1.
G Ital Med Lav Ergon ; 33(3 Suppl): 65-8, 2011.
Artigo em Italiano | MEDLINE | ID: mdl-23393803

RESUMO

The Italian legislation on chemical agents has undergone significant changes. The aim of the study was to compare the results obatained from an environmental investigation and the use of the ARChi.MEDE model The results of the survey were treated with the UNI EN 689/1997 that showed an acceptable result, while according to the use A.R.Chi.M.E.D.E. a significant risk was obtained. Actually the mathematical model assess workers exposure without considering in the calculation the specific preventive measures (personal protective equipment, training, uptake of pollutants at the source) as contemplated by law. So the mathematical model showed the need of preventive measures in the studied work place.


Assuntos
Poluentes Ocupacionais do Ar/análise , Algoritmos , Exposição Ocupacional/análise , Poluentes Ocupacionais do Ar/efeitos adversos , Humanos , Exposição Ocupacional/efeitos adversos , Medição de Risco
2.
G Ital Med Lav Ergon ; 25(3): 350-2, 2003.
Artigo em Italiano | MEDLINE | ID: mdl-14582257

RESUMO

The dermal risk assessment requires simplified methodologies to understand the role played by the skin. The conceptual models proposed to this aim are founded on theoretical assumptions and experimental data, but their use in occupational settings shows many difficulties. For this end we have drawn up a check-list that includes six sessions and allows to obtain a preliminary dermal exposure evaluation subdivided on hazard bands.


Assuntos
Doenças Profissionais/epidemiologia , Exposição Ocupacional , Dermatopatias/epidemiologia , Humanos , Medição de Risco
3.
Med Lav ; 93(2): 73-9, 2002.
Artigo em Italiano | MEDLINE | ID: mdl-12087802

RESUMO

OBJECTIVES: RISKOFDERM is a research project whose aim is to develop instruments to assess and manage occupational dermal exposure to chemical substances. METHODS: The research, funded by the European Commission, involves 15 Institutes from 10 member countries; it is a continuation of the Dermal Exposure Network experience and consists of four interrelated parts. The first phase (Qualitative survey) assumed that dermal exposure can be extrapolated from one compound to another when it is task-based: therefore six Dermal Exposure Operation units (DEOu) were defined that lead back to the variety of occupational dermal exposure conditions and an extensive Questionnaire was developed for on-site surveys to perform standard observations in selected working situations (scenarios). RESULTS: The Italian group, participating in the research, obtained a set of observations relating to two "scenarios" in different working sectors: asphalt, ceramic and pottery workers, spectacle decorators and paint production: the aim was to verify the validity of the methodology in assessing the risk of percutaneous absorption, time, frequency and extension of skin exposure. CONCLUSIONS: From the observations made it was shown that the perception of risk was poor; it is necessary to rationalise work organization, and train and inform the employees on the correct use of personal protection devices.


Assuntos
Exposição Ocupacional/efeitos adversos , Pele/efeitos dos fármacos , Europa (Continente) , Humanos , Inquéritos e Questionários
4.
Toxicol Ind Health ; 17(1): 17-21, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12004921

RESUMO

To understand the dermal uptake of chemicals bound to soil and dust, information on the neat substance is helpful but does not seem sufficient. Because of its content of polycyclic aromatic hydrocarbons (PAHs) coal is suspected to be carcinogenic. However, experimental carcinogenity studies on coal dust never succeeded in demonstrating a higher incidence of cancer in treated animals. The aim of the study was to assess dermal penetration through human skin of PAHs from coal dust. A sample of coal dust was grinded and sieved, using the particle size of < 30 microm. An in vitro static diffusion cell system validated by in vitrolin vivo comparison has been used to study dermal penetration through human skin of PAHs from coal dust compared with their percutaneous absorption as pure compounds. No percutaneous penetration of PAHs was observed in the cells where coal dust was applied, while dermal penetration was demonstrated for PAHs applied in an acetone solution. Results agree with the literature that PAHs are poorly absorbed through the skin from solids. Dermal risk assessment of PAHs should take into account not only the degree and the extent of skin contamination, but also their bioavailability, which is heavily influenced by the physico-chemical characteristics of the matrix.


Assuntos
Carvão Mineral/análise , Poeira/análise , Hidrocarbonetos Policíclicos Aromáticos/farmacocinética , Pele/metabolismo , Administração Cutânea , Benzo(a)Antracenos/análise , Células/química , Humanos , Técnicas In Vitro , Masculino , Fenantrenos/análise , Hidrocarbonetos Policíclicos Aromáticos/administração & dosagem , Pele/patologia , Absorção Cutânea
5.
Environ Toxicol Pharmacol ; 8(2): 133-152, 2000 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-10867373

RESUMO

During the last few years the general interest in the percutaneous absorption of chemicals has increased. It is generally accepted that there is very few reliable quantitative and qualitative data on dermal exposure to chemicals in the general population and in occupationally exposed workers. In order to predict the systemic risk of dermally absorbed chemicals and to enable agencies to set safety standards, data is needed on the rates of percutaneous penetration of important chemicals. Standardization of in vitro tests and comparison of their results with the in vivo data could produce internationally accepted penetration rates and/or absorption percentages very useful for regulatory toxicology. The work of the Percutaneous Penetration Subgroup of EC Dermal Exposure Network has been focussed on the standardization and validation of in vitro experiments, necessary to obtain internationally accepted penetration rates for regulatory purposes. The members of the Subgroup analyzed the guidelines on percutaneous penetration in vitro studies presented by various organizations and suggested a standardization of in vitro models for percutaneous penetration taking into account their individual experiences, literature data and guidelines already in existence. During the meetings of Percutaneous Penetration Subgroup they presented a number of short papers of up to date information on the key issues. The objective was to focus the existing knowledge and the gaps in the knowledge in the field of percutaneous penetration. This paper is an outcome of the meetings of the Percutaneous Penetration Subgroup and reports the presentations on the key issues identified throughout the 3-year duration of the Dermal Exposure Network (1997-1999).

6.
Int Arch Occup Environ Health ; 72(8): 528-32, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10592005

RESUMO

OBJECTIVES: Percutaneous penetration of polycyclic aromatic hydrocarbons (PAHs) is affected by various factors connected to exposure conditions. The nature of the matrix, such as that of oil, can strongly affect their percutaneous penetration. Risk assessment should consider these effects. We examined the effect of matrix on percutaneous penetration of PAHs, particularly that of lubricating oil. METHODS: The test apparatus consisted of an in vitro static diffusion cell system using full-thickness monkey (Cercopithecus aetiops) skin as the membrane and saline solution with gentamycin sulfate and 4% bovine serum albumin as receptor fluid. Chemical analysis of PAHs in the samples obtained from cells was carried out by inverse-phase HPCL, and the results were read by spectrofluorimetry. RESULTS: Comparing the penetration of 13 PAHs from a lubricating oil and from acetone solution with artificial sweat resulted in a significantly slower passage from the oil matrix for acenaphthene, anthracene, phenanthrene, fluoranthene, naphthalene, pyrene, fluorene (Mann-Whitney U test, P < 0.05). No significant differences in the passage were found for chrysene because, in the test with oil, its concentration was very often below the detection limit. For benzo[a]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene, and benzo[a]pyrene it was possible to demonstrate a passage through the skin only when compounds were applied in acetone solution with artificial sweat. CONCLUSIONS: The results of the study suggest the necessity of dermal penetration data relevant for risk assessment, obtained under experimental conditions similar to the real exposure conditions.


Assuntos
Monitoramento Ambiental/métodos , Óleos Industriais/análise , Exposição Ocupacional/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Absorção Cutânea/fisiologia , Acetona/química , Animais , Bovinos , Chlorocebus aethiops , Cromatografia Líquida de Alta Pressão , Hidrocarbonetos Policíclicos Aromáticos/química , Medição de Risco , Espectrometria de Fluorescência , Suor/química , Viscosidade