Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 35(4): 859-868, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32535849

RESUMO

Integrating spontaneous breathing into mechanical ventilation (MV) can speed up liberation from it and reduce its invasiveness. On the other hand, inadequate and asynchronous spontaneous breathing has the potential to aggravate lung injury. During use of airway-pressure-release-ventilation (APRV), the assisted breaths are difficult to measure. We developed an algorithm to differentiate the breaths in a setting of lung injury in spontaneously breathing ewes. We hypothesized that differentiation of breaths into spontaneous, mechanical and assisted is feasible using a specially developed for this purpose algorithm. Ventilation parameters were recorded by software that integrated ventilator output variables. The flow signal, measured by the EVITA® XL (Lübeck, Germany), was measured every 2 ms by a custom Java-based computerized algorithm (Breath-Sep). By integrating the flow signal, tidal volume (VT) of each breath was calculated. By using the flow curve the algorithm separated the different breaths and numbered them for each time point. Breaths were separated into mechanical, assisted and spontaneous. Bland Altman analysis was used to compare parameters. Comparing the values calculated by Breath-Sep with the data from the EVITA® using Bland-Altman analyses showed a mean bias of - 2.85% and 95% limits of agreement from - 25.76 to 20.06% for MVtotal. For respiratory rate (RR) RRset a bias of 0.84% with a SD of 1.21% and 95% limits of agreement from - 1.53 to 3.21% were found. In the cluster analysis of the 25th highest breaths of each group RRtotal was higher using the EVITA®. In the mechanical subgroup the values for RRspont and MVspont the EVITA® showed higher values compared to Breath-Sep. We developed a computerized method for respiratory flow-curve based differentiation of breathing cycle components during mechanical ventilation with superimposed spontaneous breathing. Further studies in humans and optimizing of this technique is necessary to allow for real-time use at the bedside.


Assuntos
Respiração Artificial , Respiração , Animais , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Humanos , Pulmão , Ovinos , Volume de Ventilação Pulmonar
2.
Burns ; 40(7): 1308-15, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25112807

RESUMO

PURPOSE: Compare virtual bronchoscopy (VB) to fiberoptic bronchoscopy (FOB) for scoring smoke inhalation injury (SII). METHODS: Swine underwent computerized tomography (CT) with VB and FOB before (0) and 24 and 48 h after SII. VB and FOB images were scored by 5 providers off line. RESULTS: FOB and VB scores increased over time (p<0.001) with FOB scoring higher than VB at 0 (0.30±0.79 vs. 0.03±0.17), 24 h (4.21±1.68 vs. 2.47±1.50), and 48h (4.55±1.83 vs. 1.94±1.29). FOB and VB showed association with PaO2-to-FiO2 ratios (PFR) with areas under receiver operating characteristic curves (ROC): for PFR≤300, VB 0.830, FOB 0.863; for PFR≤200, VB 0.794, FOB 0.825; for PFR≤100, VB 0.747, FOB 0.777 (all p<0.001). FOB showed 80.3% specificity, 77% sensitivity, 88.8% negative-predictive value (NPV), and 62.3% positive-predictive value (PPV) for PFR≤300 and VB showed 67.2% specificity, 85.5% sensitivity, 91.3% NPV, and 53.4% PPV. CONCLUSIONS: VB provided similar injury severity scores to FOB, correlated with PFR, and reliably detected airway narrowing. VB performed during admission CT may be a useful screening tool specifically to demonstrate airway narrowing induced by SII.


Assuntos
Broncoscopia , Pulmão/diagnóstico por imagem , Lesão por Inalação de Fumaça/diagnóstico , Tomografia Computadorizada por Raios X , Animais , Feminino , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Lesão por Inalação de Fumaça/diagnóstico por imagem , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA