Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Res Cardiol ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38806821

RESUMO

BACKGROUND: Immune checkpoint inhibitors (ICIs) can induce cardiovascular toxicities. OBJECTIVES: To prospectively assess the incidence of major cardiovascular events (MACE) on ICIs in solid cancer patients: myocarditis, pericarditis, acute coronary syndrome, heart failure, high-degree conduction abnormalities or sustained ventricular arrhythmias, or cardiovascular death at 6 weeks (early MACE), including asymptomatic clinical changes by an independent adjudication committee using current recommended diagnostic criteria. The secondary objective was the incidence of the above-mentioned events adding atrial fibrillation (AF) at 6 months (late MACE). RESULTS: Participants underwent pre-ICIs and repeated multimodality cardiac imaging (echocardiogram, cardiac magnetic resonance (CMR)), serum biomarkers (ultrasensitive troponin I), and rhythm surveillance (ambulatory ECG monitoring) at 6 weeks and 6 months. Forty-nine patients (38 (77.6%) male; mean age 64.3 (SD 11.0) years old) were included (June 2020-December 2021). Early MACE were observed in 9 (18.4%) patients at mean 40.1 (SD 5.9) days, with heart failure (HF) in 5 (10.2%), ventricular arrhythmias, or new conduction disorders in 4 (8.2%) patients. History of AF (HR 4.49 (CI 1.11-18.14), P = 0.035) predicted early MACE. At 6 months follow-up, 18 MACE were observed in 15/49 (31%) patients, with 6 (12.2%) HF events, 5 (10.2%) significant ventricular arrhythmias, or conduction disorders, and 4 (8.2%) AF. There was a significant decline in LVEF (P < 0.001) in patients with no MACE (P = 0.003) or HF (P = 0.0028). Higher creatinine at inclusion (HR 0.99 [0.98-1.00], P = 0.006) predicted HF on multivariate analysis. There were no significant T1 or T2 mapping changes in our study cohort on repeated CMR. CONCLUSIONS: Cardiotoxicity on ICIs is more frequent than previously described when using a thorough detection strategy, consisting mainly in HF and asymptomatic rhythm disorders.

2.
Eur Radiol ; 33(8): 5455-5464, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36905468

RESUMO

OBJECTIVES: Pulmonary regurgitation (PR) is common in adult congenital heart disease (ACHD). 2D phase contrast MRI is the reference method for the quantification of PR and helps in the decision of pulmonary valve replacement (PVR). 4D flow MRI can be an alternative method to estimate PR but more validation is still needed. Our purpose was to compare 2D and 4D flow in PR quantification using the degree of right ventricular remodeling after PVR as the reference standard. METHODS: In 30 adult patients with a pulmonary valve disease recruited between 2015 and 2018, PR was assessed using both 2D and 4D flow. Based on the clinical standard of care, 22 underwent PVR. The pre PVR estimate of PR was compared using the post-operative decrease in right ventricle end-diastolic volume on follow-up exam as reference. RESULTS: In the overall cohort, regurgitant volume (Rvol) and regurgitant fraction (RF) of PR measured by 2D and 4D flow were well correlated but with moderate agreement in the overall cohort (r = 0.90, mean diff. -14 ± 12.5 mL; and r = 0.72, mean diff. -15 ± 13%; all p < 0.0001). Correlations between Rvol estimates and right ventricle end-diastolic volume decrease after PVR was higher with 4D flow (r = 0.80, p < 0.0001) than with 2D flow (r = 0.72, p < 0.0001). CONCLUSIONS: In ACHD, PR quantification from 4D flow better predicts post-PVR right ventricle remodeling than that from 2D flow. Further studies are needed to evaluate the added value of this 4D flow quantification for guiding replacement decision. KEY POINTS: • Using 4D flow MRI allows a better quantification of pulmonary regurgitation in adult congenital heart disease than 2D flow when taking right ventricle remodeling after pulmonary valve replacement as a reference. • A plane positioned perpendicular to the ejected flow volume as allowed by 4D flow provides better results to estimate pulmonary regurgitation.


Assuntos
Cardiopatias Congênitas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Humanos , Adulto , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Seguimentos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Remodelação Ventricular , Imageamento por Ressonância Magnética , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Função Ventricular Direita
3.
J Digit Imaging ; 35(3): 594-604, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35233722

RESUMO

This study details application of deep learning for automatic segmentation of the ascending and descending aorta from 2D phase-contrast cine magnetic resonance imaging for automatic aortic analysis on the large MESA cohort with assessment on an external cohort of thoracic aortic aneurysm (TAA) patients. This study includes images and corresponding analysis of the ascending and descending aorta at the pulmonary artery bifurcation from the MESA study. Train, validation, and internal test sets consisted of 1123 studies (24,282 images), 374 studies (8067 images), and 375 studies (8069 images), respectively. The external test set of TAAs consisted of 37 studies (3224 images). CNN performance was evaluated utilizing a dice coefficient and concordance correlation coefficients (CCC) of geometric parameters. Dice coefficients were as high as 97.55% (CI: 97.47-97.62%) and 93.56% (CI: 84.63-96.68%) on the internal and external test of TAAs, respectively. CCC for maximum and minimum and ascending aortic area were 0.969 and 0.950, respectively, on the internal test set and 0.997 and 0.995, respectively, for the external test. The absolute differences between manual and deep learning segmentations for ascending and descending aortic distensibility were 0.0194 × 10-4 ± 9.67 × 10-4 and 0.002 ± 0.001 mmHg-1, respectively, on the internal test set and 0.44 × 10-4 ± 20.4 × 10-4 and 0.002 ± 0.001 mmHg-1, respectively, on the external test set. We successfully developed a U-Net-based aortic segmentation and analysis algorithm in both MESA and in external cases of TAA.


Assuntos
Aterosclerose , Aprendizado Profundo , Algoritmos , Aorta/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética
4.
J Magn Reson Imaging ; 56(5): 1416-1426, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35258133

RESUMO

BACKGROUND: Heart involvement is frequent although often clinically silent in systemic sclerosis (SSc) patients. Early identification of cardiac involvement can be improved by noninvasive methods such as MRI, in addition to transthoracic echocardiography (TTE). PURPOSE: To assess the ability of phase-contrast (PC)-MRI to detect subclinical left (LV) and right (RV) ventricular diastolic dysfunction in SSc patients. STUDY TYPE: Prospective. POPULATION: Thirty-five consecutive SSc patients (49 ± 14 years) and 35 sex- and age-matched healthy controls (48.6 ± 13.5 years) who underwent TTE and MRI in the same week. FIELD STRENGTH/SEQUENCE: 5 T/PC-MRI using a breath-hold velocity-encoded gradient echo sequence. ASSESSMENT: LV TTE (E/E') and LV and RV PC-MRI indices of diastolic function (LV early and late transmitral [EM , EfM , AM , AfM ] and RV transtricuspid [ET , EfT , AT , AfT ] peak filling flow velocities and flow rates, as well as LV [ E M ' ] and RV [ E T ' ] peak longitudinal myocardial velocities during diastole) were measured. STATISTICAL TESTS: Two-tailed t-test, Wilcoxon test, or Fischer test for comparison of variables between SSc and healthy control groups; sensitivity, specificity, receiver-operating-characteristic (ROC) area under the curve (AUC) to assess discriminative ability of variables. A P-value <0.05 was considered statistically significant. RESULTS: TTE LV E/E' and MRI EM / E M ' and ET / E T ' were significantly higher in SSc patients than in controls (8.27 ± 1.25 vs. 6.70 ± 1.66; 9.43 ± 2.7 vs. 6.51 ± 1.50; 6.51 [4.70-10.40] vs. 4.13 [3.22-5.75], respectively) and separated SSc patients and healthy controls with good sensitivity (68%, 71%, and 80%), specificity (85%, 94%, and 62%), and AUC (0.787, 0.807, and 0.765). LV EfM was significantly higher in SSc patients than in controls (347.1 ± 113.7 vs. 284.7 ± 94.6) as RVAfT (277 [231-355] vs. 220 [154-253] mL/sec) with impaired relaxation pattern (EfT /AfT , 0.95 [0.87-1.21] vs. 1.12 [0.93-1.47]). DATA CONCLUSION: MRI was able to detect LV and RV diastolic dysfunction in SSc patients with good accuracy in the absence of LV systolic dysfunction at echocardiography. Use of MRI can allow to better assess the early impact of myocardial fibrosis related to SSc. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Escleroderma Sistêmico , Disfunção Ventricular Esquerda , Disfunção Ventricular , Adulto , Diástole , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Prospectivos , Escleroderma Sistêmico/complicações , Escleroderma Sistêmico/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda
5.
Int J Cardiol ; 326: 206-212, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33259874

RESUMO

BACKGROUND: We aimed to provide a comprehensive aortic stiffness description using magnetic resonance imaging (MRI) in patients with ascending thoracic aorta aneurysm and tricuspid (TAV-ATAA) or bicuspid (BAV) aortic valve. METHODS: This case-control study included 18 TAV-ATAA and 19 BAV patients, with no aortic valve stenosis/severe regurgitation, who were 1:1 age-, gender- and central blood pressures (BP)-matched to healthy volunteers. Each underwent simultaneous aortic MRI and BP measurements. 3D anatomical MRI provided aortic diameters. Stiffness indices included: regional ascending (AA) and descending (DA) aorta pulse wave velocity (PWV) from 4D flow MRI; local AA and DA strain, distensibility and theoretical Bramwell-Hill (BH) model-based PWV, as well as regional arch PWV from 2D flow MRI. RESULTS: Patient groups had significantly higher maximal AA diameter (median[interquartile range], TAV-ATAA: 47.5[42.0-51.3]mm, BAV: 45.0[41.0-47.0]mm) than their respective controls (29.1[26.8-31.8] and 28.1[26.0-32.0]mm, p < 0.0001), while BP were similar (p ≥ 0.25). Stiffness indices were significantly associated with age (ρ ≥ 0.33), mean BP (arch PWV: ρ = 0.25, p = 0.05; DA distensibility: ρ = -0.30, p = 0.02) or AA diameter (arch PWV: ρ = 0.28, p = 0.03; DA PWV: ρ = 0.32, p = 0.009). None of them, however, was significantly different between TAV-ATAA or BAV patients and their matched controls. Finally, while direct PWV measures were significantly correlated to BH-PWV estimates in controls (ρ ≥ 0.40), associations were non-significant in TAV-ATAA and BAV groups (p ≥ 0.18). CONCLUSIONS: The overlap of MRI-derived aortic stiffness indices between patients with TAV or BAV aortopathy and matched controls highlights another heterogeneous feature of aortopathy, and suggests the urgent need for more sensitive indices which might help better discriminate such diseases.


Assuntos
Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Rigidez Vascular , Valva Aórtica/diagnóstico por imagem , Estudos de Casos e Controles , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Análise de Onda de Pulso
6.
Eur Radiol ; 31(6): 3909-3922, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33211147

RESUMO

Machine learning offers great opportunities to streamline and improve clinical care from the perspective of cardiac imagers, patients, and the industry and is a very active scientific research field. In light of these advances, the European Society of Cardiovascular Radiology (ESCR), a non-profit medical society dedicated to advancing cardiovascular radiology, has assembled a position statement regarding the use of machine learning (ML) in cardiovascular imaging. The purpose of this statement is to provide guidance on requirements for successful development and implementation of ML applications in cardiovascular imaging. In particular, recommendations on how to adequately design ML studies and how to report and interpret their results are provided. Finally, we identify opportunities and challenges ahead. While the focus of this position statement is ML development in cardiovascular imaging, most considerations are relevant to ML in radiology in general. KEY POINTS: • Development and clinical implementation of machine learning in cardiovascular imaging is a multidisciplinary pursuit. • Based on existing study quality standard frameworks such as SPIRIT and STARD, we propose a list of quality criteria for ML studies in radiology. • The cardiovascular imaging research community should strive for the compilation of multicenter datasets for the development, evaluation, and benchmarking of ML algorithms.


Assuntos
Aprendizado de Máquina , Radiologia , Algoritmos , Humanos , Radiografia , Sociedades Médicas
7.
Comput Methods Biomech Biomed Engin ; 23(14): 1060-1070, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32594759

RESUMO

Abdominal aortic aneurysm is a deadly disease that can be treated with different endovascular devices that will distinctly alter the aortic morphology. Computational methods can be used to understand the effect of anatomical changes on aortic hemodynamics. We propose a standardized method to assess morphological and hemodynamic changes of the abdominal aorta through the longitudinal axis of the vessel. Patient-specific CFD simulations were used to quantify these changes for two different endografts before and after surgery. Differences in cross-sectional area, blood pressure, peak blood velocity, wall shear stress, and retrograde blood flow were accurately evidenced with the proposed methodology.


Assuntos
Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Hemodinâmica , Pontos de Referência Anatômicos , Velocidade do Fluxo Sanguíneo , Prótese Vascular , Hemorreologia , Humanos , Modelos Cardiovasculares
9.
J Magn Reson Imaging ; 51(6): 1699-1705, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31794141

RESUMO

BACKGROUND: The main complication in adult patients with transposition of the great arteries (TGA) treated by an arterial switch operation (ASO) is neopulmonary outflow tract stenosis (NPOTS). However, pulmonary flow velocity measurements cannot always be performed with transthoracic echocardiography (TTE) due to complex anatomical features. 4D flow MRI allows detection, quantification, and location of the obstruction site along the NPOTS. PURPOSE AND HYPOTHESIS: To investigate the accuracy of 4D flow for the diagnosis of NPOTS in adults with TGA corrected by ASO. STUDY TYPE: Prospective. POPULATION: Thirty-three adult patients with TGA treated by ASO (19 men, mean age 25.5 years old). FIELD STRENGTH/SEQUENCE: Accelerated 4D flow research sequence at 3T. ASSESSMENT: Maximum NPOTS velocities on TTE and 4D flow MRI done the same day. STATISTICAL TESTS: Pearson correlation coefficient, paired t-test, and Bland-Altman analysis were used to investigate the relationship between TTE and MRI data. RESULTS: In 16 patients (48.5%), evaluation of NPOTS anatomy was not obtained by TTE, while it was always possible by 4D flow. Peak flow velocity (PV) measurements in Doppler and 4D flow were highly correlated (r = 0.78; P < 0.001). PV >350 cm.s-1 was detected in only one patient (3%) by TTE vs. five patients (15%) by 4D flow. Moreover, a high correlation was found between PV and the right ventricle (RV) mass index to body surface area when using 4D flow (r = 0.63; P < 0.001). The location of NPOTS was determined in all patients using 4D flow and concerned the main pulmonary artery in 42%. DATA CONCLUSION: Compared to TTE, 4D flow MRI provides better sensitivity to detect and locate NPOTS in patients with TGA treated by ASO. 4D flow PV measurements in NPOTS were well correlated with TTE PV and RV mass. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:1699-1705.


Assuntos
Transposição das Grandes Artérias , Transposição dos Grandes Vasos , Adulto , Transposição das Grandes Artérias/efeitos adversos , Artérias , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia
11.
Physiol Meas ; 38(11): 1953-1967, 2017 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-28968226

RESUMO

Pulse waveform analyses have become established components of cardiovascular research. Recently several methods have been proposed as tools to measure aortic pulse wave velocity (aPWV). The carotid-femoral pulse wave velocity (cf-PWV), the current clinical gold standard method for the noninvasive assessment of aPWV, uses the carotid-to-femoral pulse transit time difference (cf-PTT) and an estimated path length to derive cf-PWV. OBJECTIVE: The heart-ankle PWV (ha-PWV), brachial-ankle PWV (ba-PWV) and finger-toe (ft-PWV) are also methods presuming to approximate aPWV based on time delays between physiological cardiovascular signals at two locations (~heart-ankle PTT, ha-PTT; ~brachial-ankle PTT, ba-PTT; ~finger-toe PTT, ft-PTT) and a path length typically derived from the subject's height. To test the validity of these methods, we used a detailed 1D arterial network model (143 arterial segments) including the foot and hand circulation. APPROACH: The arterial tree dimensions and properties were taken from the literature and completed with data from patient scans. We calculated PTTs with all the methods mentioned above. The calculated PTTs were compared with the aortic PTT (aPTT), which is considered as the absolute reference method in this study. MAIN RESULTS: The correlation between methods and aPTT was good and significant, cf-PTT (R 2 = 0.97; P < 0.001; mean difference 5 ± 2 ms), ha-PTT (R 2 = 0.96; P < 0.001; 150 ± 23 ms), ba-PTT (R 2 = 0.96; P < 0.001; 70 ± 13 ms) and ft-PTT (R 2 = 0.95; P < 0.001; 14 ± 10 ms). Consequently, good correlation was also observed for the PWV values derived with the tested methods, but absolute values differed because of the different path lengths used. SIGNIFICANCE: In conclusion, our computer model-based analyses demonstrate that for PWV methods based on peripheral signals, pulse transit time differences closely correlate with the aortic transit time, supporting the use of these methods in clinical practice.


Assuntos
Aorta/fisiologia , Análise de Onda de Pulso/métodos , Rigidez Vascular , Aorta/anatomia & histologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Modelos Biológicos
12.
Hypertension ; 70(3): 652-658, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28716989

RESUMO

Fibromuscular dysplasia (FMD) commonly affects the renal and cervical arteries but has been described to affect other vascular beds as well. The prevalence of and clinical characteristics associated with multisite FMD (string-of-beds or focal stenoses affecting at least 2 vascular beds) are not known. In the prospective ARCADIA registry (Assessment of Renal and Cervical Artery Dysplasia), symptomatic patients with renal artery (RA) FMD underwent tomographic- or magnetic resonance-angiography from the aortic arch to the intracranial arteries and those with cervical FMD from the diaphragm to the pelvis. Of 469 patients (84.0% women), 225 (48.0%) had multisite FMD. In addition, 86 of 244 patients with single-site disease had dissections or aneurisms affecting other vascular beds, totaling 311 patients (66.3%) with lesions in >1 vascular bed. Among patients with a cerebrovascular presentation, the prevalence of RA lesions was higher in patients with than in those without hypertension (odds ratio, 3.4; 95% confidence interval, 1.99-6.15). Among patients with a renal presentation, the prevalence of cervical lesions was higher in patients with bilateral than in those with unilateral RA lesions (odds ratio, 1.9; 95% confidence interval, 0.99-3.57). In conclusion, FMD is a systemic arterial disease. At least 2 vascular beds were affected by dysplastic stenoses in 48.0% of cases and by dysplastic stenoses, aneurysms, and dissections in 66.1% of cases. RA imaging should be proposed to hypertensive patients with a cerebrovascular presentation. Cervical artery imaging should be considered in patients with a renal presentation and bilateral RA lesions. CLINICAL TRIAL REGISTRATION: URL: www.Clinicaltrials.gov. Unique identifier: NCT02884141.


Assuntos
Aneurisma , Dissecção Aórtica , Estenose das Carótidas , Displasia Fibromuscular , Hipertensão , Obstrução da Artéria Renal , Adulto , Idoso , Aneurisma/diagnóstico , Aneurisma/etiologia , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/etiologia , Bélgica/epidemiologia , Determinação da Pressão Arterial/métodos , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/epidemiologia , Angiografia por Tomografia Computadorizada/métodos , Feminino , Displasia Fibromuscular/complicações , Displasia Fibromuscular/diagnóstico , Displasia Fibromuscular/epidemiologia , Displasia Fibromuscular/fisiopatologia , França/epidemiologia , Humanos , Hipertensão/diagnóstico , Hipertensão/etiologia , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Prevalência , Sistema de Registros , Artéria Renal/diagnóstico por imagem , Artéria Renal/patologia , Obstrução da Artéria Renal/complicações , Obstrução da Artéria Renal/diagnóstico , Obstrução da Artéria Renal/epidemiologia , Índice de Gravidade de Doença
14.
J Magn Reson Imaging ; 42(2): 379-89, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25630749

RESUMO

BACKGROUND: Left atrium (LA) volumes and function are predictors of cardiovascular events. Because LA function cannot be assessed from cardiovascular magnetic resonance imaging (MRI) using the well-established left ventricular tagging techniques, we hypothesized that adequate feature tracking (FT) applied to conventional cine MRI data could characterize LA function accurately. METHODS: We studied 10 young (28 ± 7 years) and 10 elderly (64 ± 6 years) healthy subjects, as well as 20 patients with moderate to severe aortic valve stenosis (AVS; 73 ± 15 years, effective aortic valve area: 0.67 ± 0.36 cm(2) ). MRI cine two-, three-, and four-chamber views were analyzed using a newly proposed FT method based on spatial correlation and endocardial detection resulting in: regional and global longitudinal strain and strain rate, radial motion fraction and relative velocity for the three LA motion phases including reservoir, conduit, and LA contraction. RESULTS: FT reliability was indicated by a good overlap between tracking results and manual LA endocardial borders, the low error for comparison against theoretical strains introduced in a synthetic phantom and the good inter-observer reproducibility (coefficient of variation < 15%). While all LA functional parameters were significantly impaired in AVS patients (p < 0.04), subclinical age-related variations induced a decreasing trend on all LA parameters but were significant only for radial conduit function parameters (p < 0.03). Finally, LA functional parameters characterized LA alteration in AVS with higher sensitivity than conventional LA volumetric parameters. CONCLUSIONS: Left atrial FT is feasible on MRI cine images and its addition to conventional analysis tools might enhance the diagnosis value of MRI in many heart diseases.


Assuntos
Algoritmos , Estenose da Valva Aórtica/patologia , Átrios do Coração/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Med Eng Phys ; 37(1): 100-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25500196

RESUMO

Simultaneous pressure and volume measurements enable the extraction of valuable parameters for left ventricle function assessment. Cardiac MR has proven to be the most accurate method for volume estimation. Nonetheless, measuring pressure simultaneously during MRI acquisitions remains a challenge given the magnetic nature of the widely used pressure transducers. In this study we show the feasibility of simultaneous in vivo pressure-volume acquisitions with MRI using optical pressure sensors. Pressure-volume loops were calculated while inducing three inotropic states in a sheep and functional indices were extracted, using single beat loops, to characterize systolic and diastolic performance. Functional indices evolved as expected in response to positive inotropic stimuli. The end-systolic elastance, representing the contractility index, the diastolic myocardium compliance, and the cardiac work efficiency all increased when inducing inotropic state enhancement. The association of MRI and optical pressure sensors within the left ventricle successfully enabled pressure-volume loop analysis after having respective data simultaneously recorded during the experimentation without the need to move the animal between each inotropic state.


Assuntos
Pressão Sanguínea , Técnicas de Imagem Cardíaca/métodos , Ventrículos do Coração/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Imagem Óptica/métodos , Função Ventricular/fisiologia , Animais , Técnicas de Imagem Cardíaca/instrumentação , Estudos de Viabilidade , Feminino , Contração Miocárdica/fisiologia , Imagem Óptica/instrumentação , Tamanho do Órgão , Pressão , Ovinos
17.
Eur Radiol ; 18(10): 2140-7, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18523773

RESUMO

A computer-assisted method is proposed to estimate transmural extent of myocardial infarction. In 40 patients with chronic myocardial infarction and 3 control subjects, late gadolinium enhancement images were acquired with magnetic resonance imaging. Segmental infarct transmural extent was visually assessed by two experts on a 5-point scale. A fuzzy c-means algorithm was applied on both the cavity and myocardium to estimate an enhancement index for 12 sub-regions of each segment. A threshold was defined on a training database (n=29) to establish the transmurality extent of each sub-segment and was applied to the validation database (n=14). Inter-observer reproducibility reached an absolute agreement (Aa) of 85% and a kappa value (kappa) of 0.83 when considering the whole training database; Aa decreased to 62% and kappa to 0.68 when excluding homogeneous segments. On the validation database, segments were subdivided into three angular sub-segments. Then, inter-observer visual reproducibility reached Aa of 93% and kappa of 0.92. Moreover, the absolute comparison of each expert with the computer-assisted method yielded Aa higher than 88% and kappa higher than 0.86. The computer-assisted method quantifies infarct transmurality without defining remote and infarcted regions, and the transmural extent is accurately characterized when dividing each segment into three angular sub-segments.


Assuntos
Algoritmos , Gadolínio DTPA , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico , Disfunção Ventricular Esquerda/diagnóstico , Meios de Contraste , Humanos , Infarto do Miocárdio/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA