Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Cardiol ; 82(5): 388-397, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37343930

RESUMO

BACKGROUND: Although remote monitoring (RM) after pacemaker implantation is common, its cost-effectiveness has not been fully investigated. Therefore, we assessed the cost-effectiveness of RM compared with conventional follow-up (CFU) in Japanese patients with pacemakers. METHODS: A Markov model was constructed to analyze costs and quality-adjusted life years after pacemaker implantation. The target population was Japanese patients implanted with a dual-chamber pacemaker for bradycardia. Transition probabilities (e.g. atrial fibrillation, stroke, and device trouble) were obtained from literature and expert sources. Additionally, stroke risk was determined according to anticoagulation and CHADS2 scores. We used a 10-year horizon with sensitivity analyses for significant variables. RESULTS: Compared to CFU, RM was more effective; however, it was also more expensive. When the range of the Japanese willingness-to-pay threshold was considered to be ¥5,000,000, RM was at least cost-neutral relative to the CFU in all elderly patients with pacemakers for bradycardia. The cost-effectiveness of RM relative to CFU could be higher for patients with high CHADS2 scores, especially in patients with a CHADS2 score ≥ 3. Scenario analyses changing the interval between visits to an in-office evaluation in the CFU also demonstrated the same conclusions. In particular, when the interval between office visits was 1 year for the CFU, the RM could be more cost-effective. CONCLUSIONS: This study demonstrated that RM can be a cost-effective option for Japanese patients, especially those with high CHADS2 scores and long-term intervals between office visits.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Acidente Vascular Cerebral , Humanos , Idoso , Bradicardia/etiologia , Bradicardia/terapia , Análise de Custo-Efetividade , Japão , Análise Custo-Benefício , Fibrilação Atrial/epidemiologia
2.
Jpn J Radiol ; 41(8): 843-853, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36811719

RESUMO

PURPOSE: To evaluate left atrial (LA) function in patients with hypertrophic cardiomyopathy (HCM) by LA strain assessment using cardiac computed tomography (CT-derived LA strain). MATERIALS AND METHODS: This was a retrospective study of 34 patients with HCM and 31 non-HCM patients who underwent cardiac computed tomography (CT) using retrospective electrocardiogram-gated mode. CT images were reconstructed every 5% (0-95%) of the RR intervals. CT-derived LA strain (reservoir [LASr], conduit [LASc], and booster pump strain [LASp]) were semi-automatically analyzed using a dedicated workstation. We also measured the left atrial volume index (LAVI) and left ventricular longitudinal strain (LVLS) for the left atrial and ventricular functional parameters to assess the relationship with CT-derived LA strain. RESULTS: CT-derived LA strain significantly correlated with LAVI: r = - 0.69, p < 0.001 for LASr; r = - 0.70, p < 0.001 for LASp; and r = - 0.35, p = 0.004 for LASc. CT-derived LA strain also significantly correlated with LVLS: r = - 0.62, p < 0.001 for LASr; r = - 0.67, p < 0.001 for LASc; and r = - 0.42, p = 0.013 for LASp. CT-derived LA strain in patients with HCM was significantly lower than that in non-HCM patients: LASr (20.8 ± 7.6 vs. 31.7 ± 6.1%, p < 0.001); LASc (7.9 ± 3.4 vs. 14.2 ± 5.3%, p < 0.001); and LASp (12.8 ± 5.7 vs. 17.6 ± 4.3%, p < 0.001). Additionally, CT-derived LA strain showed high reproducibility; inter-observer correlation coefficients were 0.94, 0.90, and 0.89 for LASr, LASc, and LASp, respectively. CONCLUSION: CT-derived LA strain is feasible for quantitative assessment of left atrial function in patients with HCM.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Humanos , Estudos Retrospectivos , Reprodutibilidade dos Testes , Átrios do Coração/diagnóstico por imagem , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Tomografia
3.
J Cardiol Cases ; 25(6): 389-391, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35685262

RESUMO

In extracardiac Fontan, an epicardial pacemaker implantation has many limitations, especially given that it is highly invasive and a high-risk procedure due to repeat thoracotomy. Herein we illustrate a case with the possibility of transvenous pacing in extracardiac Fontan being less invasive and lower risk transvenous dual-chamber pacemaker implantation by electrophysiological assessment. .

4.
Circ Rep ; 2(9): 507-516, 2020 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-33693276

RESUMO

Background: Although management of obstructive sleep apnea (OSA) has been recommended to improve outcomes of catheter ablation (CA) in patients with symptomatic atrial fibrillation (AF), the most cost-effective way of preprocedural OSA screening is undetermined. This study assessed the cost-effectiveness of OSA management before CA for symptomatic AF. Methods and Results: A Markov model was developed to assess the cost-effectiveness of 3 OSA detection strategies before CA: no screening; Type 3 portable monitor (PM)-guided screening; and polysomnography (PSG)-guided screening. The target population consisted of a hypothetical cohort of patients aged 65 years with symptomatic AF, with 50% prevalence of OSA. We used a 5-year horizon, with sensitivity analyses for significant variables and scenario analyses for lower and higher OSA prevalence (30% and 70%, respectively). In the base-case, both types of OSA screening were dominant (less costly and more effective) relative to no screening. Although PSG-guided management was more effective than PM-guided management, it was more costly and therefore did not show clear benefit. These findings were replicated in cohorts with lower and higher OSA risks. Conclusions: OSA screening before CA is cost-effective in patients with symptomatic AF, with PM screening being the most cost-effective. Physicians should consider OSA management using this simple tool in the decision making for treatment of symptomatic AF.

5.
Circ J ; 82(3): 815-823, 2018 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-29367514

RESUMO

BACKGROUND: Fractional flow reserve (FFR) is widely used for the assessment of myocardial ischemia. Intravascular ultrasound (IVUS) is an intracoronary imaging method that provides information about lumen and vessel morphology. Previous studies on the expanded use of IVUS to identify functional ischemia have noted an association between anatomy and physiology, but IVUS-derived minimum lumen area (MLA) has a weak-moderate correlation with myocardial ischemia compared with FFR. We developed a method to calculate FFR using IVUS-derived anatomical information for the assessment of myocardial ischemia. The aims of this study were to investigate the relationship between wire-based FFR and IVUS-derived FFR (IVUS-FFR) and to compare the usefulness of IVUS-FFR and IVUS-derived MLA for functional assessment.Methods and Results:We retrospectively analyzed 50 lesions in 48 patients with coronary stenosis who underwent IVUS and FFR simultaneously. IVUS-FFR was calculated using our original algorithm and fluid dynamics. Mean percent diameter stenosis determined on quantitative coronary angiography and on FFR was 56.4±10.7 and 0.69±0.08, respectively. IVUS-FFR had a stronger linear correlation with FFR (R=0.78, P<0.001; root mean square error, 0.057 FFR units) than with IVUS-derived MLA (R=0.43, P=0.002). CONCLUSIONS: IVUS-FFR may be a more valuable method to identify myocardial ischemia, compared with IVUS-derived MLA.


Assuntos
Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica/diagnóstico , Ultrassonografia de Intervenção/métodos , Idoso , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/patologia , Estudos Retrospectivos
6.
Am J Cardiol ; 120(10): 1772-1779, 2017 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-28864324

RESUMO

Fractional flow reserve (FFR) is widely used for the assessment of myocardial ischemia. Optical coherence tomography (OCT) provides accurate visualization of coronary artery morphology. The aim of this study was to investigate the relation between FFR and OCT-derived FFR. We retrospectively analyzed 31 lesions (25 left anterior descending arteries, 2 left circumflex arteries, and 4 right coronary arteries) in 31 patients with moderate-to-severe coronary stenosis, who underwent OCT and FFR measurements simultaneously. OCT-derived FFR was calculated by the original algorithm, which was calculated using the following equation based on fluid dynamics: ΔP = FV + SV2, where V is the flow velocity, F is the coefficient of pressure loss because of viscous friction (Poiseuille resistance), and S is the coefficient of local pressure loss because of abrupt enhancement (flow separation). Mean values of % diameter stenosis by quantitative coronary angiography and FFR were 55.2 ± 14.0% and 0.70 ± 0.14, respectively. OCT-derived FFR showed a stronger linear correlation with FFR measurements (r = 0.89, p <0.001; root mean square error = 0.062 FFR units) than quantitative coronary angiography % diameter stenosis (r = -0.65, p <0.001), OCT measurements of minimum lumen area (r = 0.68, p <0.001), and % area stenosis (r = -0.70, p <0.001). OCT-derived FFR has the potential to become an alternative method for the assessment of functional myocardial ischemia, and may elucidate the relation between coronary morphology and FFR.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
7.
Front Neurorobot ; 11: 67, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29311889

RESUMO

Humans divide perceived continuous information into segments to facilitate recognition. For example, humans can segment speech waves into recognizable morphemes. Analogously, continuous motions are segmented into recognizable unit actions. People can divide continuous information into segments without using explicit segment points. This capacity for unsupervised segmentation is also useful for robots, because it enables them to flexibly learn languages, gestures, and actions. In this paper, we propose a Gaussian process-hidden semi-Markov model (GP-HSMM) that can divide continuous time series data into segments in an unsupervised manner. Our proposed method consists of a generative model based on the hidden semi-Markov model (HSMM), the emission distributions of which are Gaussian processes (GPs). Continuous time series data is generated by connecting segments generated by the GP. Segmentation can be achieved by using forward filtering-backward sampling to estimate the model's parameters, including the lengths and classes of the segments. In an experiment using the CMU motion capture dataset, we tested GP-HSMM with motion capture data containing simple exercise motions; the results of this experiment showed that the proposed GP-HSMM was comparable with other methods. We also conducted an experiment using karate motion capture data, which is more complex than exercise motion capture data; in this experiment, the segmentation accuracy of GP-HSMM was 0.92, which outperformed other methods.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA