Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Open Heart ; 7(1)2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32467136

RESUMO

AIMS: Patients with de novo chest pain are usually investigated non-invasively. The new UK-National Institute for Health and Care Excellence (NICE) guidelines recommend CT coronary angiography (CTCA) for all patients, while European Society of Cardiology (ESC) recommends functional tests. We sought to compare the clinical utility and perform a cost analysis of these recommendations in two UK centres with different primary investigative strategies. METHODSRESULTS: We compared two groups of patients, group A (n=667) and group B (n=654), with new onset chest pain in two neighbouring National Health Service hospitals, each primarily following either ESC (group A) or NICE (group B) guidance. We assessed the clinical utility of each strategy, including progression to invasive coronary angiography (ICA) and revascularisation. We present a retrospective cost analysis in the context of UK tariff for stress echo (£176), CTCA (£220) and ICA (£1001). Finally, we sought to identify predictors of revascularisation in the whole population.Baseline characteristics in both groups were similar. The progression to ICA was comparable (9.9% vs 12.0%, p=0.377), with similar requirement for revascularisation (4.0% vs 5.0%.; p=0.532). The average cost of investigations per investigated patient was lower in group A (£279.66 vs £325.77), saving £46.11 per patient. The ESC recommended risk score (RS) was found to be the only predictor of revascularisation (OR 1.05, 95% CI 1.04 to 1.06; p<0.001). CONCLUSION: Both NICE and ESC-proposed strategies led to similar rates of ICA and need for revascularisation in discrete, but similar groups of patients. The SE-first approach had a lower overall cost by £46.11 per patient, and the ESC RS was the only variable correlated to revascularisation.


Assuntos
Angina Pectoris/diagnóstico por imagem , Regras de Decisão Clínica , Angiografia por Tomografia Computadorizada/normas , Angiografia Coronária/normas , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Testes de Função Cardíaca/normas , Guias de Prática Clínica como Assunto/normas , Idoso , Angina Pectoris/economia , Angina Pectoris/fisiopatologia , Angina Pectoris/terapia , Doença da Artéria Coronariana/economia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/terapia , Vasos Coronários/fisiopatologia , Redução de Custos , Análise Custo-Benefício , Feminino , Custos de Cuidados de Saúde , Fatores de Risco de Doenças Cardíacas , Humanos , Londres , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica/economia , Revascularização Miocárdica/normas , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco
3.
Open Heart ; 4(2): e000605, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28761679

RESUMO

OBJECTIVE: In this study, we assess the clinical and cost-effectiveness of stress echocardiography (SE), as well as the place of SE in patients with high pretest probability (PTP) of coronary artery disease (CAD). METHODS: We investigated 257 patients with no history of CAD, who underwent SE, and they had a PTP risk score >61% (high PTP). According to the National Institute for Health and Care Excellence guidance (NICE CG95, 2010), these patients should be investigated directly with an invasive coronary angiogram (ICA). We investigated those patients with SE initially and then with ICA when appropriate. Follow-up data with regard to Major Adverse Cardiac and Cerebrovascular Events (MACCE, defined as cardiovascular mortality, cerebrovascular accident (CVA), myocardial infarction (MI) and late revascularisation for acute coronary syndrome/unstable angina) were recorded for a period of 12 months following the SE. The tariff for SE and ICA is £300 and £1400, respectively. RESULTS: 106 patients had a positive SE (41.2%) and 61 of them (57.5%) had further investigation with ICA. 15 (24.6%) of these patients were revascularised. The average cost per patient for investigations was £654.09. If NICE guidance had been followed, the cost would have been significantly higher at £1400 (p<0.001). Overall, 5 MACCE (2.0%) were recorded; 4 (3.8%) in the group of positive SE (2 CVAs and 2 MIs) and 1 (0.7%) in the group of negative SE (1 CVA). There was no MI and no need for revascularisation in the negative SE group. CONCLUSION: Our approach to investigate patients who present with de novo chest pain and high PTP, with SE initially and subsequently with ICA when appropriate, reduces the cost significantly (£745.91 per patient) with a very low rate of MACCE. However, this study is underpowered to assess safety of SE.

4.
JACC Cardiovasc Imaging ; 8(3): 340-360, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25772838

RESUMO

Paravalvular regurgitation (PVR) is a frequent complication of transcatheter aortic valve replacement that has been shown to be associated with increased mortality. The objective of this article is to review the most up-to-date information about the assessment and management of PVR and to propose a new more comprehensive and unifying scheme for grading PVR severity. A multimodality, multiparametric, integrative approach including Doppler echocardiography, cineangiography, hemodynamic assessment, and/or cardiac magnetic resonance is essential to accurately assess the severity of PVR and the underlying etiology. Corrective procedures such as balloon post-dilation, valve-in-valve, or leak closure may be considered, depending on the severity, location, and etiology of PVR.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico , Valva Aórtica , Cateterismo Cardíaco/efeitos adversos , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Imagem Multimodal/métodos , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Cineangiografia , Consenso , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Incidência , Imageamento por Ressonância Magnética , Valor Preditivo dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
5.
Am J Physiol Heart Circ Physiol ; 306(9): H1371-83, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24531814

RESUMO

The objectives of this study were to assess the feasibility and accuracy of high-frequency speckle tracking echocardiography (STE) in a murine model of myocardial infarction (MI). STE is used clinically to quantify global and regional cardiac function, but its application in mice is challenging because of the small cardiac size and rapid heart rates. A high-frequency micro-ultrasound system with STE (Visualsonics Vevo 2100) was compared against magnetic resonance imaging (MRI) for the assessment of global left ventricular (LV) size and function after murine MI. Animals subjected to coronary ligation (n = 46) or sham ligation (n = 27) were studied 4 wk postoperatively. Regional and global deformation were also assessed. STE-derived LV ejection fraction (EF) and mass correlated well with MRI indexes (r = 0.93, 0.77, respectively; P < 0.001), as did STE-derived mass with postmortem values (r = 0.80, P < 0.001). Higher STE-derived volumes correlated positively with MRI-derived infarct size (P < 0.01). Global strain parameters were significantly reduced after MI (all P < 0.001) and strongly correlated with LV mass and MRI-derived infarct size as promising surrogates for the extent of remodeling and infarction, respectively (both P < 0.05). Regional strain analyses showed that radial strain and strain rate were relatively preserved in anterior basal segments after MI compared with more apical segments (P < 0.001); however, longitudinal strain and strain rate were significantly impaired both basally and distally (P < 0.001). Strain-derived parameters of dyssynchrony were significantly increased in the MI group (P < 0.01). Analysis time for STE was 210 ± 45 s with acceptable inter- and intraobserver variability. In conclusion, high-frequency STE enables quantitative assessment of regional and global function in the remodeling murine LV after MI.


Assuntos
Ecocardiografia/métodos , Infarto do Miocárdio/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular , Animais , Modelos Animais de Doenças , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Infarto do Miocárdio/fisiopatologia
6.
Eur Heart J Cardiovasc Imaging ; 14(12): 1132-9, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23708845

RESUMO

AIMS: Pocket-size imaging devices (PSID) are now available; their potential role in a hospital environment has been investigated but still remains undefined. METHODS AND RESULTS: We evaluated the effectiveness of PSID in 92 patients referred for bedside transthoracic echocardiogram (TTE). Patients were included where there was a focused clinical question: quantification of left ventricular function (LVF); presence of regional wall motion abnormalities (RWMA); evidence of pericardial effusion, exclusion of significant valve pathology. Each patient underwent an echocardiography evaluation using PSID and TTE. In 83 patients [k = 90%, 95% CI (82.2-95.4)], it was possible to answer the clinical question by PSID examination alone. There was agreement between the findings of PSID and TTE in 86 cases [79%; k = 47%, 95% CI (12.8-82.0)], in three cases, the clinical question was not answered by both modalities. When the clinical question was focused on LVF, the agreement was excellent [k = 96%, 95% CI (95.3-97.9)], as was the agreement in the detection of RWMA [k = 94.57%, 95% CI (82.4-95.1)]. There was also good concordance in the detection of valve pathology and pericardial effusion. Using PSID, the reduction in the scanning and reporting time was 66%. The cost-effectiveness analysis produced very favourable results: with PSE, we obtained an overall cost saving per scan of 76%, compared with TTE. CONCLUSION: This study demonstrates that PSID can provide a valuable alternative to TTE in the presence of focused clinical questions and can provide an efficient way of delivering a ward-based transthoracic echo service.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Ecocardiografia/economia , Ecocardiografia/instrumentação , Miniaturização/métodos , Sistemas Automatizados de Assistência Junto ao Leito/tendências , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/diagnóstico , Estudos de Coortes , Análise Custo-Benefício , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Ecocardiografia/métodos , Desenho de Equipamento/economia , Segurança de Equipamentos/economia , Feminino , Previsões , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sistemas Automatizados de Assistência Junto ao Leito/economia , Reprodutibilidade dos Testes , Reino Unido
7.
Eur Heart J Cardiovasc Imaging ; 14(9): 840-50, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23580556

RESUMO

Transcatheter aortic valve implantation (TAVI) provides an effective, less-invasive alternative treatment for patients with symptomatic severe aortic stenosis at high surgical risk. Echocardiography plays a central role in patient selection, procedural guidance, and evaluation, and in the detection of complications. This review describes the peri-interventional role of echocardiography during TAVI, outlines current limitations, and identifies future implications.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Ecocardiografia/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Seleção de Pacientes , Complicações Pós-Operatórias/diagnóstico por imagem , Índice de Gravidade de Doença , Ultrassonografia de Intervenção
9.
Cardiol Clin ; 25(2): 253-60, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17765104

RESUMO

Heart failure is exceedingly prevalent in the United States and in other developed countries. Treatment regimens are complex and now include electrical therapy. Methods for evaluating left ventricular dyssynchrony using echocardiography rather than QRS duration have been developed, with tissue Doppler velocity parameters being the most popular. Real-time three-dimensional echocardiography is another novel method for dyssynchrony evaluation that has potential advantages over existing techniques. The authors describe their experience with three-dimensional echocardiography dyssynchrony evaluation and offer insights into the direction that this technology must move to improve results.


Assuntos
Ecocardiografia Tridimensional/métodos , Disfunção Ventricular/diagnóstico por imagem , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Contração Miocárdica/fisiologia , Índice de Gravidade de Doença , Disfunção Ventricular/etiologia , Disfunção Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA