Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Comput Tomogr ; 18(2): 120-136, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37923578

RESUMO

BACKGROUND: Since the initial attempt to adapt the anatomical SYNTAX score (aSS) to coronary computed tomography angiography (CCTA), CCTA imaging technology has evolved, and is currently used as a "decision-maker" for revascularization strategy in complex coronary artery disease (CAD) and has rendered necessary some updating of the aSS to the CCTA modality. OBJECTIVES: The aim is to provide updated definitions of the aSS derived from CCTA in patients with complex CAD undergoing CABG. METHODS: The modifications of CCTA-aSS are the following; (i) updated definition and detection criteria of total occlusion (TO) in CCTA based on length assessment, (ii) inclusion of scoring points for serial bifurcations located in one single coronary segment. (iii) inclusion of weighing score points for lesions located distal to a TO, not visualized on conventional coronary angiography, but visible in CCTA, (iv) removal of thrombus and bridging collateral items from the weighing score, considering the limited diagnostic capability of CCTA in detecting these specific lesion characteristics. RESULTS: the updated CCTA-aSS was tested in a first-in-man study using the sole guidance of CCTA for the planning and performance of bypass surgery in complex CAD (n â€‹= â€‹114). An interobserver analysis showed excellent reproducibility (ICC â€‹= â€‹0.96, 95 â€‹% confidence interval 0.94-0.97). CONCLUSION: The updated CCTA-aSS was implemented in a cohort of patients with complex CAD undergoing CABG with the sole guidance of CCTA and FFRCT and the Inter-reproducibility of the analysis of the updated score was found excellent. The prognostic value of the modified CCTA-aSS will be examined in future studies.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia por Tomografia Computadorizada , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos
2.
EuroIntervention ; 12(16): 2001-2008, 2017 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-27973335

RESUMO

AIMS: The aim of this study was to investigate whether a Heart Team decision-making process regarding the choice of revascularisation strategy based on non-invasive coronary multislice computed tomography angiography (MSCT) assessment of coronary artery disease (CAD) is equivalent to the standard-of-care invasive angiography-based assessment in patients with multivessel CAD. METHODS AND RESULTS: The SYNTAX III Revolution trial is a prospective, multicentre, all-comers randomised trial that will randomise two Heart Teams to select between surgical and percutaneous treatment according to either an invasive conventional angiography or a non-invasive MSCT angiography assessment in patients with multivessel CAD. The treatment selection by each Heart Team will be guided by the SYNTAX score II calculation. The primary endpoint is the level of agreement according to kappa of the initial decision by the Heart Teams on the modality of the revascularisation based on MSCT and angiography assessments. Secondary endpoints include agreement on the number of vessels requiring treatment and the coronary segments in need of revascularisation. CONCLUSIONS: The SYNTAX III Revolution trial will provide valuable information regarding the ability of a purely non-invasive coronary anatomy assessment to select accurately the most appropriate revascularisation strategy for patients with multivessel CAD.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença
3.
Catheter Cardiovasc Interv ; 86(3): E140-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25914327

RESUMO

BACKGROUND: Three-dimensional (3D) quantitative coronary angiography (QCA) provides more accurate measurements by minimizing inherent limitations of two-dimensional (2D) QCA. The aim of this study was to compare the measurements between 2D and 3D QCA analyses in bifurcation lesions. METHODS AND RESULTS: A total of 114 cases with non-left main bifurcation lesions in the TRYTON pivotal IDE Coronary Bifurcation Trial (ClinicalTrials.gov: NCT01258972) were analyzed using a validated bifurcation QCA software (CAAS 5.10, Pie Medical Imaging, Maastricht, the Netherlands). All cases were analyzed in matched projections between pre- and post-procedure. The 2D analysis was performed using one of two angiographic images used for 3D reconstruction showing a larger distal bifurcation angle. In the treated segments (stent and balloon), there were no differences in minimal luminal diameter (MLD) between 2D and 3D, while diameter stenosis (DS) was significantly higher in 2D compared to 3D both pre-procedure and post-procedure (53.9% for 2D vs. 52.1% for 3D pre-procedure, P < 0.01; 23.2% for 2D vs. 20.9% for 3D post-procedure, P = 0.01). In the sub-segment level analysis, lengths of proximal main branch, distal main branch, and side branch were consistently shorter in 2D compared to 3D both pre-procedure and post-procedure. Using 3D QCA, the anatomic location of the smallest MLD or the highest DS was relocated to a different bifurcation sub-segment in a considerable proportion of the patients compared to when 2D-QCA was used (kappa values: 0.50 for MLD, 0.55 for DS). CONCLUSIONS: Our data showed differences in addressing anatomical severity and location of coronary bifurcation lesions between in vivo 2D and 3D QCA analyses. More studies are needed to investigate potential clinical benefits in using 3D approach over 2D QCA for the assessment of bifurcation lesions.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Humanos , Imageamento Tridimensional , Software , Resultado do Tratamento
4.
EuroIntervention ; 8(12): 1451-60, 2013 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-23680960

RESUMO

AIMS: Validation of new three-dimensional (3-D) bifurcation quantitative coronary angiography (QCA) software. METHODS AND RESULTS: Cardiovascular Angiography Analysis System (CAAS 5v10) allows 3-D angiographic reconstructions based on two or more 2-D projection images. Measurements for minimal lumen diameter (MLD), reference vessel diameter (RVD), percent diameter stenosis (DS) and bifurcation angle (BA) were validated against precision manufactured phantom bifurcations. Length measurements were validated against angiographic measurement catheters inserted into a plexiglas bifurcation phantom. In 3-D reconstructions based on two 2-D images, acquired at variable rotation and angulation, accuracy and precision (mean difference ± SD) of the 11-segment model for MLD, RVD and DS were 0.013±0.131 mm, -0.052±0.039 mm and -1.08±5.13%, respectively; inter-observer variability was 0.141 mm, 0.058 mm and 5.42%, respectively. Adding the antero-posterior (optimal) projection to these basic reconstructions resulted in reduced variability (0.101 mm, 0.041 mm and 3.93% for MLD, RVD and DS, p<0.01 for all) and showed a trend towards improved precision (0.109 mm, 0.031 mm and 4.26%, respectively, p>0.05 for all). In basic reconstructions, accuracy and precision for BA was -1.3±5.0°, whereas inter-observer variability was 7.5°; respective measures for length were 0.15±0.26 mm and 0.54 mm. Adding the antero-posterior projection resulted in decreased precision (0.47 mm, p<0.01) and increased variability (1.03 mm, p<0.01) for length measurements; precision (5.4°) and variability (7.9°) for BA did not change significantly (p>0.30). CONCLUSIONS: Advances in the methodology of 3-D reconstruction and quantitative analysis for bifurcation lesions translated into highly accurate, precise and reproducible measures of diameter, length and BA.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Validação de Programas de Computador , Algoritmos , Angiografia Coronária/instrumentação , Humanos , Imagens de Fantasmas , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
5.
EuroIntervention ; 7(11): 1326-35, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22433196

RESUMO

AIMS: To validate a new two dimensional (2-D) bifurcation quantitative coronary angiography (QCA) software. METHODS AND RESULTS: In the latest edition of the Cardiovascular Angiography Analysis System (CAAS 5.9; Pie Medical Imaging, Maastricht, The Netherlands) video-densitometric information is dynamically integrated into the edge-detection algorithm of 11- and 6-segment models to reduce overestimation of small diameters. Furthermore, automatic reference obstruction analysis was optimised. Values of the minimal lumen diameter (MLD), reference vessel diameter (RVD), percent diameter stenosis (DS) and bifurcation angle (BA) for the different bifurcation segment models were validated against precision manufactured plexiglass phantoms. In anteroposterior views, accuracy and precision (mean difference±SD) of 11- and 6-segment models for MLD were 0.013±0.082 mm vs. 0.003±0.100 mm, for RVD -0.030±0.047 mm vs. -0.029±0.045 mm and for DS -0.48±3.66% vs. -0.11±3.97%. In smaller vessel segments (true MLD <0.7 mm), MLD overestimation was reduced. Inter-observer variability for MLD, RVD and DS for either model was ≤0.052 mm, ≤0.043 mm and ≤2.24%, respectively. Agreement between models for MLD, RVD and DS was ±0.076 mm, ±0.021 mm and ±2.53%, respectively. Accuracy and precision for BA were -2.6±3.5°, and variability was ≤1.2°. Accuracy and precision for diameter-derived parameters were slightly decreased in projections with 30° rotation; BA precision dropped to 6.2°. CONCLUSIONS: MLD quantification is improved for true MLD <0.7 mm, resulting in highly accurate and precise diameter measurements over the entire range of phantom diameters. Automatic reference obstruction analysis provides highly accurate, precise and reproducible RVD and DS measurements.


Assuntos
Algoritmos , Angiografia Coronária/instrumentação , Angiografia Coronária/normas , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários , Angiografia Coronária/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/normas , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Modelos Cardiovasculares , Variações Dependentes do Observador , Imagens de Fantasmas , Valores de Referência , Reprodutibilidade dos Testes , Software
6.
Catheter Cardiovasc Interv ; 79(3): 361-8, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22072537

RESUMO

OBJECTIVES: To investigate the adequacy of visual estimate regarding the percent diameter stenosis (DS) in bifurcation lesions. BACKGROUND: Quantitative coronary angiography (QCA) is more accurate and precise compared to visual estimate in assessing stenosis severity in single-vessel lesions. METHODS: Thirty-six experts in the field of bifurcation PCI visually assessed the DS in cine images of five precision manufactured phantom bifurcation lesions, experts being blinded to the true values. Expert DS estimates were compared with the true values and they were also used to define the Medina class of each individual bifurcation. Results were pooled together both for proximal main vessel (PMV), distal main vessel (DMV) and side-branch (SB) segments and for vessel segments with similar DS values. RESULTS: Individual performance was highly variable among observers; pooled values and range of accuracy and precision were 2.79% (-6.67% to 17.33%) and 8.69% (4.31-16.25%), respectively. On average, DS was underestimated in the PMV (-1.08%, P = 0.10) and overestimated in the DMV (3.86% P < 0.01) and SB segments (5.58%, P < 0.01). Variability in visual estimates was significantly larger in lesions of medium severity compared to the clearly obstructive ones (P < 0.01); the latter were consistently overestimated. Inter-observer agreement was moderate (κ = 0.55) over the entire number of estimates. However, if the segments with true DS = 0% were excluded, agreement was diminished (κ = 0.27). Inter-observer agreement in Medina class was rather low (κ = 0.21). True bifurcation lesions were misclassified as non-true ones in 14/180 estimates. CONCLUSIONS: Visual assessment by experts is more variable and less precise in the analysis of bifurcation lesions compared to bifurcation QCA software.


Assuntos
Cineangiografia/instrumentação , Angiografia Coronária/instrumentação , Estenose Coronária/diagnóstico por imagem , Imagens de Fantasmas , Análise de Variância , Distribuição de Qui-Quadrado , Angiografia Coronária/métodos , Humanos , Variações Dependentes do Observador , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Software , Inquéritos e Questionários
7.
J Am Coll Cardiol ; 56(4): 272-7, 2010 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-20633818

RESUMO

OBJECTIVES: We aimed to assess the predictive value of the SYNTAX score (SXscore) for major adverse cardiac events in the all-comers population of the LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial. BACKGROUND: The SXscore has been shown to be an effective predictor of clinical outcomes in patients with multivessel disease undergoing percutaneous coronary intervention. METHODS: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the LEADERS trial (patients after surgical revascularization were excluded). Post hoc analysis was performed by stratifying clinical outcomes at 1-year follow-up, according to 1 of 3 SXscore tertiles. RESULTS: The 1,397 patients were divided into tertiles based on the SXscore in the following fashion: SXscore8 and 16 (SXhigh) (n=461). At 1-year follow-up, there was a significantly lower number of patients with major cardiac event-free survival in the highest tertile of SXscore (SXlow=92.2%, SXmid=91.1%, and SXhigh=84.6%; p<0.001). Death occurred in 1.5% of SXlow patients, 2.1% of SXmid patients, and 5.6% of SXhigh patients (hazard ratio [HR]: 1.97, 95% confidence interval [CI]: 1.29 to 3.01; p=0.002). The myocardial infarction rate tended to be higher in the SXhigh group. Target vessel revascularization was 11.3% in the SXhigh group compared with 6.3% and 7.8% in the SXlow and SXmid groups, respectively (HR: 1.38, 95% CI: 1.1 to 1.75; p=0.006). Composite of cardiac death, myocardial infarction, and clinically indicated target vessel revascularization was 7.8%, 8.9%, and 15.4% in the SXlow, SXmid, and SXhigh groups, respectively (HR: 1.47, 95% CI: 1.19 to 1.81; p<0.001). CONCLUSIONS: The SXscore, when applied to an all-comers patient population treated with drug-eluting stents, may allow prospective risk stratification of patients undergoing percutaneous coronary intervention. (LEADERS Trial Limus Eluted From A Durable Versus ERodable Stent Coating; NCT00389220).


Assuntos
Stents Farmacológicos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/tratamento farmacológico , Vigilância da População/métodos , Índice de Gravidade de Doença , Idoso , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/normas , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Radiografia , Valores de Referência , Medição de Risco
8.
Catheter Cardiovasc Interv ; 76(6): 817-23, 2010 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-20578164

RESUMO

BACKGROUND: The purpose of this study was to compare the performance of both conventional quantitative coronary angiography (QCA) and the dedicated three branch QCA model for bifurcations in the prediction of a functionally significant lesion according to fractional flow reserve (FFR) in patients with bifurcation lesions. METHODS: Twenty patients with bifurcation lesions underwent coronary angiography together with a functional evaluation of both the main branch and side-branch using FFR. QCA was performed off-line with both conventional QCA software (CAASII, Pie Medical Imaging, Maastricht, The Netherlands) and three branch QCA software (CAAS5, Pie Medical Imaging, Maastricht, The Netherlands). A stenosis was considered hemodynamically significant when the FFR value was ≤ 0.80 and anatomically significant when the diameter stenosis was >50%. The QCA and FFR data were correlated by means of the Pearson correlation. RESULTS: Eighteen bifurcation lesions were suitable for the QCA analysis. In the main vessel, a significant inverse correlation with FFR was seen with both conventional QCA (Pearson r = 0.52 for the MV, P = 0.02), and the three branch QCA model (Pearson r = 0.67 for the MV, P = 0.002). Conversely, in the side-branch, the correlation between QCA and FFR was only significant with the three branch QCA model (Pearson r = 0.57, P = 0.02 for the SB). CONCLUSIONS: In bifurcation lesions the correlation between the anatomic severity of a coronary stenosis and its functional significance appears to be somewhat higher when QCA is performed using the three branch model. This is most notable for side-branch stenoses which can be overestimated when using conventional QCA.


Assuntos
Angiografia Coronária , Estenose Coronária/diagnóstico , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Hemodinâmica , Humanos , Hiperemia/fisiopatologia , Modelos Cardiovasculares , Países Baixos , Projetos Piloto , Valor Preditivo dos Testes , Prognóstico , Interpretação de Imagem Radiográfica Assistida por Computador , Índice de Gravidade de Doença
9.
EuroIntervention ; 5(1): 50-6, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19577983

RESUMO

AIMS: The SYNTAX score has been designed to better anticipate the risks of percutaneous or surgical revascularisation, taking into account the functional impact of the coronary circulation with all its anatomic components including the presence of bifurcations, total occlusions, thrombus, calcification, and small vessels. The purpose of this paper is to describe the baseline assessment of the SYNTAX score in the Syntax randomised trial, the corelab reproducibility, the potential difference in score assessment between the investigator and the corelab, and to ascertain the impact on one-year outcome after either percutaneous coronary intervention (PCI) or coronary artery bypass surgery (CABG) in patients with complex coronary artery disease. METHODS AND RESULTS: To assess the reliability of Syntax scoring, 100 diagnostic angiograms from the Syntax trial were randomly selected and assessed independently by two observers. Intra-observer variability was assessed by analysing 91 sets of angiograms after an interval of at least eight weeks by one of the observers. Clinical outcomes in the randomised cohort of the Syntax trial up to one year are presented with stratification by tertile group of the SYNTAX score. The weighted kappa value for the inter-observer reproducibility on the global score was 0.45, while the intra-observer weighted kappa value was 0.59. The SYNTAX score as calculated by investigators consistently underscored the corelab score by 3.4 points. When the Syntax randomised cohort was stratified by tertiles of the SYNTAX score, there were similar or non-significantly different MACCE rates in those with low or intermediate scores; however in the top tertile the MACCE rate was greater in those receiving PCI compared to CABG. CONCLUSIONS: The SYNTAX score is a visual coronary score with an acceptable corelab reproducibility that has an impact on the one-year outcome of those having PCI, whereas it has no effect on the one-year outcome following surgical revascularisation. The SYNTAX score tool is likely to be useful in a wide range of patients with complex coronary disease.


Assuntos
Angioplastia Coronária com Balão , Angiografia Coronária , Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Angioplastia Coronária com Balão/efeitos adversos , Doenças Cardiovasculares/etiologia , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Europa (Continente) , Humanos , Estudos Multicêntricos como Assunto , Variações Dependentes do Observador , Valor Preditivo dos Testes , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema de Registros , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
10.
J Am Coll Cardiol ; 47(6): 1134-42, 2006 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-16545642

RESUMO

OBJECTIVES: Our purpose was to assess noninvasive imaging in detection of subclinical atherosclerosis and to examine novel invasive modalities to describe prevalence and temporal changes in putative characteristics of "high-risk" plaques. BACKGROUND: Conventional coronary imaging cannot identify "high-risk" lesions. METHODS: Conventional (quantitative angiography and intravascular ultrasound [IVUS]) and novel imaging (IVUS-based palpography and gray scale echogenicity) were performed at baseline and 6 months later in 67 patients with diverse clinical presentations. Different imaging techniques were compared within a common segment defined by multislice computed tomography (MSCT). RESULTS: Compared with IVUS, the sensitivity, specificity, and positive and negative predictive value of MSCT for detecting significant plaque was 86%, 69%, 90%, and 61%, respectively. In coronary arteries with <50% stenosis, there were no temporal changes in luminal and plaque dimensions measured by quantitative coronary angiography or IVUS; however, a significant reduction in abnormal strain pattern was detected on palpography (density high strain spots/cm: 1.6 +/- 1.5 vs. 1.2 +/- 1.4, p = 0.0123. These changes were mainly related to significant changes in patients who presented with ST-segment elevation myocardial infarction. The assessment of plaque echogenicity showed no temporal changes. There were no correlations between circulating biomarkers and quantifiable imaging parameters. CONCLUSIONS: Mild angiographic disease is associated with large atherosclerotic plaques on MSCT. Conventional invasive coronary imaging reveals static luminal and plaque dimensions on standard medical therapy with plaque hypoechogenicity remaining unchanged over the 6-month period. By contrast, palpography measurements of strain correlate with clinical presentation and significantly decrease on standard medical therapy. Novel imaging modalities, such as palpography, might provide insights into plaque biology and might eventually serve as intermediate end points in interventional trials.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Ultrassonografia de Intervenção , Angiografia Coronária/métodos , Doença da Artéria Coronariana/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA