1.
EuroIntervention ; 19(11): e891-e902, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37960875

RESUMO

BACKGROUND: Even with intracoronary imaging-guided stent optimisation, suboptimal haemodynamic outcomes post-percutaneous coronary intervention (PCI) can be related to residual lesions in non-stented segments. Preprocedural assessment of pathophysiological coronary artery disease (CAD) patterns could help predict the physiological response to PCI. AIMS: The aim of this study was to assess the relationship between preprocedural pathophysiological haemodynamic patterns and intracoronary imaging findings, as well as their association with physiological outcomes immediately post-PCI. METHODS: Data from 206 patients with chronic coronary syndrome enrolled in the ASET-JAPAN study were analysed. Pathophysiological CAD patterns were characterised using Murray law-based quantitative flow ratio (µQFR)-derived indices acquired from pre-PCI angiograms. The diffuseness of CAD was defined by the pullback pressure gradient (PPG) index. Intracoronary imaging in stented segments after stent optimisation was also analysed. RESULTS: In the multivariable analysis, diffuse disease - defined by the pre-PCI µQFR-PPG index - was an independent factor for predicting a post-PCI µQFR <0.91 (per 0.1 decrease of PPG index, odds ratio 1.57, 95% confidence interval: 1.07-2.34; p=0.022), whereas the stent expansion index (EI) was not associated with a suboptimal post-PCI µQFR. Among vessels with an EI ≥80% and post-PCI µQFR <0.91, 84.0% of those vessels had a diffuse pattern preprocedure. There was no significant difference in EI between vessels with diffuse disease and those with focal disease. The average plaque burden in the stented segment was significantly larger in vessels with a preprocedural diffuse CAD pattern. CONCLUSIONS: A physiological diffuse pattern preprocedure was an independent factor in predicting unfavourable immediate haemodynamic outcomes post-PCI, even after stent optimisation using intracoronary imaging. Preprocedural assessment of CAD patterns could identify patients who are likely to exhibit superior immediate haemodynamic outcomes following PCI.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Vasos Coronários/patologia , Resultado do Tratamento , Hemodinâmica , Valor Preditivo dos Testes
4.
Eur Heart J Cardiovasc Imaging ; 19(1): 92-100, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28200140

RESUMO

Aims: Coronary lesions precursors of acute events remain elusive, since they undergo continuous changes and their temporal changes are not very well-characterized. In natural history studies, optical frequency domain imaging (OFDI) has been used only to assess fibroatheromas as a 2D structure and sometimes in a single frame fashion. We aim at describing the serial volumetric modifications of the fibrous cap (FC) of the fibroatheromas as determined by OFDI over a 6-month follow-up period. Methods and results: In 49 patients, OFDI investigation was performed following treatment of culprit lesion and at 6-month follow-up in patients with ST-segment elevation myocardial infarction (STEMI). A fully automatic volumetric quantification of FC was done in all lipid-containing frames of non-culprit lesions in the infarct related artery. These lesions were matched at baseline and 6-month follow-up. A total of 58 non-culprit lipid rich lesions (34 TCFAs and 24 thick-cap fibroatheroma [ThCFA]) were found in 34 patients at baseline. Overall, there was a FC volume decrease of 1.57 (Inter-quartile Range [IQR] -4.13 to 0.54) mm3 at 6-months. 27% of the lesions changed their phenotype over time (TCFA or ThCFA). TCFAs that became ThCFAs at follow-up had smaller mean and maximal FC as compared with lesions that remained TCFAs (P = 0.01 for both). Conclusions: Non-culprit fibroatheromas located in the infarct related artery of patients with STEMI had a volumetric reduction of the FC after 6-month follow-up. Quantitative FC assessment was able to differentiate high-risk lesions that became ThCFAs. There was a considerable change of plaque phenotype (TCFAs or ThCFAs) over time.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Trombectomia/métodos , Tomografia de Coerência Óptica/métodos , Idoso , Terapia Combinada , Doença da Artéria Coronariana/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Placa Aterosclerótica/cirurgia , Estudos Prospectivos , Medição de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
5.
Cardiovasc Interv Ther ; 33(1): 11-22, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28766253

RESUMO

Vascular reparative therapy has become a reality with bioresorbable scaffolds (BRSs). To assess acute and long-term performance of the device, multimodality imaging would be essential. Radiopacity of metal hinders the imaging assessment, whereas radiolucent polymeric scaffolds allow for a precise imaging assessment with either invasive or non-invasive modality at baseline and at follow-up, which is one of the advantages of polymeric BRSs. Recent large trials evaluating clinical results of the first-generation BRS technology raised concerns about the safety and efficacy of these devices, namely, scaffold thrombosis. Intensive research with multimodality imaging in the field is being conducted to have in-depth understanding of the issues, which will facilitate the improvement of implantation techniques and the development of the next-generation BRSs. The current review focuses on the clinical application of the imaging modalities to assess the short- and long-term performance of the Absorb BVS.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Alicerces Teciduais , Doença da Artéria Coronariana/fisiopatologia , Stents Farmacológicos , Everolimo/administração & dosagem , Regeneração Tecidual Guiada , Humanos , Imagem Multimodal , Intervenção Coronária Percutânea , Poliésteres/administração & dosagem , Desenho de Prótese , Cicatrização/fisiologia
6.
JACC Cardiovasc Interv ; 9(12): 1216-1227, 2016 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-27339838

RESUMO

OBJECTIVES: The study compared, by intravascular ultrasound (IVUS), acute gain (AG) at the site of the pre-procedural minimal lumen area (MLA) achieved by either the Absorb (Abbott Vascular, Santa Clara, California) scaffold or the Xience stent and identified the factors contributing to the acute performance of these devices. BACKGROUND: It is warranted that the acute performance of Absorb matches that of metallic stents; however, concern exists about acute expansion and lumen gain with the use of Absorb. METHODS: Of a total of 501 patients (546 lesions) in the ABSORB II (ABSORB II Randomized Controlled Trial) randomized trial, 445 patients with 480 lesions were investigated by IVUS pre- and post-procedure. Comparison of MLA pre- and post-procedure was performed at the MLA site by matching pre- and post-procedural IVUS pullbacks. RESULTS: Lower AG on IVUS (lowest tertile) occurred more frequently in the Absorb arm than in the Xience arm (3.46 mm(2) vs. 4.27 mm(2), respectively; p < 0.001; risk ratio: 3.04; 95% confidence interval: 1.94 to 4.76). The plaque morphology at the MLA cross-section was not independently associated with IVUS acute gain. The main difference in AG in MLD by angiography was observed at the time of device implantation (Xience vs. Absorb, Δ+1.50 mm vs. Δ+1.23 mm, respectively), whereas the gain from post-dilation was similar between the 2 arms (Δ+0.16 mm vs. Δ+0.16 mm) when patients underwent post-dilation, although expected balloon diameter was smaller in the Absorb arm than in the Xience arm (p = 0.003) during post-dilation. CONCLUSIONS: At the site of the pre-procedural MLA, the increase of the lumen post-procedure was smaller in the Absorb-arm than in the Xience arm. To achieve equivalent AG to Xience, the implantation of Absorb may require more aggressive strategies at implantation, pre- and post-dilation than the technique used in the ABSORB II trial. (ABSORB II Randomized Controlled Trial [ABSORB II]; NCT01425281).


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença das Coronárias/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/administração & dosagem , Metais , Stents , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Everolimo/efeitos adversos , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 86(3): E140-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25914327

RESUMO

BACKGROUND: Three-dimensional (3D) quantitative coronary angiography (QCA) provides more accurate measurements by minimizing inherent limitations of two-dimensional (2D) QCA. The aim of this study was to compare the measurements between 2D and 3D QCA analyses in bifurcation lesions. METHODS AND RESULTS: A total of 114 cases with non-left main bifurcation lesions in the TRYTON pivotal IDE Coronary Bifurcation Trial (ClinicalTrials.gov: NCT01258972) were analyzed using a validated bifurcation QCA software (CAAS 5.10, Pie Medical Imaging, Maastricht, the Netherlands). All cases were analyzed in matched projections between pre- and post-procedure. The 2D analysis was performed using one of two angiographic images used for 3D reconstruction showing a larger distal bifurcation angle. In the treated segments (stent and balloon), there were no differences in minimal luminal diameter (MLD) between 2D and 3D, while diameter stenosis (DS) was significantly higher in 2D compared to 3D both pre-procedure and post-procedure (53.9% for 2D vs. 52.1% for 3D pre-procedure, P < 0.01; 23.2% for 2D vs. 20.9% for 3D post-procedure, P = 0.01). In the sub-segment level analysis, lengths of proximal main branch, distal main branch, and side branch were consistently shorter in 2D compared to 3D both pre-procedure and post-procedure. Using 3D QCA, the anatomic location of the smallest MLD or the highest DS was relocated to a different bifurcation sub-segment in a considerable proportion of the patients compared to when 2D-QCA was used (kappa values: 0.50 for MLD, 0.55 for DS). CONCLUSIONS: Our data showed differences in addressing anatomical severity and location of coronary bifurcation lesions between in vivo 2D and 3D QCA analyses. More studies are needed to investigate potential clinical benefits in using 3D approach over 2D QCA for the assessment of bifurcation lesions.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Humanos , Imageamento Tridimensional , Software , Resultado do Tratamento
8.
EuroIntervention ; 11(4): 407-15, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24974809

RESUMO

AIMS: To develop a methodology that permits accurate 3-dimensional (3D) reconstruction from FD-OCT and angiographic data enabling reliable evaluation of the ESS distribution, and to compare the FD-OCT-derived models against the established models based on angiography/IVUS. METHODS AND RESULTS: Fifteen patients (17 coronary arteries) who underwent angiography, FD-OCT and IVUS examination during the same procedure were studied. The FD-OCT and IVUS lumen borders were placed onto the 3D luminal centreline derived from angiographic data. Three-dimensional geometry algorithms and anatomical landmarks were used to estimate the orientation of the borders appropriately. ESS was calculated using computational fluid dynamics. In 188 corresponding consecutive 3-mm segments, FD-OCT- and IVUS-derived models were highly correlated for lumen area (r=0.96) and local ESS (r=0.89) measurements. FD-OCT-based 3D reconstructions had a high diagnostic accuracy for detecting regions exposed to proatherogenic low ESS identified on the IVUS-based 3D models, considered as the gold standard (receiver operator characteristic area under the curve: 94.9%). CONCLUSIONS: FD-OCT-based 3D coronary reconstruction provides anatomically correct models and permits reliable ESS computation. ESS assessment in combination with the superior definition of plaque characteristics by FD-OCT is expected to provide valuable insights into the effect of the haemodynamic environment on the development and destabilisation of high-risk plaques.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Vasos Coronários , Endotélio Vascular , Imageamento Tridimensional , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Idoso , Algoritmos , Pontos de Referência Anatômicos , Área Sob a Curva , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Endotélio Vascular/diagnóstico por imagem , Endotélio Vascular/patologia , Endotélio Vascular/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Placa Aterosclerótica , Valor Preditivo dos Testes , Curva ROC , Sistema de Registros , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Estresse Mecânico
9.
JACC Cardiovasc Interv ; 7(12): 1400-11, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25523532

RESUMO

OBJECTIVES: This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND: Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS: The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS: Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS: Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Stents Farmacológicos , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/diagnóstico , Everolimo , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
10.
EuroIntervention ; 10(5): 574-83, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24988003

RESUMO

AIMS: To develop a simplified approach of virtual functional assessment of coronary stenosis from routine angiographic data and test it against fractional flow reserve using a pressure wire (wire-FFR). METHODS AND RESULTS: Three-dimensional quantitative coronary angiography (3D-QCA) was performed in 139 vessels (120 patients) with intermediate lesions assessed by wire-FFR (reference standard: ≤0.80). The 3D-QCA models were processed with computational fluid dynamics (CFD) to calculate the lesion-specific pressure gradient (ΔP) and construct the ΔP-flow curve, from which the virtual functional assessment index (vFAI) was derived. The discriminatory power of vFAI for ischaemia- producing lesions was high (area under the receiver operator characteristic curve [AUC]: 92% [95% CI: 86-96%]). Diagnostic accuracy, sensitivity and specificity for the optimal vFAI cut-point (≤0.82) were 88%, 90% and 86%, respectively. Virtual-FAI demonstrated superior discrimination against 3D-QCA-derived % area stenosis (AUC: 78% [95% CI: 70- 84%]; p<0.0001 compared to vFAI). There was a close correlation (r=0.78, p<0.0001) and agreement of vFAI compared to wire-FFR (mean difference: -0.0039±0.085, p=0.59). CONCLUSIONS: We developed a fast and simple CFD-powered virtual haemodynamic assessment model using only routine angiography and without requiring any invasive physiology measurements/hyperaemia induction. Virtual-FAI showed a high diagnostic performance and incremental value to QCA for predicting wire-FFR; this "less invasive" approach could have important implications for patient management and cost.


Assuntos
Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Modelos Cardiovasculares , Idoso , Simulação por Computador , Estenose Coronária/fisiopatologia , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS