Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Br J Soc Psychol ; 63(2): 745-766, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38010867

RESUMO

International carbon allocation confronts the conflict between efficiency and equality. Previous research based on the intergroup bias perspective has attributed carbon allocation preference to the defence of ingroup interests (i.e., national interests) while overlooking the critical role of trade-offs between competing moral values. Integrating the contingency theory of justice and moral philosophical theories of utilitarianism and egalitarianism, we proposed that the moral-values trade-off between utilitarianism and egalitarianism determines carbon allocation preference through justice reasoning. Analysis of large-scale survey datasets (Study 1) revealed that aggregated national endorsement of utilitarianism over egalitarianism predicted greater efficiency preference in total and per capita carbon emission levels. Study 2 demonstrated that experimentally manipulating endorsement of utilitarianism versus egalitarianism boosted efficiency (vs. equality) preference in carbon allocation, and justice reasoning characterized by enhanced efficiency-focused justice and diminished equality-focused justice accounted for these effects. Using a 'manipulation-of-mediator' design, Study 3 further confirmed the causal link in the mediation model. By highlighting the significance of moral trade-offs in shaping carbon allocation preference, this research not only provides a novel moral perspective in understanding debates on international carbon allocation but also has important implications for fostering international carbon abatement cooperation.


Assuntos
Teoria Ética , Princípios Morais , Humanos , Justiça Social
2.
Radiology ; 304(2): 473-482, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35503015

RESUMO

Background US elastography is a first-line assessment of liver fibrosis severity; however, its application is limited by its insufficient sensitivity in early-stage fibrosis detection and its measurements are affected by inflammation. Purpose To assess the sensitivity of US molecular imaging (USMI) in early-stage liver fibrosis detection and to determine whether USMI can specifically distinguish fibrosis regardless of inflammation when compared with two-dimensional (2D) shear-wave elastography (SWE). Materials and methods USMI and 2D SWE were performed prospectively (January to June 2021) in 120 male Sprague-Dawley rats with varying degrees of liver fibrosis and acute hepatitis and control rats. Liver sinusoidal capillarization was viewed at CD34-targeted USMI and quantitatively analyzed by the normalized intensity difference (NID). Data were compared by using a two-sided Student t test or one-way analysis of variance. Linear correlation analyses were used to evaluate the relationships between collagen proportionate area values and NID and liver stiffness measurement (LSM) values. Receiver operating characteristic curves were used to assess the diagnostic performance in detecting liver fibrosis. Results Both NID and LSM values showed good linear correlation with collagen proportionate area values (r = 0.91 and 0.87, respectively). No difference was observed between the areas under the receiver operating characteristic curve in detecting stage F0-F1 between USMI and 2D SWE (0.97 vs 0.91, respectively; P = .20). USMI depicted liver fibrosis at an early stage more accurately than 2D SWE (area under the curve, 0.97 vs 0.82, respectively; P = .01). Rats with hepatitis had higher liver stiffness values than control rats (9.83 kPa ± 0.79 vs 6.55 kPa ± 0.38, respectively; P < .001), with no difference in the NID values between control rats and rats with hepatitis (6.75% ± 1.43 vs 6.74% ± 0.86, respectively; P = .98). Conclusion Sinusoidal capillarization viewed at US molecular imaging helped to detect early-stage liver fibrosis more accurately than two-dimensional shear-wave elastography and helped assess fibrosis regardless of inflammation. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Barr in this issue.


Assuntos
Técnicas de Imagem por Elasticidade , Animais , Técnicas de Imagem por Elasticidade/métodos , Humanos , Inflamação/patologia , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Masculino , Imagem Molecular , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA