Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Angew Chem Int Ed Engl ; : e202403583, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38682251

RESUMO

While levodopa (L-Dopa) is the primary treatment for alleviating Parkinson's disease (PD), its efficacy is hindered by challenges such as a short half-life and inconsistent plasma levels. As PD progresses, the rising need for increased and more frequent L-Dopa doses coupled with symptom fluctuations and dyskinesias underscores the urgency for improved comprehension of the interplay between L-Dopa levels and PD motor symptoms. Addressing this critical need, we present a decentralized testing method using a disposable biosensor strip and a universal slope (U-slope) calibration-free approach. This enables reliable, rapid, simple, and cost-effective decentralized L-Dopa measurements from capillary blood. A pilot study with PD persons demonstrates the ability to monitor real-time L-Dopa pharmacokinetics from fingerstick blood after oral L-Dopa-Carbidopa (C-Dopa) tablet administration. Correlating capillary blood L-Dopa levels with PD motor scores revealed a well-defined inverse correlation with temporal motor fluctuations. We compared the resulting dynamic capillary blood L-Dopa levels with plasma L-Dopa levels using the traditional but clinically impractical high-performance liquid chromatography technique. By providing timely feedback on a proper L-Dopa dosing regimen in a decentralized and rapid fashion, this new biosensing platform will facilitate tailored optimal L-Dopa dosing, towards improving symptom management and enhancing health-related quality of life.

2.
J Hazard Mater ; 360: 490-497, 2018 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-30144768

RESUMO

Methyl ethyl ketone (MEK) is a common and widely used industrial solvent. However, few studies have investigated its toxicity, or its effects as a contaminant in soil ecosystems. In this study, acute and chronic toxicity data for MEK were generated, and ecological risk based on a species sensitivity distribution was assessed. Seven soil organisms from six taxonomic groups were used for acute toxicity tests and five soil organisms from four taxonomic groups were used for chronic toxicity tests. Acute and chronic soil HC5 (hazardous concentration for 5% of species) values for MEK were estimated as 53.04 and 2.593 mg MEK/kg dry soil, respectively. This is the first study to conduct battery testing for MEK; it specifies hazardous concentrations, warns of the need for accident preparedness, and points to serious potential hazards of MEK at various levels of the soil ecosystem which can translate into greater environmental damage with implications for human health. The specific sensitivity levels determined may serve as a benchmark for establishing soil standards and strategies for ecosystem protection in the face of accidental contamination.


Assuntos
Poluentes do Solo/toxicidade , Animais , Artrópodes/efeitos dos fármacos , Artrópodes/fisiologia , Butanonas/toxicidade , Caenorhabditis elegans/efeitos dos fármacos , Caenorhabditis elegans/fisiologia , Clorófitas/efeitos dos fármacos , Clorófitas/crescimento & desenvolvimento , Ecossistema , Solanum lycopersicum/efeitos dos fármacos , Solanum lycopersicum/crescimento & desenvolvimento , Oligoquetos/efeitos dos fármacos , Oligoquetos/fisiologia , Oryza/efeitos dos fármacos , Oryza/crescimento & desenvolvimento
3.
Environ Pollut ; 236: 91-99, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29414378

RESUMO

Since the introduction of standardized nematode toxicity assays by the American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO), many studies have reported their use. Given that the currently used standardized nematode toxicity assays have certain limitations, in this study, we examined the use of a novel nematode offspring counting assay for evaluating soil ecotoxicity based on a previous soil-agar isolation method used to recover live adult nematodes. In this new assay, adult Caenorhabditis elegans were exposed to soil using a standardized toxicity assay procedure, and the resulting offspring in test soils attracted by a microbial food source in agar plates were counted. This method differs from previously used assays in terms of its endpoint, namely, the number of nematode offspring. The applicability of the bioassay was demonstrated using metal-spiked soils, which revealed metal concentration-dependent responses, and with 36 field soil samples characterized by different physicochemical properties and containing various metals. Principal component analysis revealed that texture fraction (clay, sand, and silt) and electrical conductivity values were the main factors influencing the nematode offspring counting assay, and these findings warrant further investigation. The nematode offspring counting assay is a rapid and simple process that can provide multi-directional toxicity assessment when used in conjunction with other standard methods.


Assuntos
Bioensaio/métodos , Caenorhabditis elegans/efeitos dos fármacos , Poluentes do Solo/toxicidade , Solo/química , Animais , Bioensaio/normas , Caenorhabditis elegans/crescimento & desenvolvimento , Feminino , Masculino , Padrões de Referência , Testes de Toxicidade/métodos
4.
Environ Monit Assess ; 189(12): 637, 2017 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-29143886

RESUMO

The soil quality of remediated land is altered and this land consequently exerts unexpected biological effects on terrestrial organisms. Therefore, field evaluation of such land should be conducted using biological indicators. Algae are a promising new biological indicator since they are a food source for organisms in higher soil trophic levels and easily sampled from the soil. Field evaluation of soil characteristics is preferred to be testing in laboratory conditions because many biological effects cannot be duplicated during laboratory evaluations. Herein, we describe a convenient and rapid algae-soaked disc seeding assay for assessing soil quality in the field based on soil algae. The collection of algae is easy and rapid and the method predicts the short-term quality of contaminated, remediated, and amended farm and paddy soils. The algae-soaked disc seeding assay is yet to be extensively evaluated, and the method cannot be applied to loamy sand soil in in situ evaluations. The algae-soaked disc seeding assay is recommended for prediction of soil quality in in situ evaluations because it reflects all variations in the environment. The algae-soaked disc seeding assay will help to develop management strategies for in situ evaluation.


Assuntos
Bioensaio/métodos , Monitoramento Ambiental/métodos , Poluentes do Solo/análise , Plantas , Solo
5.
Biosens Bioelectron ; 91: 128-135, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28006679

RESUMO

A disposable microfluidic amperometric dual-sensor was developed for the detection of glycated hemoglobin (HbA1C) and total hemoglobin (Hb), separately, in a finger prick blood sample. The accurate level of total Hb was determined through the measurements of the cathodic currents of total Hb catalyzed by a toluidine blue O (TBO)-modified working electrode. Subsequently, after washing unbound Hb in the fluidic channel of dual sensor with PBS, the cathodic current by only HbA1C captured on aptamer was monitored using another aptamer/TBO-modified working electrode in the channel. To modify the sensor probe, poly(2,2´:5´,5″-terthiophene-3´-p-benzoic acid) and a multi-wall carbon nanotube (MWCNT) composite layer (pTBA@MWCNT) was electropolymerized on a screen printed carbon electrode (SPCE), followed by immobilization of TBO for the total Hb probe and aptamer/TBO for the HbA1C probe, respectively. The characterization of each sensor surface was performed using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), X-ray photoelectron spectroscopy (XPS), quartz crystal microbalance (QCM), field-emission scanning electron microscopy (FE-SEM), and transmission electron microscopy (TEM). The experimental conditions affecting the analytical signal were optimized in terms of the amount of TBO, pH, temperature, binding time, applied potential, and the content ratio of monomer and MWCNT. The dynamic ranges of Hb and HbA1C were from 0.1 to 10µM and from 0.006 to 0.74µM, with detection limits of 82(±4.2)nM and 3.7(±0.8)nM, respectively. The reliability of the proposed microfluidic dual-sensor for a finger prick blood sample (1µL) was evaluated in parallel with a conventional method (HPLC) for point-of-care analysis.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Hemoglobinas Glicadas/análise , Hemoglobinas/análise , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Biossensoriais/economia , Corantes/química , Técnicas Eletroquímicas/economia , Eletrodos , Humanos , Técnicas Analíticas Microfluídicas/economia , Modelos Moleculares , Sistemas Automatizados de Assistência Junto ao Leito/economia , Reprodutibilidade dos Testes , Cloreto de Tolônio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA