Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Inherit Metab Dis ; 31(6): 753-60, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18998239

RESUMO

AIM: We used intravascular ultrasound (IVUS) to characterize coronary artery involvement in patients with Fabry disease (FD). METHODS: Nine FD patients (5 women) were matched to 10 control patients (5 women) chosen from our IVUS database. Standard volumetric IVUS analyses were performed along with assessment of plaque echodensity. RESULTS: Plaques in FD patients were diffuse and hypoechogenic compared with more focal and more echogenic lesions in control patients. Echogenicity of plaques was significantly lower in FD patients (median 30.7 +/- 12.9 vs 55.9 +/- 15.7, p = 0.0052, mean 37.2 +/- 15.6 vs 66.2 +/- 13.3, p = 0.0014). Diffusiveness was assessed as differences between mean and median plaque burden versus the plaque burden in each of the analysed cross-sections. These differences were lower in FD vs controls (5.8 +/- 4.8 vs 8.7 +/- 6.6, p < 0.001 for mean, and 5.8 +/- 4.9 vs 8.8 +/- 7.3, p < 0.001 for median) indicating a more diffuse involvement. The occurrence of lipid cores was significantly higher in FD patients than in controls (2.4 +/- 1.5 vs 1.0 +/- 0.94, p = 0.02). CONCLUSION: IVUS showed diffuse hypoechogenic plaques in patients with FD. The explanation may be higher lipid content in plaques and accumulation of glycosphingolipid in smooth-muscle and endothelial cells.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Doença de Fabry/diagnóstico por imagem , Doença de Fabry/diagnóstico , Idoso , Estudos de Casos e Controles , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Endotélio Vascular/patologia , Doença de Fabry/complicações , Feminino , Fibroblastos/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Triexosilceramidas/metabolismo , Ultrassonografia
4.
Circulation ; 104(8): 856-9, 2001 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-11514368

RESUMO

BACKGROUND: The efficacy of coronary gamma-irradiation in preventing recurrent in-stent restenosis (ISR) is well established. However, brachytherapy may be less effective in very long, diffuse ISR lesions. METHODS AND RESULTS: We used serial intravascular ultrasound (IVUS) to study patients with long, diffuse ISR lesions (length, 36 to 80 mm) who were enrolled in (1) Long WRIST (Washington Radiation In-Stent Restenosis Trial), a double-blind, placebo-controlled trial of intracoronary gamma-irradiation (15 Gy at 2 mm from the source) and (2) high-dose (HD) Long WRIST, a registry that used a dose prescription of 18 Gy at 2 mm from the source. IVUS was performed using automated pullback (0.5 mm/s). Stent, lumen, and intimal hyperplasia were measured at 2-mm intervals. Complete postintervention and follow-up IVUS imaging was available in 30 irradiated and 34 placebo patients from Long WRIST and in 25 patients from HD Long WRIST. Stent length was longer in HD Long WRIST than in placebo or treated patients in Long WRIST (P=0.0064 and P=0.0125, respectively). Otherwise, baseline measurements were similar. At follow-up, the minimum lumen area was largest in the HD Long WRIST patients (4.0+/-1.4 mm(2)); areas were 2.9+/-1.0 mm(2) in irradiated patients in Long WRIST and 1.9+/-1.1 mm(2) in placebo patients in Long WRIST (P<0.005 for all comparisons). CONCLUSIONS: - Serial IVUS analysis shows that gamma-irradiation reduces recurrent in-stent neointimal hyperplasia in long, diffuse ISR lesions; however, it is even more effective when given at a higher dose.


Assuntos
Raios gama/uso terapêutico , Oclusão de Enxerto Vascular/prevenção & controle , Revascularização Miocárdica , Stents , Ultrassonografia de Intervenção , Braquiterapia/métodos , Doença das Coronárias/cirurgia , Relação Dose-Resposta à Radiação , Método Duplo-Cego , Oclusão de Enxerto Vascular/classificação , Oclusão de Enxerto Vascular/diagnóstico , Humanos , Pessoa de Meia-Idade , Revascularização Miocárdica/efeitos adversos , Revascularização Miocárdica/métodos , Fatores de Risco , Prevenção Secundária , Stents/efeitos adversos , Resultado do Tratamento , Grau de Desobstrução Vascular/efeitos da radiação
5.
Am J Cardiol ; 88(1): 1-4, 2001 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-11423049

RESUMO

Eighty-seven left main stenoses were evaluated by angiography and intravascular ultrasound. Intravascular ultrasound analysis included left main length (bifurcation to ostium), stenosis location, stenosis length, stenosis external elastic membrane, lumen, plaque & media cross-sectional area (CSA), plaque burden (plaque & media/external elastic membrane CSA), calcium arc, calcium length, eccentricity, and remodeling index (stenosis/reference external elastic membrane CSA). Long anatomic left main arteries (length > or =10 mm, n = 43) were compared with short anatomic left main arteries (length <10 mm, n = 44) regarding stenosis location. Ostial (proximal third of left main artery) (n = 32) and nonostial (midthird and distal third) stenoses (n = 55) were compared regarding stenosis morphology. Short anatomic left main arteries developed stenoses more frequently near the ostium (ostium 55%, bifurcation 38%). Conversely, long anatomic left main arteries developed stenoses more frequently near the bifurcation (ostium 18%, bifurcation 77%, p = 0.001). Ostial left main stenoses were more common in women (44% vs 20%, p = 0.02), had larger lumen area (6.2 +/- 2.2 vs 4.6 +/- 2.3 mm(2), p = 0.002), less plaque burden (62 +/- 15% vs 80 +/- 9%, p <0.0001), less calcification (arc = 78 +/- 65 degrees vs 195 +/- 101 degrees, p <0.0001), and more negative remodeling (remodeling index = 0.87 +/- 0.19 vs 1.01 +/- 0.21, p = 0.005) than nonostial left main stenoses. Most ostial left main stenoses were categorized as eccentric (97% vs 76%, p = 0.01). Short and long left main arteries develop stenoses at different locations. Stenosis morphology was significantly different in these 2 locations.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Ultrassonografia de Intervenção , Idoso , Distribuição de Qui-Quadrado , Angiografia Coronária , Vasos Coronários/anatomia & histologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Fatores de Risco
6.
Am J Cardiol ; 87(4): 473-5, A7, 2001 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-11179540

RESUMO

To study the relation in lesion morphology and composition between multiple vessels, intravascular ultrasound studies were performed on both vessels of 131 patients undergoing subsequent 2-vessel angioplasty. Because multiple stenoses in the same patient appear more dissimilar than similar, we conclude that local factors tend to be more important than patient factors in determining the lesion morphology.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Ultrassonografia de Intervenção , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença das Coronárias/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Fatores de Risco
7.
Am J Cardiol ; 84(9): 992-8, 1999 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-10569652

RESUMO

Remodeling occurs in diseased human coronary arteries; however, reports of remodeling in diseased autologous saphenous vein bypass graft (SVG) stenoses are inconsistent. Preintervention intravascular ultrasound and quantitative coronary angiography were used to study 104 SVG stenoses in 93 consecutive patients. Lesion site and proximal and distal reference segment measurements included vein graft, external elastic membrane, lumen, wall (vein graft minus lumen), and plaque (external elastic membrane minus lumen) areas. Three indexes of remodeling were assessed: (1) lesion site SVG (or external elastic membrane) area was compared with the average reference segment, (2) SVG area was correlated with the wall area and external elastic membrane area was correlated with the plaque area, and (3) the impact of excess plaque accumulation (at the stenosis compared with the reference segment) on lumen compromise was calculated. Overall, the ratio of lesion/reference vein graft area was 1.07 +/- 0.25; however, 23 lesions were classified as negative remodeling (ratio <0.9), 37 as intermediate remodeling (ratio between 0.9 and 1.1), and 44 as positive remodeling (ratio >1.1). Reference segment vein graft area correlated with wall area (r = 0.906, p <0.0001), and external elastic membrane area correlated with plaque area (r = 0.703, p <0.0001). Similarly, lesion site vein graft area correlated with wall area (r = 0.978, p <0.0001), and external elastic membrane area correlated with plaque area (r = 0.961, p <0.0001). The regression line relating delta lumen area to delta wall area was y = -0.22 x - 6.2 (r = 0.451, p <0.0001) and the regression line relating delta lumen to delta plaque area was y = -0.47 x - 4.5 (r = 0.572, p <0.0001). (A slope of 0 would indicate perfect positive remodeling and a slope of 1.0 no positive remodeling.) Diseased SVGs undergo positive and negative remodeling similar to native coronary arteries.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Endossonografia , Endotélio Vascular/patologia , Oclusão de Enxerto Vascular/diagnóstico , Complicações Pós-Operatórias/diagnóstico , Veias/transplante , Adulto , Idoso , Angiografia Coronária , Doença das Coronárias/diagnóstico , Tecido Elástico/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva
8.
Ann Thorac Surg ; 68(4): 1547-51, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10543566

RESUMO

Despite the fact that the coronary angiogram is the gold-standard in assessing a coronary artery stenosis for the purposes of clinical decision making, it has many limitations. Alternative methods are available. This article discusses three of these: intravascular ultrasound, coronary flow reserve, and fractional flow reserve.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Ultrassonografia de Intervenção , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Colateral/fisiologia , Angiografia Coronária , Circulação Coronária/fisiologia , Doença das Coronárias/fisiopatologia , Doença das Coronárias/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
9.
J Am Coll Cardiol ; 34(3): 707-15, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10483951

RESUMO

OBJECTIVES: The purpose of this study was to correlate angiographic and intravascular ultrasound (IVUS) findings in left main coronary artery (LMCA) disease and identify the predictors of coronary events at one year in patients with LMCA stenoses. BACKGROUND: Significant (> or =50% diameter stenosis [DS]) LMCA disease has a poor long-term prognosis. METHODS: One hundred twenty-two patients who underwent angiographic and IVUS assessment of the severity of LMCA disease and who did not have subsequent catheter or surgical intervention were followed for one year. Standard clinical, angiographic and IVUS parameters were collected. RESULTS: The quantitative coronary angiography (QCA) reference diameter (3.91 +/- 0.76 mm, mean +/- 1 SD) correlated moderately with IVUS (4.25 +/- 0.78 mm, r = 0.492, p = 0.0001). The lesion site minimum lumen diameter (MLD) (2.26 +/- 0.82 mm) by QCA correlated less well with IVUS (2.8 +/- 0.82 mm, r = 0.364, p = 0.0005). The QCA DS measured 42 +/- 16%. During the follow-up period, 4 patients died, none had a myocardial infarction, 3 underwent catheter-based LMCA intervention and 11 underwent bypass surgery. Univariate predictors of events (p < 0.05) were diabetes, presence of another lesion whether treated with catheter-based intervention or untreated with DS > 50% and IVUS reference plaque burden and lesion lumen area, maximum lumen diameter, MLD, plaque area and area stenosis. Using logistic regression analysis diabetes mellitus, an untreated vessel (with a DS > 50%) and IVUS MLD were independent predictors of cardiac events. CONCLUSIONS: In selected patients assessed by IVUS, moderate LMCA disease had a one-year event rate of only 14%. Intravascular ultrasound MLD was the most important quantitative predictor of cardiac events. For any given MLD, the event rate was exaggerated in the presence of diabetes or another untreated lesion (>50% DS).


Assuntos
Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Ultrassonografia de Intervenção , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Angiografia Coronária/estatística & dados numéricos , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Fatores de Tempo , Ultrassonografia de Intervenção/instrumentação , Ultrassonografia de Intervenção/métodos , Ultrassonografia de Intervenção/estatística & dados numéricos
10.
Am J Cardiol ; 83(11): 1518-23, 1999 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-10363864

RESUMO

Previous serial intravascular ultrasound (IVUS) analysis after percutaneous transluminal coronary angioplasty or directional coronary atherectomy showed (1) early (within 1 month) increase in arterial area, (2) late (1- to 6-month) decrease in arterial area, and (3) an increase in plaque area from immediately to 6 months after intervention. To further understand these findings, we used serial IVUS to study the relations between changes in arterial and plaque area during the follow-up period after coronary intervention. Serial IVUS was performed before intervention and immediately, 24 hours, 1 month, and 6 months after percutaneous transluminal coronary angioplasty (n = 35) or directional coronary atherectomy (n = 26) in 57 patients. Arterial, lumen, and plaque areas were measured at the lesion site with the smallest preintervention and follow-up lumen areas at all time points. The increase in plaque area in the first month after intervention was accompanied by an equal or greater increase in arterial area (r = 0.670, p <0.0001). There was a decrease in arterial area from 1 to 6 months after intervention, which correlated inversely with both the increase in plaque area (r = 0.434, p <0.0001) or arterial area (r = 0.515, p <0.0001) during the first month after intervention and directly with the 1- to 6-month increase in plaque area (r = 0.460, p <0.0001). Comparison of the late (1 to 6 months) and early (within 1 month) delta arterial versus delta plaque area regression lines suggested that the late decrease in arterial area was superimposed on the relation between delta arterial area and delta plaque area. These relations were especially strong in restenotic (vs nonrestenotic) lesions. The early increase and late decrease in stenosis arterial area and neointimal hyperplasia appear to be interrelated, especially in restenotic stenoses.


Assuntos
Angioplastia Coronária com Balão , Aterectomia Coronária , Túnica Íntima/patologia , Ultrassom , Artérias/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Seguimentos , Humanos , Hiperplasia/patologia , Fatores de Tempo , Ultrassonografia
11.
Am J Cardiol ; 83(10): 1427-32, 1999 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-10335756

RESUMO

Serial volumetric intravascular ultrasound (IVUS) was used to study de novo, nontreated left main coronary arteries (LMCAs) in 31 patients. Using an automated contour detection algorithm, analysis of 7.2 +/- 2.5 mm long segments included arterial, lumen, and plaque volumes and plaque burden (plaque/arterial volumes). During follow-up (7.7 +/- 2.4 months), the percent change in lumen volume correlated with the percent change in arterial volume (r = 0.897, p <0.0001), but not with the percent change in plaque volume (r = 0.066, p = 0.7263). Percent changes in arterial volume correlated with percent changes in plaque + media volume (r = 0.448, p = 0.0115), indicating arterial remodeling. However, there was a spectrum of responses ranging from inadequate remodeling (decrease in lumen volume despite no increase or a decrease in plaque volume: i.e., arterial shrinkage) to overcompensation (an increase in lumen volume despite an increase in plaque volume). Serial volumetric IVUS (1) confirms the existence of both positive and negative remodeling in LMCA, and (2) shows that in moderate LMCA disease, luminal changes resulted primarily from positive versus negative remodeling, not plaque progression and/or regression.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Ultrassonografia de Intervenção , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Progressão da Doença , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Estudos Prospectivos
12.
Am J Cardiol ; 78(11): 1202-9, 1996 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-8960575

RESUMO

Intravascular ultrasound (IVUS), which depicts both lumen and plaque, offers the potential to improve on the limitations of angiography for the assessment of the natural history of atherosclerosis and progression or regression of the disease. To facilitate measurements and increase the reproducibility of quantitative IVUS analyses, a computerized contour detection system was developed that detects both the luminal and external vessel boundaries in 3-dimensional sets of IVUS images. To validate this system, atherosclerotic human coronary segments (n = 13) with an area obstruction > or = 40% (40% to 61%) were studied in vitro by IVUS. The computerized IVUS measurements (areas and volumes) of the lumen, total vessel, plaque-media complex, and percent obstruction were compared with findings by manual tracing of the IVUS images and of the corresponding histologic cross sections obtained at 2-mm increments (n = 100). Both area and volume measurements by the contour detection system agreed well with the results obtained by manual tracing, showing low mean between-method differences (-3.7% to 0.3%) with SDs not exceeding 6% and high correlation coefficients (r = 0.97 to 0.99). Measurements of the lumen, total vessel, plaque-media complex, and percent obstruction by the contour detection system correlated well with histomorphometry of areas (r = 0.94, 0.88, 0.80, and 0.88) and volumes (r = 0.98, 0.91, 0.83, and 0.91). Systematic differences between the results by the contour detection system and histomorphometry (29%, 13%, -9%, and -22%, respectively) were found, most likely resulting from shrinkage during tissue fixation. The results of this study indicate that this computerized IVUS analysis system is reliable for the assessment of coronary atherosclerosis in vivo.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Aumento da Imagem/métodos , Adulto , Algoritmos , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Ultrassonografia de Intervenção
13.
Circulation ; 93(5): 924-31, 1996 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-8598083

RESUMO

BACKGROUND: Plaque distribution (eccentricity) may be a determinant of the success of transcatheter therapy, and certain devices may be better suited to treating severely eccentric lesions than others. However, no study has compared methods for assessing plaque distribution or systematically studied the validity of the angiographic assessment of plaque distribution. METHODS AND RESULTS: We studied 1446 native vessel target lesions in 1349 patients by intravascular ultrasound and coronary angiography. Angiographic and intravascular ultrasound criteria for lesion eccentricity were compared. Angiography showed that 795 of 1446 (55.0%) of target lesions were eccentric. When intravascular ultrasound was used, only 219 lesions (15.1%) had an arc of normal arterial wall within the lesion (equivalent to the pathological definition of lesion eccentricity). When an eccentricity index of >/= 3.0 was used, intravascular ultrasound classified 659 lesions (45.6%) as eccentric. The concordance rates of classification were only 47.7% (versus lesions containing an arc of normal arterial wall) and 53.8% (versus lesions with an ultrasound eccentricity index of >/= 3.0). More eccentric lesions had larger lumen cross-sectional areas, smaller plaque plus media and external elastic membrane cross-sectional areas, and smaller arcs of calcium, suggesting that they may represent less advanced atherosclerotic disease. CONCLUSIONS: There was significant discordance between angiography and ultrasound in assessing plaque distribution. Angiography appeared to detect lesion eccentricity more often than intravascular ultrasound. Furthermore, markedly eccentric lesions, in which there is an arc of normal vessel wall, were uncommon.


Assuntos
Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Ultrassonografia de Intervenção , Doença das Coronárias/patologia , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Am J Cardiol ; 75(17): 1267-70, 1995 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-7778553

RESUMO

IVUS measurements of stent and reference lumen dimensions and cross-sectional areas are highly reproducible. Furthermore, paramedical personnel can be trained to perform these measurements accurately. Thus, IVUS measurements may become the gold standard for the acute, chronic, and serial assessment of stent implantation procedures.


Assuntos
Veia Safena/transplante , Stents , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Veia Safena/diagnóstico por imagem
17.
J Am Coll Cardiol ; 16(6): 1393-7, 1990 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2121813

RESUMO

Transthoracic high frequency (7.5 MHz) ultrasonography can visualize the distal left anterior descending coronary artery. Thirty-seven patients were studied before and after administration of 0.4 mg sublingual nitroglycerin to determine whether this technique could quantitatively record changes in coronary artery diameter after intervention. Left anterior descending coronary artery diameter increased from 2.2 to 2.8 mm (p less than 0.05). The vasodilator response of this artery was compared with left ventricular mass index in normal subjects, patients with congestive cardiomyopathy and those with end-stage renal disease and left ventricular hypertrophy. Left anterior descending artery diameter increased 55% in normal subjects, 27% in patients with dilated cardiomyopathy and 10% in those with end-stage renal disease with left ventricular hypertrophy. These results demonstrate that high frequency ultrasound can detect nitroglycerin-induced changes in left anterior descending artery diameter. The percent increase is related to the diameter before nitroglycerin administration, which is related to the underlying diagnosis and left ventricular mass index.


Assuntos
Cardiomiopatia Dilatada/fisiopatologia , Vasos Coronários/fisiopatologia , Ecocardiografia/métodos , Hipertensão/fisiopatologia , Falência Renal Crônica/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatia Dilatada/diagnóstico por imagem , Circulação Coronária/efeitos dos fármacos , Vasos Coronários/efeitos dos fármacos , Feminino , Humanos , Hipertensão/complicações , Falência Renal Crônica/complicações , Masculino , Pessoa de Meia-Idade , Nitroglicerina , Valores de Referência , Reprodutibilidade dos Testes , Volume Sistólico/efeitos dos fármacos , Volume Sistólico/fisiologia , Vasodilatação/efeitos dos fármacos
19.
Am Heart J ; 109(2): 281-9, 1985 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-3871299

RESUMO

Intraoperative two-dimensional echocardiography (2DE) was performed in 15 patients during coronary artery bypass grafting (CABG) and in 14 patients during aortic (AVR) or mitral valve replacement (MVR) before and immediately after cardiopulmonary bypass by means of a 3.5 MHz transducer. Left ventricular ejection fraction (LVEF), end-diastolic (LVEDV) and end-systolic (LVESV) volumes were measured by a light pen system and biplane Simpson's rule from short-axis and apical two-chamber views. In seven patients with CABG and new abnormal Q waves or greater than 5% MB to total CPK ratio postoperatively, the mean LVEF decreased significantly (from 52 +/- 10 to 43 +/- 12%, p = 0.005). Patients undergoing MVR for mitral regurgitation showed, a significant decrease in LVEF (from 63 +/- 10 to 42 +/- 23%, p less than 0.025) and LVEDV (from 166 +/- 34 to 147 +/- 44 ml, p less than 0.05). Mean LVEF also decreased after AVR for aortic regurgitation (from 46 +/- 16 to 26 +/- 15%, p less than 0.05). Six patients with valve replacement and postoperative hypotension had the greatest decrease in intraoperative LVEF (from 50 +/- 12 to 24 +/- 10%, p less than 0.005). It is concluded that: Intraoperative 2DE can be used to assess immediate changes in left ventricular function after CABG or valve replacement. LVEF decreases significantly immediately after AVR for aortic regurgitation and MVR for mitral regurgitation. Intraoperative 2DE may identify those patients who can benefit from inotropic support in the immediate postoperative period after valve replacement.


Assuntos
Ponte de Artéria Coronária , Ecocardiografia , Ventrículos do Coração/fisiopatologia , Adulto , Idoso , Feminino , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/cirurgia , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA