1.
J Microbiol Methods ; 62(3): 293-302, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15963585

RESUMO

Regulatory lipids from the airway surface readily form aerosols that can be recovered non-invasively by cooling expired breath to form breath condensate (BC). Regulatory lipids have been detected previously utilizing enzyme-linked-immunosorbent serologic assay (ELISA). Here we test the feasibility of assessment of regulatory lipids in BC by mass spectrometry so presently unknown lipid regulatory components can be detected without addition of specific antibodies as in the ELISA procedure. Baseline regulatory lipids were detected in >pg/mL BC in control animals or human lung tissue culture cells. In nearly every case animals exposed to toxins or infectious bacteria showed increases in the BC regulatory components. Lipids were recovered from BC by solid phase extraction. Phosphatidylcholine (PC) based lipids were detected as the progenitor (parent) ions of isomers that fragmented in producing product positive ions at m/z 184 (of phosphocholine) in tandem MS using capillary HPLC and electrospray ionization. BC eicosanoids such as prostaglandins, thromboxane, and isoprostanes require capillary gas chromatography for separation and detection that necessitates methoximation, pentafluorobenzyl (PFB) ester formation, and trimethyl silylation of hydroxyls prior to gas chromatography/ion trap tandem mass spectrometry of negative ions after chemical ionization (NICI). Tetradeuterated internal standards were utilized for quantitation with the GC/NICI/MS. Changes in concentrations of lipids and eicosanoids were observed in piglets, and rats exposed to aerosolized 100 mug/kg lipopolysaccharide (LPS), or 50 mug/kg and 150 mug/kg aerosolized Staphylococcal enterotoxin B (SEB) in BC as well as in human THP-1 cell culture cell supernatants and bronchoalveolar lavage (BAL) samples in rats. Responses of the molecular species of phosphatidylcholines (PCs), platelet activating factors (PAFs) and specific eicosanoids correlated to the toxin and bacterial infections suggesting that patterns of differential responses could be detected with further experimentation. Initial targets included prostaglandins (PGE(2), PGF(2alpha)), thromboxane (TXB2), and prostacyclin (as 6-Keto PGF(1alpha)) that show differential responses to inflammation, the leukotriene (LTB4) and PGD2 for allergic responses, isoprostanes (8-iso-PGF(2alpha)) for free radical oxidative stress responses, and HETEs for differential lipoxygenase activities. PAFs and lysoPAFs have been shown to increase with inflammation and in the feasibility experiments reported here. Preliminary studies show pulmonary responses of piglets to intrathecal exposure of toxicants (LPS and SEB) or infections with Actinobacillus pleuropneumoniae induce increased levels of lipids and two eicosanoids with the suggestion that differential patterns might be detected with expanded testing. Preliminary experience indicates numerous other eicosanoids were available for assay in BC. This suggests an important potential application of BC to observe a wide array of factors to establish comprehensive profiles for physiological and pathophysiological states. Ultimately this technique could be used as a non-invasive possibly presymptomatic assessment of pulmonary pathobiology.


Assuntos
Testes Respiratórios/métodos , Lipídeos/análise , Pneumopatias/diagnóstico , Actinobacillus pleuropneumoniae/patogenicidade , Animais , Linhagem Celular , Cromatografia Líquida de Alta Pressão , Eicosanoides/análise , Enterotoxinas/toxicidade , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Lipopolissacarídeos/toxicidade , Pneumopatias/metabolismo , Fosfolipídeos/análise , Fosfolipídeos/química , Fator de Ativação de Plaquetas/análogos & derivados , Fator de Ativação de Plaquetas/análise , Ratos , Infecções Respiratórias/diagnóstico , Infecções Respiratórias/metabolismo , Espectrometria de Massas por Ionização por Electrospray , Sus scrofa
2.
J Pharmacol Toxicol Methods ; 47(1): 1-10, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12387933

RESUMO

INTRODUCTION: The evaluation of pulmonary physiological measurements in laboratory animals is an essential tool in many biomedical and toxicological research areas. Recently, an unrestrained single chambered whole-body plethysmograph that utilizes a barometric analysis technique to quantify pulmonary physiological values has gained widespread use. However, results generated with the single chamber plethysmograph have come under increased scrutiny because airflow in the lung is indirectly measured. The purpose of the present study was to use mice with known interstrain differences in pulmonary physiology (A/J, BALB/c, CD-1, and B6C3F1) and compare the physiological data generated with a single chamber plethysmograph to data obtained in the widely accepted double chamber noninvasive airway mechanics (NAM) plethysmograph in which the animals are restrained. METHODS: Animals were placed into the plethysmographs and baseline physiological data acquired. The mice were then subjected to challenge with aerosols generated from isotonic saline (control) and methacholine solutions of increasing concentration (2.5-320 mg/ml) for 3 min for determination of the concentration of methacholine that induced a 200% increase in airway resistance (PC(200)R). RESULTS: Repeated physiological measurements on the same animals in both the single and double chamber plethysmographs demonstrated that each instrument generated reproducible baseline physiological data. However, comparison of physiological data generated with the double-chambered instrument to that generated with the single chamber plethysmograph revealed several significant differences. While the single chamber plethysmograph appeared to give inaccurate measurements of tidal volume, it provided much better analysis of airway reactivity based on PC(200)R results. In contrast, the double chamber plethysmograph provided accurate physiological data such as tidal volume and respiratory rate, but provided inaccurate and irreproducible airway reactivity results based on PC(200)R. DISCUSSION: Our results indicate that the choice of single or double chamber plethysmograph for physiological measurements should be linked to the study objectives and the type of data required.


Assuntos
Imobilização/fisiologia , Pulmão/fisiologia , Pletismografia Total , Administração por Inalação , Resistência das Vias Respiratórias/efeitos dos fármacos , Resistência das Vias Respiratórias/fisiologia , Animais , Broncoconstritores/administração & dosagem , Broncoconstritores/farmacologia , Relação Dose-Resposta a Droga , Feminino , Imobilização/efeitos adversos , Cloreto de Metacolina/administração & dosagem , Cloreto de Metacolina/farmacologia , Camundongos , Camundongos Endogâmicos BALB C , Pletismografia Total/instrumentação , Pletismografia Total/métodos , Reprodutibilidade dos Testes , Restrição Física , Especificidade da Espécie , Organismos Livres de Patógenos Específicos
SELEÇÃO DE REFERÊNCIAS