Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 90(3): 1870-1880, 2018 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-29276835

RESUMO

For LC-MS-based targeted quantification of biotherapeutics and biomarkers in clinical and pharmaceutical environments, high sensitivity, high throughput, and excellent robustness are all essential but remain challenging. For example, though nano-LC-MS has been employed to enhance analytical sensitivity, it falls short because of its low loading capacity, poor throughput, and low operational robustness. Furthermore, high chemical noise in protein bioanalysis typically limits the sensitivity. Here we describe a novel trapping-micro-LC-MS (T-µLC-MS) strategy for targeted protein bioanalysis, which achieves high sensitivity with exceptional robustness and high throughput. A rapid, high-capacity trapping of biological samples is followed by µLC-MS analysis; dynamic sample trapping and cleanup are performed using pH, column chemistry, and fluid mechanics separate from the µLC-MS analysis, enabling orthogonality, which contributes to the reduction of chemical noise and thus results in improved sensitivity. Typically, the selective-trapping and -delivery approach strategically removes >85% of the matrix peptides and detrimental components, markedly enhancing sensitivity, throughput, and operational robustness, and narrow-window-isolation selected-reaction monitoring further improves the signal-to-noise ratio. In addition, unique LC-hardware setups and flow approaches eliminate gradient shock and achieve effective peak compression, enabling highly sensitive analyses of plasma or tissue samples without band broadening. In this study, the quantification of 10 biotherapeutics and biomarkers in plasma and tissues was employed for method development. As observed, a significant sensitivity gain (up to 25-fold) compared with that of conventional LC-MS was achieved, although the average run time was only 8 min/sample. No appreciable peak deterioration or loss of sensitivity was observed after >1500 injections of tissue and plasma samples. The developed method enabled, for the first time, ultrasensitive LC-MS quantification of low levels of a monoclonal antibody and antigen in a tumor and cardiac troponin I in plasma after brief cardiac ischemia. This strategy is valuable when highly sensitive protein quantification in large sample sets is required, as is often the case in typical biomarker validation and pharmaceutical investigations of antibody therapeutics.


Assuntos
Cromatografia Líquida/instrumentação , Ensaios de Triagem em Larga Escala/instrumentação , Espectrometria de Massas/instrumentação , Peptídeos/análise , Proteínas/análise , Sequência de Aminoácidos , Animais , Anticorpos Monoclonais/análise , Biomarcadores/análise , Cromatografia Líquida/economia , Cromatografia Líquida/métodos , Desenho de Equipamento , Ensaios de Triagem em Larga Escala/economia , Ensaios de Triagem em Larga Escala/métodos , Humanos , Imunoglobulina G/análise , Limite de Detecção , Espectrometria de Massas/economia , Espectrometria de Massas/métodos , Camundongos , Ratos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA