for major events, and -30.8% rehospitalization for minor events) and a 20% reduction in 1-year mortality. These reductions resulted in significant cost savings over a 1-year period (-€4.1 million in terms of direct costs and -€19.7 million considering the additional cost of the devices). The main cost reduction was estimated for rehospitalization, accounting for 79% of the overall cost reduction (not considering the costs of the devices). In conclusion, the introduction of new-generation TAVI devices, along with increased center experience, led to significant cost savings at 1-year compared with an earlier TAVI period, mainly because of the reduction in rehospitalization costs.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Implante de Prótese de Valva Cardíaca/métodos , Estresse Financeiro , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/cirurgia
2.
Int J Cardiol ; 357: 26-32, 2022 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-35306028

RESUMO

BACKGROUND: The PARTNER 3 trial demonstrated clinical benefits of transcatheter aortic valve implantation (TAVI) with the SAPIEN 3 device, over surgical aortic valve replacement (SAVR) in patients with severe symptomatic aortic stenosis (sSAS) at low risk of surgical mortality. Using PARTNER 3 outcomes and Italy-specific costs data, this cost-utility analysis from the perspective of the Italian National Health System aimed to determine the cost-effectiveness of SAPIEN 3 TAVI versus SAVR in low risk sSAS patients in Italy. METHODS: A two-stage cost-utility model was developed to estimate changes in both direct healthcare costs and health-related quality of life using TAVI with SAPIEN 3 compared with SAVR. Early adverse events associated with TAVI were captured utilising the PARTNER 3 dataset. These data fed into a Markov model that captured longer-term outcomes of patients, following TAVI or SAVR intervention. RESULTS: Analysis findings estimated that TAVI with SAPIEN 3 offers benefits over SAVR in terms of increased quality-adjusted life years (QALYs) with only a small increase in costs, representing an incremental cost-effectiveness ratio/QALY gained of €2989 per patient. The results were robust, with TAVI with SAPIEN 3 remaining cost-effective across several scenarios and in probabilistic sensitivity analyses. CONCLUSIONS: This model demonstrated that TAVI with SAPIEN 3 is likely to be cost effective compared with SAVR for the treatment of patients with sSAS who are at low risk of surgical mortality. These findings can inform policy makers to facilitate policy development in Italy on intervention selection for this patient population.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Análise Custo-Benefício , Implante de Prótese de Valva Cardíaca/economia , Humanos , Qualidade de Vida , Medição de Risco , Substituição da Valva Aórtica Transcateter/economia , Resultado do Tratamento
3.
Cardiovasc Revasc Med ; 15(8): 436-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24972513

RESUMO

BVS polymeric struts are transparent to the light so that the vessel wall contour can be easily visualized using optical coherence tomography (OCT). Therefore OCT represents a unique tool for both the evaluation of the resorption process and for the assessment of acute BVS mechanical failure. Similarly, the metal-free struts allow unrestricted coronary computed tomography angiography (CCTA), thus this non invasive method might become the gold standard for a non invasive assessment of BVS. In this case we show the ability of CCTA, performed with a low X-Ray dose, to provide a good evaluation of scaffold expansion. The quantitative measurements were in agreement with those obtained with OCT.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/uso terapêutico , Stents Farmacológicos , Eletrocardiografia , Tomografia de Coerência Óptica , Angioplastia Coronária com Balão/métodos , Eletrocardiografia/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Tomografia de Coerência Óptica/métodos , Tomografia Computadorizada Espiral/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA