1.
J Cardiovasc Electrophysiol ; 31(5): 1166-1174, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32141116

RESUMO

INTRODUCTION: Early evidence suggests that multipoint left ventricular pacing (MPP) may improve response to cardiac resynchronization therapy (CRT). It is unknown whether this benefit is sustained and cost-effective. We used real-world data to evaluate long-term impact of MPP-ON clinical status, heart failure hospitalizations (HFH) and costs. METHODS: The Italian registry on multipoint left ventricular pacing is a prospective, multicenter registry of patients implanted with MPP-enabled CRT devices. For this analysis, clinical and echocardiographic data were collected through 24 months and compared between patients with (MPP-ON) or without (MPP-OFF) early MPP activation at implant. The total cost of each HFH was estimated with national Italian reimbursement rates. RESULTS: The study included 190 MPP-OFF and 128 MPP-ON patients with similar baseline characteristics. At 1 and 2 years, the MPP-ON group had lower rates of HFH vs MPP-OFF (1-year hazard ratio [HR]: 0.14, P = .0014; 2-year HR: 0.38, P = .009). The finding persisted in a subgroup of patients with consistent MPP activation through follow-up (1-year HR: 0.19; P = .0061; 2-year HR: 0.39, P = .022). Total HFH per-patient costs were lower in the MPP-ON vs the MPP-OFF group at 1 year (€101 ± 50 vs €698 ± 195, P < .001) and 2 years (€366 ± 149 vs €801 ± 203, P = .038). More MPP-ON patients had ≥5% improvement in ejection fraction (76.8% vs 65.4%, P = .025) and clinical composite score (66.7% vs 47.5%, P = .01). CONCLUSIONS: In this multicenter clinical study, early MPP activation was associated with a significant reduction in cumulative HFH and related costs after 1 and 2 years of follow-up.


Assuntos
Terapia de Ressincronização Cardíaca/economia , Custos de Cuidados de Saúde , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Redução de Custos , Análise Custo-Benefício , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Custos Hospitalares , Hospitalização/economia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
2.
Europace ; 19(9): 1493-1499, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28407139

RESUMO

AIMS: Heart failure (HF) patients with implantable cardioverter-defibrillators (ICD) require admissions for disease management and out-patient visits for disease management and assessment of device performance. These admissions place a significant burden on the National Health Service. Remote monitoring (RM) is an effective alternative to frequent hospital visits. The EFFECT study was a multicentre observational investigation aiming to evaluate the clinical effectiveness of RM compared with in-office visits standard management (SM). The present analysis is an economic evaluation of the results of the EFFECT trial. METHODS AND RESULTS: The present analysis considered the direct consumption of healthcare resources over 12-month follow-up. Standard tariffs were applied to hospitalizations, in-office visits and remote device interrogations. Economic comparisons were also carried out by means of propensity score (PS) analysis to take into account the lack of randomization in the study design. The analysis involved 858 patients with ICD or CRT-D. Of these, 401 (47%) were followed up via an SM approach, while 457 (53%) were assigned to RM. The rate of hospitalizations was 0.27/year in the SM group and 0.16/year in the RM group (risk reduction =0.59; P = 0.0004). In the non-adjusted analysis, the annual cost for each patient was €817 in the SM group and €604 in the RM group (P = 0.014). Propensity score analysis, in which 292 RM patients were matched with 292 SM patients, confirmed the results of the non-adjusted analysis (€872 in the SM group vs. €757 in the RM group; P < 0.0001). CONCLUSION: There is a reduction in direct healthcare costs of RM for HF patients with ICDs, particularly CRT-D, compared with standard monitoring. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier, NCT01723865.


Assuntos
Desfibriladores Implantáveis/economia , Cardioversão Elétrica/economia , Custos de Cuidados de Saúde , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Visita a Consultório Médico/economia , Tecnologia de Sensoriamento Remoto/economia , Telemetria/economia , Idoso , Assistência Ambulatorial/economia , Distribuição de Qui-Quadrado , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Custos Hospitalares , Humanos , Itália , Masculino , Modelos Econômicos , Readmissão do Paciente/economia , Valor Preditivo dos Testes , Pontuação de Propensão , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Resultado do Tratamento
3.
Europace ; 19(8): 1349-1356, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27702861

RESUMO

AIMS: Patients receiving cardiac resynchronization therapy defibrillators (CRT-Ds) are likely to undergo one or more device replacements, mainly for battery depletion. We assessed the economic impact of battery depletion on the overall cost of CRT-D treatment from the perspectives of the healthcare system and the hospital. We also compared devices of different generations and from different manufacturers in terms of therapy cost. METHODS AND RESULTS: We analysed data on 1792 CRT-Ds implanted in 1399 patients in 9 Italian centres. We calculated the replacement probability and the total therapy cost over 6 years, stratified by device generation and manufacturer. Public tariffs from diagnosis-related groups were used together with device prices and hospitalization costs. Generators were from 3 manufacturers: Boston Scientific (667, 37%), Medtronic (973, 54%), and St Jude Medical (152, 9%). The replacement probability at 6 years was 83 and 68% for earlier- and recent-generation devices, respectively. The need for replacement increased total therapy costs by more than 50% over the initial implantation cost for hospitals and by more than 30% for healthcare system. The improved longevity of recent-generation CRT-Ds reduced the therapy cost by ∼6% in both perspectives. Among recent-generation CRT-Ds, the replacement probability of devices from different manufacturers ranged from 12 to 70%. Consequently, the maximum difference in therapy cost between manufacturers was 40% for hospitals and 19% for the healthcare system. CONCLUSIONS: Differences in CRT-D longevity strongly affect the overall therapy cost. While the use of recent-generation devices has reduced the cost, significant differences exist among currently available systems.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/economia , Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Remoção de Dispositivo/economia , Cardioversão Elétrica/economia , Cardioversão Elétrica/instrumentação , Fontes de Energia Elétrica/economia , Custos de Cuidados de Saúde , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Redução de Custos , Análise Custo-Benefício , Bases de Dados Factuais , Cardioversão Elétrica/efeitos adversos , Desenho de Equipamento , Falha de Equipamento , Gastos em Saúde , Insuficiência Cardíaca/diagnóstico , Humanos , Itália , Modelos Econômicos , Fatores de Tempo
4.
Europace ; 17(8): 1251-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25976906

RESUMO

AIMS: Device replacement at the time of battery depletion of implantable cardioverter-defibrillators (ICDs) may carry a considerable risk of complications and engenders costs for healthcare systems. Therefore, ICD device longevity is extremely important both from a clinical and economic standpoint. Cardiac resynchronization therapy defibrillators (CRT-D) battery longevity is shorter than ICDs. We determined the rate of replacements for battery depletion and we identified possible determinants of early depletion in a series of patients who had undergone implantation of CRT-D devices. METHODS AND RESULTS: We retrieved data on 1726 consecutive CRT-D systems implanted from January 2008 to March 2010 in nine centres. Five years after a successful CRT-D implantation procedure, 46% of devices were replaced due to battery depletion. The time to device replacement for battery depletion differed considerably among currently available CRT-D systems from different manufacturers, with rates of batteries still in service at 5 years ranging from 52 to 88% (log-rank test, P < 0.001). Left ventricular lead output and unipolar pacing configuration were independent determinants of early depletion [hazard ratio (HR): 1.96; 95% 95% confidence interval (CI): 1.57-2.46; P < 0.001 and HR: 1.58, 95% CI: 1.25-2.01; P < 0.001, respectively]. The implantation of a recent-generation device (HR: 0.57; 95% CI: 0.45-0.72; P < 0.001), the battery chemistry and the CRT-D manufacturer (HR: 0.64; 95% CI: 0.47-0.89; P = 0.008) were additional factors associated with replacement for battery depletion. CONCLUSION: The device longevity at 5 years was 54%. High left ventricular lead output and unipolar pacing configuration were associated with early battery depletion, while recent-generation CRT-Ds displayed better longevity. Significant differences emerged among currently available CRT-D systems from different manufacturers.


Assuntos
Desfibriladores Implantáveis/classificação , Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Fontes de Energia Elétrica/estatística & dados numéricos , Insuficiência Cardíaca/prevenção & controle , Indústrias/estatística & dados numéricos , Dispositivos de Terapia de Ressincronização Cardíaca/classificação , Dispositivos de Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Fontes de Energia Elétrica/classificação , Desenho de Equipamento , Falha de Equipamento , Análise de Falha de Equipamento/métodos , Análise de Falha de Equipamento/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Humanos , Itália/epidemiologia , Avaliação da Tecnologia Biomédica/métodos , Avaliação da Tecnologia Biomédica/estatística & dados numéricos