Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
2.
EuroIntervention ; 19(2): e155-e166, 2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-36809253

RESUMO

BACKGROUND: A bolus thermodilution-derived index of microcirculatory resistance (IMR) has emerged as the standard for assessing coronary microvascular dysfunction (CMD). Continuous thermodilution has recently been introduced as a tool to quantify absolute coronary flow and microvascular resistance directly. Microvascular resistance reserve (MRR) derived from continuous thermodilution has been proposed as a novel metric of microvascular function, which is independent of epicardial stenoses and myocardial mass. AIMS: We aimed to assess the reproducibility of bolus and continuous thermodilution in assessing coronary microvascular function. METHODS: Patients with angina and non-obstructive coronary artery disease (ANOCA) at angiography were prospectively enrolled. Bolus and continuous intracoronary thermodilution measurements were obtained in duplicate in the left anterior descending artery (LAD). Patients were randomly assigned in a 1:1 ratio to undergo either bolus thermodilution first or continuous thermodilution first. RESULTS: A total of 102 patients were enrolled. The mean fractional flow reserve (FFR) was 0.86±0.06. Coronary flow reserve (CFR) calculated with continuous thermodilution (CFRcont) was significantly lower than bolus thermodilution-derived CFR (CFRbolus; 2.63±0.65 vs 3.29±1.17; p<0.001). CFRcont showed a higher reproducibility than CFRbolus (variability: 12.7±10.4% continuous vs 31.26±24.85% bolus; p<0.001). MRR showed a higher reproducibility than IMR (variability 12.4±10.1% continuous vs 24.2±19.3% bolus; p<0.001). No correlation was found between MRR and IMR (r=0.1, 95% confidence interval: -0.09 to 0.29; p=0.305). CONCLUSIONS: In the assessment of coronary microvascular function, continuous thermodilution demonstrated significantly less variability on repeated measurements than bolus thermodilution.


Assuntos
Circulação Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Termodiluição , Microcirculação , Reprodutibilidade dos Testes , Resistência Vascular , Cateterismo Cardíaco , Vasos Coronários , Angiografia Coronária
3.
J Interv Cardiol ; 2021: 9971874, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34149324

RESUMO

BACKGROUND: To validate a simplified invasive method for the calculation of the index of microvascular resistance (IMR). METHODS: This is a prospective, single-center study of patients with chronic coronary syndromes presenting with nonobstructive coronary artery disease. IMR was obtained using both intravenous (IV) adenosine and intracoronary (IC) papaverine. Each IMR measurement was obtained in duplicate. The primary objective was the agreement between IMR acquired using adenosine and papaverine. Secondary objectives include reproducibility of IMR and time required for the IMR measurement. RESULTS: One hundred and sixteen IMR measurements were performed in 29 patients. The mean age was 68.8 ± 7.24 years, and 27.6% was diabetics. IMR values were similar between papaverine and adenosine (17.7 ± 7.26 and 20.1 ± 8.6, p=0.25; Passing-Bablok coefficient A 0.58, 95% CI -2.42 to 3.53; coefficient B 0.90, 95% CI -0.74 to 1.07). The reproducibility of IMR was excellent with both adenosine and papaverine (ICC 0.78, 95% CI 0.63 to 0.88 and ICC 0.93, 95% CI 0.87 to 0.97). The time needed for microvascular assessment was significantly shortened by the use of IC papaverine (3.23 (2.84, 3.78) mins vs. 5.48 (4.94, 7.09) mins, p < 0.0001). CONCLUSION: IMR can be reliably measured using IC papaverine with similar results compared to intravenous infusion of adenosine with increased reproducibility and reduced procedural time. This approach simplifies the invasive assessment of the coronary microcirculation in the catheterization laboratory.


Assuntos
Cateterismo Cardíaco , Doença da Artéria Coronariana , Microcirculação/fisiologia , Duração da Cirurgia , Resistência Vascular/fisiologia , Idoso , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/normas , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Simplificação do Trabalho
5.
Int J Cardiol ; 334: 1-9, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33933514

RESUMO

BACKGROUND: Morphological evaluation of coronary lesion length is a paramount step during invasive assessment of coronary artery disease. Likewise, the extent of epicardial pressure losses can be measured using longitudinal vessel interrogation with fractional flow reserve (FFR) pullbacks. We aimed to quantify the mismatch in lesion length between morphological (based on quantitative coronary angiography, QCA, and optical coherence tomography, OCT) and functional evaluations. METHODS: This is a prospective and multicenter study of patients evaluated by QCA, OCT and motorized fractional flow reserve pullbacks (mFFR). The difference in lesion length between the functional and anatomical evaluations was referred to as FAM. RESULTS: 117 patients (131 vessels) were included. Median lesion length derived from angiography was 16.05 mm [11.40-22.05], from OCT was 28.00 mm [16.63-38.00] and from mFFR 67.12 mm [25.38-91.37]. There was no correlation between QCA and mFFR lesion length (r = 0.124, 95% CI -0.168-0.396, p = 0.390). OCT lesion length did correlate with mFFR (r = 0.469, 95% CI 0.156-0.696, p = 0.004). FAM was strongly associated with the improvement in vessel conductance with percutaneous coronary intervention (PCI), higher mismatch was associated with lower post-PCI FFR. CONCLUSIONS: Lesion length assessment differs between morphological and functional evaluations. The morphological-functional mismatch in lesion length is frequent, and influences the results of PCI in terms of post-PCI FFR. Integration of the extent of pressure losses provides clinically relevant information that may be useful for clinical decision-making concerning revascularization strategy.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos
6.
AJR Am J Roentgenol ; 216(6): 1492-1499, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32876482

RESUMO

BACKGROUND. For clinical decision making, it was recently recommended that values of fractional flow reserve (FFR) derived from coronary CTA (FFRCT) be measured 1-2 cm distal to the stenosis, given the potential for overestimation of ischemia when FFRCT values at far distal segments are used. Supporting data are, however, lacking. OBJECTIVE. The purpose of the present study was to evaluate the diagnostic performance of FFRCT values measured 1-2 cm distal to the stenosis and at more distal locations relative to invasive FFR values. METHODS. FFRCT and invasive FFR values for 365 vessels in 253 patients identified from the Assessing Diagnostic Value of Noninvasive FFRCT in Coronary Care (ADVANCE) registry were prospectively assessed. FFRCT values were measured 1-2 cm distal to the stenosis and at the pressure wire position and far distal segments. The diagnostic accuracy of FFRCT was assessed on the basis of the ROC AUC. The AUC of FFRCT was calculated using FFRCT as an explanatory variable and an invasive FFR of 0.80 or less as the dichotomous dependent variable. RESULTS. The AUC of FFRCT values measured 1-2 cm distal to the stenosis (0.85; 95% CI, 0.80-0.88) was higher (p = .002) than that of FFRCT values measured at far distal segments (0.80; 95% CI, 0.76-0.84) and similar (p = .16) to that of FFRCT values measured at the pressure wire position (0.86; 95% CI, 0.81-0.89). FFRCT values measured 1-2 cm distal to the stenosis and at far distal segments had sensitivity of 87% versus 92% (p = .003), specificity of 73% versus 42% (p < .001), PPV of 75% versus 59% (p < .001), and NPV of 86% versus 85% (p = .72), respectively. Subgroup analyses of lesions of the left anterior descending coronary artery, left circumflex coronary artery, and right coronary artery all showed improved specificity and PPV (all p < .005) for FFRCT values measured 1-2 cm distal to the stenosis compared with values measured at the pressure wire position. However, the AUC was higher for measurements obtained 1-2 cm distal to the stenosis versus those obtained at far distal segments, for left anterior descending coronary artery lesions (p < .001) but not for left circumflex coronary artery lesions (p = .27) or right coronary artery lesions (p = .91). CONCLUSION. The diagnostic performance of FFRCT values measured 1-2 cm distal to the stenosis was higher than that of FFRCT values measured at far distal segments and was similar to that of FFRCT values measured at the pressure wire position in evaluating ischemic status, particularly for left anterior descending coronary artery lesions. CLINICAL IMPACT. The present study supports recent recommendations from experts to use FFRCT measured 1-2 cm distal to the stenosis, rather than measurements obtained at far distal segments, in clinical decision making.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
7.
Endosc Int Open ; 6(9): E1130-E1133, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30211303

RESUMO

A 66-year-old man underwent follow-up colonoscopy after colon polypectomy. The retroflexed view of the anal canal with white-light imaging revealed a whitish, slightly elevated lesion on the dentate line and an ill-defined flat lesion. A biopsy of the whitish elevation revealed squamous cell carcinoma (SCC), and endoscopic submucosal dissection (ESD) was planned. The lateral margin of the SCC was identified by spraying with Lugol's iodine, and the tumor was resected en bloc with no complications. The pathological findings were SCC in situ with parakeratosis in the whitish elevation and high-grade intraepithelial neoplasia in the ill-defined flat lesion, which exhibited a wide iodine-unstained area by chromoendoscopy. Early SCC in the anal canal is a rare gastrointestinal cancer, and Lugol chromoendoscopy helped visualize the tumor margin for ESD.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA