Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
N Z Med J ; 132(1490): 17-25, 2019 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-30789885

RESUMO

AIM: Mortality rates of up to 38% at one year have been reported following surgery for neck of femur fractures. The aim of this review is to evaluate the post-operative mortality rates and trends over time for patients with fractured neck of femur at Waitemata District Health Board. METHOD: A retrospective cohort study of all patients who received surgery following a neck of femur fracture at Waitemata District Health Board between 2009 and 2016. Inpatient data was retrieved from electronic hospital records and mortality rates from the Ministry of Health, New Zealand. Analyses included crude mortality rates and trends over time, and time-to-theatre from presentation with neck of femur fracture. RESULTS: A total of 2,822 patients were included in the study; mean age 81.9 years, 70.4% female and 29.6% male. Overall post-operative crude rates for inpatient, 30-day and one-year mortality were 3.7%, 7.2% and 23.8% respectively. Adjusted analyses showed a statistically significant decrease in mortality rates between 2009 and 2016 at inpatient (p=0.001), 30 days (p=<0.001) and one year (p=<0.001) time periods. There was also a significant association between time-to-theatre and mortality at inpatient (p=0.002), 30 days (p=0.0001), and one year (p=0.0002) time periods. CONCLUSION: Mortality rates following surgery for fractured NOF have significantly improved over recent years at Waitemata District Health Board. Reduced time-to-theatre is associated with decreased inpatient, 30-day and one-year mortality.


Assuntos
Fraturas do Colo Femoral , Fixação de Fratura , Complicações Pós-Operatórias/mortalidade , Idoso , Idoso de 80 Anos ou mais , Efeitos Psicossociais da Doença , Feminino , Fraturas do Colo Femoral/economia , Fraturas do Colo Femoral/epidemiologia , Fraturas do Colo Femoral/mortalidade , Fraturas do Colo Femoral/cirurgia , Fixação de Fratura/métodos , Fixação de Fratura/reabilitação , Fixação de Fratura/estatística & dados numéricos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Mortalidade , Nova Zelândia/epidemiologia , Avaliação de Processos e Resultados em Cuidados de Saúde , Período Pós-Operatório , Estudos Retrospectivos , Fatores de Risco
2.
Clin Orthop Relat Res ; 473(12): 3752-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25910779

RESUMO

BACKGROUND: Templating is an important aspect of preoperative planning for total hip arthroplasty and can help determine the size and positioning of the prosthesis. Historically, templating has been performed using acetate templates over printed radiographs. As a result of the increasing use of digital imaging, surgeons now either obtain additional printed radiographs solely for templating purposes or use specialized digital templating software, both of which carry additional cost. QUESTIONS/PURPOSES: The purposes of this study was to compare acetate templating of digitally calibrated images on an LCD monitor to digital templating in terms of (1) accuracy; (2) reproducibility; and (3) time efficiency. METHODS: Acetate onlay templating was performed directly over digital radiographs on an LCD monitor and was compared with digital templating. Five separate observers participated in this study templating on 52 total hip arthroplasties. For the acetate templating, the digital images were magnified to the scaled reference on the templates provided by the manufacturer (ratio 1.2:1) before templating using a 25-mm marker as a reference. Both the acetate and digital templating results were then compared with the actual implanted components to determine accuracy. Interobserver and intraobserver variability was determined by an intraclass correlation coefficient. Observers recorded time to complete templating from the time of complete upload of patients' imaging onto the system to completion of templating. RESULTS: Both acetate and digital templates demonstrated moderate accuracy in predicting within one size of the eventual implanted acetabular cup (77% [199 of 260]; 70% [181 of 260], respectively; p = 0.050; 95% confidence interval [CI], 0.058-0.32), whereas acetate templating was better at predicting the femoral stem compared to digital templating (75% [195 of 260]; 60% [155 of 260], respectively; p < 0.001; 95% CI, 0.084-0.32). Acetate templating showed moderate to substantial interobserver agreement (cup intraclass correlation coefficient [ICC] = 0.55; 95% CI, 0.14-0.86; femoral ICC = 0.75; 95% CI, 0.39-0.95) and both methods showed almost perfect intraobserver agreement in reproducibility (acetate cup ICC = 0.82; 95% CI, 0.66-0.97; acetate femoral ICC = 0.86; 95% CI, 0.74-0.97; digital cup ICC = 0.82; 95% CI, 0.68-0.97; digital femoral ICC = 0.88; 95% CI, 0.77-1.0). Acetate templating could be performed more quickly (acetate mean 119 seconds; range, 37-220 seconds versus 154 seconds; range, 73-343 seconds; p < 0.001). CONCLUSIONS: Acetate onlay templating on digitally calibrated images can be a reliable substitute for digital templating using specialized software. It is quicker to perform and much less expensive. Hospitals and practices need not purchase expensive software, particularly at lower volume centers. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Acetatos , Artroplastia de Quadril/instrumentação , Desenho Assistido por Computador , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Pontos de Referência Anatômicos , Artroplastia de Quadril/economia , Desenho Assistido por Computador/economia , Análise Custo-Benefício , Eficiência , Custos de Cuidados de Saúde , Prótese de Quadril/economia , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese/economia , Reprodutibilidade dos Testes , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA