Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Circ Cardiovasc Imaging ; 9(10)2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27729359

RESUMO

BACKGROUND: The aim of this study was to determine the prognostic benefit of cardiac magnetic resonance (CMR) over transthoracic echocardiography (TTE) in ischemic cardiomyopathy and nonischemic dilated cardiomyopathy patients evaluated for primary prevention implantable cardioverter-defibrillator therapy. METHODS AND RESULTS: We enrolled 409 consecutive ischemic and dilated cardiomyopathy patients (mean age: 64±12 years; 331 men). All patients underwent TTE and CMR, and left ventricle end-diastolic volume, left ventricle end-systolic volume, and left ventricle ejection fraction (LVEF) were evaluated. In addition, late gadolinium enhancement was also assessed. All patients were followed up for major adverse cardiac events (MACE) defined as a composite end point of long runs of nonsustained ventricular tachycardia, sustained ventricular tachycardia, aborted sudden cardiac death, or sudden cardiac death. The median follow-up was 545 days. CMR showed higher left ventricle end-diastolic volume (mean difference: 43±22.5 mL), higher left ventricle end-systolic volume (mean difference: 34±20.5 mL), and lower LVEF (mean difference: -4.9±10%) as compared to TTE (P<0.01). MACE occurred in 103 (25%) patients. Patients experiencing MACE showed higher left ventricle end-diastolic volume, higher left ventricle end-systolic volume, and lower LVEF with both imaging modalities and higher late gadolinium enhancement per-patient prevalence as compared to patients without MACE. At multivariable analysis, CMR-LVEF ≤35% (hazard ratio=2.18 [1.3-3.8]) and the presence of late gadolinium enhancement (hazard ratio=2.2 [1.4-3.6]) were independently associated with MACE (P<0.01). A model based on CMR-LVEF ≤35% or CMR-LVEF ≤35% plus late gadolinium enhancement detection showed a higher performance in the prediction of MACE as compared to TTE-LVEF resulting in net reclassification improvement of 0.468 (95% confidence interval, 0.283-0.654; P<0.001) and 0.413 (95% confidence interval, 0.23-0.63; P<0.001), respectively. CONCLUSIONS: CMR provides additional prognostic stratification as compared to TTE, which may have direct impact on the indication of implantable cardioverter-defibrillator implantation.


Assuntos
Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/terapia , Desfibriladores Implantáveis , Ecocardiografia/métodos , Cardioversão Elétrica/instrumentação , Imagem Cinética por Ressonância Magnética , Isquemia Miocárdica/complicações , Prevenção Primária/instrumentação , Encaminhamento e Consulta , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/prevenção & controle , Cardiomiopatia Dilatada/etiologia , Cardiomiopatia Dilatada/fisiopatologia , Distribuição de Qui-Quadrado , Meios de Contraste/administração & dosagem , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Meglumina/administração & dosagem , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Análise Multivariada , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Prevenção Primária/métodos , Modelos de Riscos Proporcionais , Fatores de Risco , Volume Sistólico , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA