Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiol Case Rep ; 12(1): 179-184, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28228906

RESUMO

A 58-year-old man was diagnosed with advanced hepatocellular carcinoma with portal vein tumor thrombosis (PVTT). The tumors were multiple and existed in both lobes. Drug-eluting beads transcatheter arterial chemoembolization (DEB-TACE) was performed for the tumors in the left lobe. Embosphere and Hepasphere were selected for embolization of the arterioportal shunt, followed by loaded epirubicin infusion into the left hepatic artery. Computed tomography showed reduction of PVTT. However, liver failure progressed, and the patient died 67 days after DEB-TACE. Autopsy showed that the beads reached the tumor thrombosis in the portal vein. The prognosis of hepatocellular carcinoma with PVTT is poor. Although there are no established treatments for unresectable PVTT, DEB-TACE might be a useful option for such cases.

2.
Hepatol Res ; 47(12): 1252-1259, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28044427

RESUMO

AIM: Assessing disease progression in patients with primary biliary cholangitis (PBC) is necessary in order to evaluate therapeutic effectiveness. Therefore, the aims of this study were to evaluate both the diagnostic accuracy of both real-time tissue elastography (RTE) and vibration-controlled transient elastography (VCTE), and the usefulness of hepatic and splenic elasticity as predictive markers for the progression of symptomatic PBC. METHODS: The study participants were 44 patients with PBC. We assessed hepatic and splenic elasticity using RTE and VCTE and measured serum markers related to fibrosis and hepatic and splenic blood flow using Doppler ultrasonography. We then compared RTE and VCTE for diagnostic accuracy. Patients with asymptomatic PBC were followed every 1-3 months. RESULTS: Both RTE and VCTE performed well and had superior diagnostic accuracy compared with biochemical markers. The areas under the receiver operating characteristic curve for RTE and VCTE were 0.92 and 0.92, 0.95 and 0.91, and 0.97 and 0.91 for F ≥ 2, F ≥ 3, and F = 4, respectively. During follow-up, nine patients (25.0%) developed liver-related symptoms. Multivariate analysis revealed that splenic elasticity assessed using RTE was a significant independent factor for the development of liver-related symptoms (odds ratio, 2.19; P = 0.024). CONCLUSIONS: Real-time tissue elastography offered better diagnostic accuracy for severe fibrosis and cholangitis than VCTE. Splenic elasticity determined using RTE is a useful parameter for evaluating liver-related symptoms and an effective predictive marker of disease progression in patients with asymptomatic PBC.

3.
J Med Ultrason (2001) ; 43(2): 185-91, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27033864

RESUMO

PURPOSE: The purpose of this study was to assess the accuracy and efficacy of a needle-tracking system in phantom and clinical studies using bipolar electrodes. METHODS: To observe the tip of the electrode, a needle-tracking system with a volume navigation system was used. In the phantom study, the electrode was inserted at various angles and the error was verified. In the clinical study, 21 nodules close to extrahepatic organs or major vessels were enrolled between May and October 2014. After puncturing with the needle-tracking system, computed tomography (CT) was performed. The distances between the electrode tip and extrahepatic organs or major vessels were measured on both B-mode ultrasound (US) and CT. By comparing these distances, the accuracy of this system was evaluated. RESULTS: In the phantom study, the deviation between the tip of the electrode and the virtual tip of the electrode was analyzed. The median values were within 2 mm at each puncture angle. In the clinical study, the difference between B-mode US and CT was less (mean value 1.17 ± 1.76 mm; range 0-3.5 mm). CONCLUSION: The needle-tracking system is an accurate and useful system for bipolar radiofrequency ablation.


Assuntos
Técnicas de Ablação/métodos , Carcinoma Hepatocelular/cirurgia , Eletrodos , Neoplasias Hepáticas/cirurgia , Terapia por Radiofrequência , Cirurgia Assistida por Computador/métodos , Ultrassonografia/métodos , Técnicas de Ablação/instrumentação , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Agulhas , Imagens de Fantasmas , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA