Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Transfus Clin Biol ; 29(2): 129-133, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34974187

RESUMO

INTRODUCTION: Acute coronary syndrome is a manifestation of coronary artery disease caused by decreased blood flow to the heart musculature resulting in ischaemia and infarction of the heart. The Lewis (Le) blood group system comprise mainly Lewis a & b antigens which are secreted in plasma and are expressed on red cells, platelets and endothelium. This study assesses the risk of multivessel disease in acute coronary patients with lewis negative (a- b-) phenotype. MATERIALS AND METHODS: The study included 183 patients diagnosed with acute coronary syndrome and who underwent coronary angiography to detect stenosis of the coronary vessels. The severity of the disease was classified based upon the number of vessels stenosed and their blood sample was phenotyped for Lewis antigens. The patients' risk factors, GRACE score and management were included for the study and multivariate logistic regression was carried out for analysis. RESULTS: The prevalence of Lewis (a- b-) was 27.4% and there was a significant association with multivessel disease (P<0.05). However, there was no association of lewis (a- b-) with any of the risk factors causing coronary disease. The adjusted odds ratio of triple vessel disease in lewis (a- b-) was 2.6, female gender was 0.6 and patients with diabetes mellitus was 3.1, respectively. The GRACE score showed a significant association with ABO blood group (P<0.05) but not with lewis (a- b-). DISCUSSION: Lewis negative patients are more likely to develop triple vessel disease compared to other lewis blood groups. This warrants further studies to investigate the link between lewis system and atherothrombosis.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Síndrome Coronariana Aguda/etiologia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/etiologia , Feminino , Humanos , Fenótipo , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença
2.
Catheter Cardiovasc Interv ; 80(6): 978-86, 2012 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-22566347

RESUMO

BACKGROUND: The triple lumen Inoue balloon is routinely used for balloon mitral valvotomy (BMV) in India. Its major limitation is the high cost. The double lumen Accura balloon is less expensive, making it an attractive alternative in the developing countries. The study was meant to assess the safety, efficacy and midterm results of Accura balloon with respect to the Inoue balloon. PATIENTS AND METHODS: 816 consecutive patients, who underwent elective BMV in this Institute from 1997 to 2003, were included in the study. The data of 487 patients who underwent BMV with Accura balloon was compared with 329 patients who underwent BMV with Inoue balloon. The clinical, echocardiographic, and hemodynamic data of these patients were analyzed retrospectively to assess the safety and efficacy of Accura balloon with respect to the Inoue balloon. RESULTS: Immediate procedural success (93.9% in Inoue group and 91.6% in Accura group p. NS) and complications (6.6% in Inoue group and 5.6% in Accura group p. NS) were comparable between the study groups. The two study population had similar restenosis rate and events at 1 year after BMV. Both balloons could be reused multiple times without compromising on the safety and effectiveness. Accura balloons were less costly than Inoue balloon. The reusability with Accura was slightly more and found to be more cost-effective. CONCLUSIONS: Both Accura and Inoue balloon mitral valvotomy balloons are effective in providing relief from hemodynamically significant mitral stenosis in terms of gain in valve area and reduction in trans mitral gradient. Both groups have similar procedural success and complication rates, restenosis, and follow-up events at 1 year. Both balloons could be reused multiple times and Accura balloon is found to be more cost effective.


Assuntos
Valvuloplastia com Balão/instrumentação , Cateteres Cardíacos , Estenose da Valva Mitral/terapia , Valva Mitral , Adulto , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/economia , Cateteres Cardíacos/economia , Distribuição de Qui-Quadrado , Redução de Custos , Ecocardiografia Doppler , Desenho de Equipamento , Reutilização de Equipamento , Feminino , Hemodinâmica , Custos Hospitalares , Humanos , Índia , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/economia , Estenose da Valva Mitral/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA