1.
J Magn Reson Imaging ; 59(5): 1582-1592, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37485870

RESUMO

BACKGROUND: Pancreatic ductal adenocarcinoma (PDAC) stromal viscoelasticity can be measured using MR elastography (MRE). Bowel preparation regimens could affect MRE quality and knowledge on repeatability is crucial for clinical implementation. PURPOSE: To assess effects of four bowel preparation regimens on MRE quality and to evaluate repeatability and differentiate patients from healthy controls. STUDY TYPE: Prospective. POPULATION: 15 controls (41 ± 16 years; 47% female), 16 PDAC patients (one excluded, 66 ± 12 years; 40% female) with 15 age-/sex-matched controls (65 ± 11 years; 40% female). Final sample size was 25 controls and 15 PDAC. FIELD STRENGTH/SEQUENCE: 3-T, spin-echo echo-planar-imaging, turbo spin-echo, and fast field echo gradient-echo. ASSESSMENT: Four different regimens were used: fasting; scopolaminebutyl; drinking 0.5 L water; combination of 0.5 L water and scopolaminebutyl. MRE signal-to-noise ratio (SNR) was compared between all regimens. MRE repeatability (test-retest) and differences in shear wave speed (SWS) and phase angle (ϕ) were assessed in PDAC and controls. Regions-of-interest were defined for tumor, nontumorous (n = 8) tissue in PDAC, and whole pancreas in controls. Two radiologists delineated tumors twice for evaluation of intraobserver and interobserver variability. STATISTICAL TESTS: Repeated measures analysis of variance, coefficients of variation (CoVs), Bland-Altman analysis, (un)paired t-test, Mann-Whitney U-test, and Wilcoxon signed-rank test. P-value<0.05 was considered statistically significant. RESULTS: Preparation regimens did not significantly influence MRE-SNR. Therefore, the least burdensome preparation (fasting only) was continued. CoVs for tumor SWS were: intrasession (12.8%) and intersession (21.7%), and intraobserver (7.9%) and interobserver (10.3%) comparisons. For controls, CoVs were intrasession (4.6%) and intersession (6.4%). Average SWS for tumor, nontumor, and healthy tissue were: 1.74 ± 0.58, 1.38 ± 0.27, and 1.18 ± 0.16 m/sec (ϕ: 1.02 ± 0.17, 0.91 ± 0.07, and 0.85 ± 0.08 rad), respectively. Significant differences were found between all groups, except for ϕ between healthy-nontumor (P = 0.094). DATA CONCLUSION: The proposed bowel preparation regimens may not influence MRE quality. MRE may be able to differentiate between healthy tissue-tumor and tumor-nontumor. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Técnicas de Imagem por Elasticidade , Neoplasias Pancreáticas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Imageamento por Ressonância Magnética/métodos , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Reprodutibilidade dos Testes , Água
2.
Int J Cardiovasc Imaging ; 38(11): 2385-2394, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36434328

RESUMO

To longitudinally assess left ventricle (LV) global longitudinal strain (GLS) and hemodynamic forces during the early stages of cardiac dysfunction in a mouse model of heart failure with preserved ejection fraction (HFpEF). Cardiac MRI measurements were performed in control mice (n = 6), and db/db mice (n = 7), whereby animals were scanned four times between the age of 11-15 weeks. After the first scan, the db/db animals received a doxycycline intervention to accelerate progression of HFpEF. Systolic function was evaluated based on a series of prospectively ECG-triggered short-axis CINE images acquired from base to apex. Cardiac GLS and hemodynamic forces values were evaluated based on high frame rate retrospectively gated 2-, 3-, and 4-chamber long-axis CINE images. Ejection fraction (EF) was not different between control and db/db animals, despite that cardiac output, as well as end systolic and end diastolic volume were significantly higher in control animals. Whereas GLS parameters were not significantly different between groups, hemodynamic force root mean square (RMS) values, as well as average hemodynamic forces and the ratio between hemodynamic forces in the inferolateral-anteroseptal and apical-basal direction were lower in db/db mice compared to controls. More importantly, hemodynamic forces parameters showed a significant interaction effect between time and group. Our results indicated that hemodynamic forces parameters were the only functional outcome measure that showed distinct temporal differences between groups. As such, changes in hemodynamic forces reflect early alterations in cardiac function which can be of added value in (pre)clinical research on HFpEF.


Assuntos
Insuficiência Cardíaca , Camundongos , Animais , Insuficiência Cardíaca/diagnóstico por imagem , Volume Sistólico , Estudos Retrospectivos , Valor Preditivo dos Testes , Hemodinâmica , Modelos Animais de Doenças
3.
Haematologica ; 107(11): 2708-2719, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35548868

RESUMO

Silent cerebral infarcts (SCI) are common in patients with sickle cell disease (SCD) and are thought to be caused by a mismatch between oxygen delivery and consumption. Functional cerebrovascular shunting is defined as reduced oxygen offloading due to the rapid transit of blood through the capillaries caused by increased flow and has been suggested as a potential mechanism underlying reduced oxygenation and SCI. We investigated the venous arterial spin labeling signal (VS) in the sagittal sinus as a proxy biomarker of cerebral functional shunting, and its association with hemodynamic imaging and hematological laboratory parameters. We included 28 children and 38 adults with SCD, and ten healthy racematched adult controls. VS, cerebral blood flow (CBF), velocity in the brain feeding arteries, oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2) were measured before and after acetazolamide administration. VS was higher in patients with SCD compared to controls (P<0.01) and was increased after acetazolamide administration in all groups (P<0.01). VS was primarily predicted by CBF (P<0.01), but CBF-corrected VS was also associated with decreased CMRO2 (P<0.01). Additionally, higher disease severity defined by low hemoglobin and increased hemolysis was associated with higher CBF-corrected VS. Finally, CMRO2 was negatively correlated with fetal hemoglobin, and positively correlated with lactate dehydrogenase, which could be explained by changes in oxygen affinity. These findings provide evidence for cerebral functional shunting and encourage future studies investigating the potential link to aberrant capillary exchange in SCD.


Assuntos
Anemia Falciforme , Imageamento por Ressonância Magnética , Adulto , Criança , Humanos , Imageamento por Ressonância Magnética/métodos , Acetazolamida , Encéfalo/irrigação sanguínea , Encéfalo/metabolismo , Oxigênio/metabolismo , Infarto Cerebral , Consumo de Oxigênio/fisiologia
4.
PLoS One ; 17(1): e0261777, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35085267

RESUMO

BACKGROUND: The purpose of this study was to develop a DTI-based method to quantitatively assess fiber angles and changes therein in leg muscles in order to facilitate longitudinal studies on muscle fiber architectural adaptations in healthy subjects. METHODS: The upper legs of five volunteers were scanned twice on the same day. The right lower legs of five volunteers were scanned twice with the ankle in three positions, i.e. -15° dorsiflexion, 0° neutral position, and 30° plantarflexion. The MRI protocols consisted of a noise scan, a 3-point mDixon scan and a DTI scan. Fiber-angle color maps were generated for four muscles in the upper legs and two muscles in the lower leg. Voxel-wise fiber angles (θ) were calculated from the angle between the principal eigenvector of the diffusion tensor and a reference line defined between the origo and insertion points of each muscle. Bland-Altman analysis, intraclass correlation coefficient (ICC), coefficient of variation (CV%), minimal detectable change (MDC), standard error (SE) and Friedman test were used for assessing the feasibility of this method and in order to have an indication of the repeatability and the sensitivity. RESULTS: Bland-Altman analysis showed good repeatability (CV%<10 and 0.7≤ICC≤0.9) with exception of the Tibialis Anterior (TA) muscle in dorsiflexion position(CV%: 12.2) and the Semitendinosus (ST) muscle (left leg) (CV%: 11.4). The best repeatability metrics were found for the SOL muscle in neutral position (CV%: 2.6). Changes in average θ in TA and SOL with ankle positions were observed in accordance with expected agonist and antagonist functions of both muscles. For example, for the anterior left compartment the change in fiber angle Δθ with respect to the neutral position Δθ = -1.6° ± 0.8° and 2.2° ± 2.8° (p = 0.008), for dorsiflexion and plantarflexion, respectively. CONCLUSION: Our method facilitates fast inspection and quantification of muscle fiber angles in the lower and upper leg muscles in rest and detection of changes in lower-leg muscle fiber angles with varying ankle angles.


Assuntos
Tornozelo/diagnóstico por imagem , Imagem de Tensor de Difusão , Perna (Membro)/diagnóstico por imagem , Fibras Musculares Esqueléticas , Adulto , Feminino , Humanos , Masculino
5.
Front Bioeng Biotechnol ; 9: 725833, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34869250

RESUMO

Magnetic resonance imaging (MRI) can potentially be used for non-invasive screening of patients with stable angina pectoris to identify probable obstructive coronary artery disease. MRI-based coronary blood flow quantification has to date only been performed in a 2D fashion, limiting its clinical applicability. In this study, we propose a framework for coronary blood flow quantification using accelerated 4D flow MRI with respiratory motion correction and compressed sensing image reconstruction. We investigate its feasibility and repeatability in healthy subjects at rest. Fourteen healthy subjects received 8 times-accelerated 4D flow MRI covering the left coronary artery (LCA) with an isotropic spatial resolution of 1.0 mm3. Respiratory motion correction was performed based on 1) lung-liver navigator signal, 2) real-time monitoring of foot-head motion of the liver and LCA by a separate acquisition, and 3) rigid image registration to correct for anterior-posterior motion. Time-averaged diastolic LCA flow was determined, as well as time-averaged diastolic maximal velocity (VMAX) and diastolic peak velocity (VPEAK). 2D flow MRI scans of the LCA were acquired for reference. Scan-rescan repeatability and agreement between 4D flow MRI and 2D flow MRI were assessed in terms of concordance correlation coefficient (CCC) and coefficient of variation (CV). The protocol resulted in good visibility of the LCA in 11 out of 14 subjects (six female, five male, aged 28 ± 4 years). The other 3 subjects were excluded from analysis. Time-averaged diastolic LCA flow measured by 4D flow MRI was 1.30 ± 0.39 ml/s and demonstrated good scan-rescan repeatability (CCC/CV = 0.79/20.4%). Time-averaged diastolic VMAX (17.2 ± 3.0 cm/s) and diastolic VPEAK (24.4 ± 6.5 cm/s) demonstrated moderate repeatability (CCC/CV = 0.52/19.0% and 0.68/23.0%, respectively). 4D flow- and 2D flow-based diastolic LCA flow agreed well (CCC/CV = 0.75/20.1%). Agreement between 4D flow MRI and 2D flow MRI was moderate for both diastolic VMAX and VPEAK (CCC/CV = 0.68/20.3% and 0.53/27.0%, respectively). In conclusion, the proposed framework of accelerated 4D flow MRI equipped with respiratory motion correction and compressed sensing image reconstruction enables repeatable diastolic LCA flow quantification that agrees well with 2D flow MRI.

6.
J Magn Reson Imaging ; 54(6): 1937-1949, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33991378

RESUMO

BACKGROUND: Noninvasive diagnostic methods are urgently required in disease stratification and monitoring in nonalcoholic fatty liver disease (NAFLD). Multiparametric magnetic resonance imaging (MRI) is a promising technique to assess hepatic steatosis, inflammation, and fibrosis, potentially enabling noninvasive identification of individuals with active and advanced stages of NAFLD. PURPOSE: To examine the diagnostic performance of multiparametric MRI for the assessment of disease severity along the NAFLD disease spectrum with comparison to histological scores. STUDY TYPE: Prospective, cohort. POPULATION: Thirty-seven patients with NAFLD. FIELD STRENGTH/SEQUENCE: Multiparametric MRI at 3.0 T consisted of magnetic resonance (MR) spectroscopy (MRS) with multi-echo stimulated-echo acquisition mode, magnitude-based and three-point Dixon using a two-dimensional multi-echo gradient echo, MR elastography (MRE) using a generalized multishot gradient-recalled echo sequence and intravoxel incoherent motion (IVIM) using a multislice diffusion weighted single-shot echo-planar sequence. ASSESSMENT: Histological steatosis grades were compared to proton density fat fraction measured by MRS (PDFFMRS ), magnitude-based MRI (PDFFMRI-M ), and three-point Dixon (PDFFDixon ), as well as FibroScan® controlled attenuation parameter (CAP). Fibrosis and disease activity were compared to IVIM and MRE. FibroScan® liver stiffness measurements were compared to fibrosis levels. Diagnostic performance of all imaging parameters was determined for distinction between simple steatosis and nonalcoholic steatohepatitis (NASH). STATISTICAL TESTS: Spearman's rank test, Kruskal-Wallis test, Dunn's post-hoc test with Holm-Bonferroni P-value adjustment, receiver operating characteristic curve analysis. A P-value <0.05 was considered statistically significant. RESULTS: Histological steatosis grade correlated significantly with PDFFMRS (rs  = 0.66, P < 0.001), PDFFMRI-M (rs  = 0.68, P < 0.001), and PDFFDixon (rs  = 0.67, P < 0.001), whereas no correlation was found with CAP. MRE and IVIM diffusion and perfusion significantly correlated with disease activity (rs  = 0.55, P < 0.001, rs  = -0.40, P = 0.016, rs  = -0.37, P = 0.027, respectively) and fibrosis (rs  = 0.55, P < 0.001, rs  = -0.46, P = 0.0051; rs  = -0.53, P < 0.001, respectively). MRE and IVIM diffusion had the highest area-under-the-curve for distinction between simple steatosis and NASH (0.79 and 0.73, respectively). DATA CONCLUSION: Multiparametric MRI is a promising method for noninvasive, accurate, and sensitive distinction between simple hepatic steatosis and NASH, as well as for the assessment of steatosis and fibrosis severity. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: 2.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Biópsia , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Estudos Prospectivos
7.
Radiology ; 295(2): 373-380, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32154774

RESUMO

Background Diffusion-weighted imaging (DWI) can depict the inflamed synovial membrane in arthritis. Purpose To study the diagnostic accuracy of DWI for the detection of arthritis compared with the clinical reference standard and to compare DWI to contrast material-enhanced MRI for the detection of synovial inflammation. Materials and Methods In this institutional review board-approved prospective study, 45 participants with juvenile idiopathic arthritis (JIA) or suspected of having JIA (seven boys, 38 girls; median age, 14 years [interquartile range, 12-16 years]) were included between December 2015 and December 2018. Study participants underwent pre- and postcontrast 3.0-T MRI of the knee with an additional DWI sequence. For the clinical reference standard, a multidisciplinary team determined the presence or absence of arthritis on the basis of clinical, laboratory, and imaging findings (excluding DWI). Two data sets were scored by two radiologists blinded to all clinical data; data set 1 contained pre- and postcontrast sequences (contrast-enhanced MRI), and data set 2 contained precontrast and DWI sequences (DWI). Diagnostic accuracy was determined by comparing the scores of the DWI data set to those of the clinical reference standard. Second, DWI was compared with contrast-enhanced MRI regarding detection of synovial inflammation. Results Sensitivity for detection of arthritis for DWI was 93% (13 of the 14 participants with arthritis were correctly classified with DWI; 95% confidence interval [CI]: 64%, 100%) and specificity was 81% (25 of 31 participants without arthritis were correctly classified with DWI; 95% CI: 62%, 92%). Scores for synovial inflammation at DWI and contrast-enhanced MRI agreed in 37 of 45 participants (82%), resulting in a sensitivity of 92% (12 of 13 participants; 95% CI: 62%, 100%) and specificity of 78% (25 of 32 participants; 95% CI: 60%, 90%) with DWI when contrast-enhanced MRI was considered the reference standard. Conclusion Diffusion-weighted imaging (DWI) was accurate in detecting arthritis in pediatric participants with juvenile idiopathic arthritis (JIA) or suspected of having JIA and showed agreement with contrast-enhanced MRI. The results indicate that DWI could replace contrast-enhanced MRI for imaging of synovial inflammation in this patient group. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
Artrite Juvenil/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Osteoartrite do Joelho/diagnóstico por imagem , Adolescente , Criança , Meios de Contraste , Feminino , Humanos , Masculino , Estudos Prospectivos , Sensibilidade e Especificidade
8.
Neurogastroenterol Motil ; 32(2): e13747, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31828938

RESUMO

BACKGROUND: Continuously tagged MRI during free breathing can assess bowel motility at frequencies as low as the slow wave, motility pattern range. This study aimed to evaluate noninvasive gastrointestinal-tagged MRI for small bowel motility assessment and to observe the physiological response to a 300-kcal meal challenge in healthy, overnight-fasted volunteers. METHODS: After overnight fasting, 16 healthy subjects (7 women, mean age 25.5, range 19-37 years) underwent a free breathing, tagged MRI scan to capture small bowel motility. Each subject underwent a (a) baseline motility scan, (b) food challenge, (c) postchallenge scan, and (d) second postchallenge scan (after 20 minutes). Motility was quantified using a frequency analysis technique for measuring the spectral power of the strain, referred to as motility score. Motility score was assessed in 20 frequency intervals between 1 and 20 contractions per minute (cpm), and the data were analyzed with linear mixed-effect models. KEY RESULT: The stimulation protocol demonstrated an immediate, food-induced, motility response in the low-frequency range (2-10 cpm), which is consistent with the stomach and small bowel frequency range (3-12 cpm). CONCLUSIONS AND INFERENCES: This study shows that this MRI tagging technique is able to quantify the fasted-to-fed response to a 300-kcal meal challenge within the specific small bowel motility frequency range in healthy subjects. The food provocation MRI protocol provides a tool to explore the gut's response to a stimulus in specific motility frequency ranges in patients with gastrointestinal dysmotility and functional disorders.


Assuntos
Motilidade Gastrointestinal/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Diagnóstico por Imagem/métodos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Adulto Jovem
9.
J Neuromuscul Dis ; 6(1): 1-30, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30714967

RESUMO

Neuromuscular diseases are characterized by progressive muscle degeneration and muscle weakness resulting in functional disabilities. While each of these diseases is individually rare, they are common as a group, and a large majority lacks effective treatment with fully market approved drugs. Magnetic resonance imaging and spectroscopy techniques (MRI and MRS) are showing increasing promise as an outcome measure in clinical trials for these diseases. In 2013, the European Union funded the COST (co-operation in science and technology) action BM1304 called MYO-MRI (www.myo-mri.eu), with the overall aim to advance novel MRI and MRS techniques for both diagnosis and quantitative monitoring of neuromuscular diseases through sharing of expertise and data, joint development of protocols, opportunities for young researchers and creation of an online atlas of muscle MRI and MRS. In this report, the topics that were discussed in the framework of working group 3, which had the objective to: Explore new contrasts, new targets and new imaging techniques for NMD are described. The report is written by the scientists who attended the meetings and presented their data. An overview is given on the different contrasts that MRI can generate and their application, clinical needs and desired readouts, and emerging methods.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Músculos/diagnóstico por imagem , Doenças Neuromusculares/diagnóstico por imagem , Animais , Doenças do Cão/diagnóstico por imagem , Cães , União Europeia , Humanos , Doenças Neuromusculares/veterinária
10.
J Cardiovasc Magn Reson ; 20(1): 86, 2018 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-30567566

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) allows for non-invasive assessment of arterial stiffness by means of measuring pulse wave velocity (PWV). PWV can be calculated from the time shift between two time-resolved flow curves acquired at two locations within an arterial segment. These flow curves can be derived from two-dimensional CINE phase contrast CMR (2D CINE PC CMR). While CMR-derived PWV measurements have proven to be accurate for the aorta, this is more challenging for smaller arteries such as the carotids due to the need for both high spatial and temporal resolution. In this work, we present a novel method that combines retrospectively gated 2D CINE PC CMR, high temporal binning of data and compressed sensing (CS) reconstruction to accomplish a temporal resolution of 4 ms. This enables accurate flow measurements and assessment of PWV in regional carotid artery segments. METHODS: Retrospectively gated 2D CINE PC CMR data acquired in the carotid artery was binned into cardiac frames of 4 ms length, resulting in an incoherently undersampled ky-t-space with a mean undersampling factor of 5. The images were reconstructed by a non-linear CS reconstruction using total variation over time as a sparsifying transform. PWV values were calculated from flow curves by using foot-to-foot and cross-correlation methods. Our method was validated against ultrasound measurements in a flow phantom setup representing the carotid artery. Additionally, PWV values of two groups of 23 young (30 ± 3 years, 12 [52%] women) and 10 elderly (62 ± 10 years, 5 [50%] women) healthy subjects were compared using the Wilcoxon rank-sum test. RESULTS: Our proposed method produced very similar flow curves as those measured using ultrasound at 1 ms temporal resolution. Reliable PWV estimation proved possible for transit times down to 7.5 ms. Furthermore, significant differences in PWV values between healthy young and elderly subjects were found (4.7 ± 1.0 m/s and 7.9 ± 2.4 m/s, respectively; p < 0.001) in accordance with literature. CONCLUSIONS: Retrospectively gated 2D CINE PC CMR with CS allows for high spatiotemporal resolution flow measurements and accurate regional carotid artery PWV calculations. We foresee this technique will be valuable in protocols investigating early development of carotid atherosclerosis.


Assuntos
Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/diagnóstico por imagem , Compressão de Dados , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Rigidez Vascular , Adulto , Velocidade do Fluxo Sanguíneo , Técnicas de Imagem de Sincronização Cardíaca , Artérias Carótidas/fisiopatologia , Doenças das Artérias Carótidas/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Imagem Cinética por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Valor Preditivo dos Testes , Análise de Onda de Pulso , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Ultrassonografia
11.
NMR Biomed ; 29(12): 1813-1824, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27862471

RESUMO

In this study we investigated the changes in fiber length and diffusion parameters as a consequence of passive lengthening and stretching of the calf muscles. We hypothesized that changes in radial diffusivity (RD) are caused by changes in the muscle fiber cross sectional area (CSA) as a consequence of lengthening and shortening of the muscle. Diffusion Tensor MRI (DT-MRI) measurements were made twice in five healthy volunteers, with the foot in three different positions (30° plantarflexion, neutral position and 15° dorsiflexion). The muscles of the calf were manually segmented on co-registered high resolution anatomical scans, and maps of RD and axial diffusivity (AD) were reconstructed from the DT-MRI data. Fiber tractography was performed and mean fiber length was calculated for each muscle group. Significant negative correlations were found between the changes in RD and changes in fiber length in the dorsiflexed and plantarflexed positions, compared with the neutral foot position. Changes in AD did not correlate with changes in fiber length. Assuming a simple cylindrical model with constant volume for the muscle fiber, the changes in the muscle fiber CSA were calculated from the changes in fiber length. In line with our hypothesis, we observed a significant positive correlation of the CSA with the measured changes in RD. In conclusion, we showed that changes in diffusion coefficients induced by passive muscle stretching and lengthening can be explained by changes in muscle CSA, advancing the physiological interpretation of parameters derived from skeletal muscle DT-MRI.


Assuntos
Imagem de Tensor de Difusão/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fibras Musculares Esqueléticas/citologia , Fibras Musculares Esqueléticas/fisiologia , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Adulto , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Resistência à Tração/fisiologia
12.
Med Phys ; 43(10): 5603, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27782717

RESUMO

PURPOSE: Biliary stents may cause susceptibility artifacts, gradient-induced artifacts, and radio frequency (RF) induced artifacts on magnetic resonance images, which can hinder accurate target volume delineation in radiotherapy. In this study, the authors investigated and quantified the magnitude of these artifacts for stents of different materials. METHODS: Eight biliary stents made of nitinol, platinum-cored nitinol, stainless steel, or polyethylene from seven vendors, with different lengths (57-98 mm) and diameters (3.0-11.7 mm), were placed in a phantom. To quantify the susceptibility artifacts sequence-independently, ΔB0-maps and T2∗-maps were acquired at 1.5 and 3 T. To study the effect of the gradient-induced artifacts at 3 T, signal decay in images obtained with maximum readout gradient-induced artifacts was compared to signal decay in reference scans. To quantify the RF induced artifacts at 3 T, B1-maps were acquired. Finally, ΔB0-maps and T2∗-maps were acquired at 3 T of two pancreatic cancer patients who had received platinum-cored nitinol biliary stents. RESULTS: Outside the stent, susceptibility artifacts dominated the other artifacts. The stainless steel stent produced the largest susceptibility artifacts. The other stents caused decreased T2∗ up to 5.1 mm (1.5 T) and 8.5 mm (3 T) from the edge of the stent. For sequences with a higher bandwidth per voxel (1.5 T: BWvox > 275 Hz/voxel; 3 T: BWvox > 500 Hz/voxel), the B0-related susceptibility artifacts were negligible (<0.2 voxels). The polyethylene stent showed no artifacts. In vivo, the changes in B0 and T2∗ induced by the stent were larger than typical variations in B0 and T2∗ induced by anatomy when the stent was at an angle of 30° with the main magnetic field. CONCLUSIONS: Susceptibility artifacts were dominating over the other artifacts. The magnitudes of the susceptibility artifacts were determined sequence-independently. This method allows to include additional safety margins that ensure target irradiation.


Assuntos
Artefatos , Angiografia por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Stents , Cirurgia Assistida por Computador/métodos , Humanos , Ondas de Rádio
13.
PLoS One ; 11(9): e0163316, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27669568

RESUMO

INTRODUCTION: Wall shear stress (WSS) and oscillatory shear index (OSI) are associated with atherosclerotic disease. Both parameters are derived from blood velocities, which can be measured with phase-contrast MRI (PC-MRI). Limitations in spatiotemporal resolution of PC-MRI are known to affect these measurements. Our aim was to investigate the effect of spatiotemporal resolution using a carotid artery phantom. METHODS: A carotid artery phantom was connected to a flow set-up supplying pulsatile flow. MRI measurement planes were placed at the common carotid artery (CCA) and internal carotid artery (ICA). Two-dimensional PC-MRI measurements were performed with thirty different spatiotemporal resolution settings. The MRI flow measurement was validated with ultrasound probe measurements. Mean flow, peak flow, flow waveform, WSS and OSI were compared for these spatiotemporal resolutions using regression analysis. The slopes of the regression lines were reported in %/mm and %/100ms. The distribution of low and high WSS and OSI was compared between different spatiotemporal resolutions. RESULTS: The mean PC-MRI CCA flow (2.5±0.2mL/s) agreed with the ultrasound probe measurements (2.7±0.02mL/s). Mean flow (mL/s) depended only on spatial resolution (CCA:-13%/mm, ICA:-49%/mm). Peak flow (mL/s) depended on both spatial (CCA:-13%/mm, ICA:-17%/mm) and temporal resolution (CCA:-19%/100ms, ICA:-24%/100ms). Mean WSS (Pa) was in inverse relationship only with spatial resolution (CCA:-19%/mm, ICA:-33%/mm). OSI was dependent on spatial resolution for CCA (-26%/mm) and temporal resolution for ICA (-16%/100ms). The regions of low and high WSS and OSI matched for most of the spatiotemporal resolutions (CCA:30/30, ICA:28/30 cases for WSS; CCA:23/30, ICA:29/30 cases for OSI). CONCLUSION: We show that both mean flow and mean WSS are independent of temporal resolution. Peak flow and OSI are dependent on both spatial and temporal resolution. However, the magnitude of mean and peak flow, WSS and OSI, and the spatial distribution of OSI and WSS did not exhibit a strong dependency on spatiotemporal resolution.

14.
Thromb Haemost ; 115(3): 493-500, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26791734

RESUMO

Carotid atherosclerotic plaques are a major cause of ischaemic stroke. The biomechanical environment to which the arterial wall and plaque is subjected to plays an important role in the initiation, progression and rupture of carotid plaques. MRI is frequently used to characterize the morphology of a carotid plaque, but new developments in MRI enable more functional assessment of carotid plaques. In this review, MRI based biomechanical parameters are evaluated on their current status, clinical applicability, and future developments. Blood flow related biomechanical parameters, including endothelial wall shear stress and oscillatory shear index, have been shown to be related to plaque formation. Deriving these parameters directly from MRI flow measurements is feasible and has great potential for future carotid plaque development prediction. Blood pressure induced stresses in a plaque may exceed the tissue strength, potentially leading to plaque rupture. Multi-contrast MRI based stress calculations in combination with tissue strength assessment based on MRI inflammation imaging may provide a plaque stress-strength balance that can be used to assess the plaque rupture risk potential. Direct plaque strain analysis based on dynamic MRI is already able to identify local plaque displacement during the cardiac cycle. However, clinical evidence linking MRI strain to plaque vulnerability is still lacking. MRI based biomechanical parameters may lead to improved assessment of carotid plaque development and rupture risk. However, better MRI systems and faster sequences are required to improve the spatial and temporal resolution, as well as increase the image contrast and signal-to-noise ratio.


Assuntos
Artérias Carótidas/fisiopatologia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/fisiopatologia , Imageamento por Ressonância Magnética , Animais , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Humanos , Inflamação , Oscilometria , Resistência ao Cisalhamento , Razão Sinal-Ruído , Estresse Mecânico
15.
Magn Reson Imaging ; 34(2): 219-26, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26597833

RESUMO

PURPOSE: Liver diseases are a major global health concern often requiring invasive assessment by needle biopsy. (31)P magnetic resonance spectroscopic imaging (MRSI) allows non-invasive probing of important liver metabolites. Recently, the adiabatic multi-echo spectroscopic imaging sequence with spherical k-space sampling (AMESING) was introduced at 7T, enabling acquisition of T2 information. T2-weighed averaging of the multiple echoes improves signal-to-noise ratio (SNR). The purpose of our study was to implement AMESING MRSI of the liver at 3T and 7T, derive localized T2 information and compare T2-weighted average spectra in terms of SNR. METHODS: Ten male volunteers underwent 2D AMESING MRSI at 3T and 7T after a minimum four-hour fast. SNR was calculated for PC, PE, Pi, GPE, GPC and α-ATP using maximum peak amplitudes and the SD of the noise. Metabolite peak ratios were calculated after fitting in jMRUI. SNR values and peak ratios were compared with the Wilcoxon signed-rank test. RESULTS: For the first time liver metabolites' T2 values at 7T were measured: PE (55.6±3.5 ms), PC (51.2±2.3 ms), Pi (46.4±1.1 ms), GPE (44.0±0.8 ms), GPC (50.4±0.8 ms) and α-ATP (18.2±0.4 ms). SNR gain using T2-weighted averaging at 7T resulted in a 1.2× SNR gain. In conjunction with higher field strength and improved coil set-up T2-weighted averaging at 7T allowed a total 3.2× SNR gain compared to 3T FID-only. CONCLUSION: AMESING 2D MRSI of the liver at 7T provides T2 values that allow T2-weighted averaging of data from multiple echoes resulting in improved SNR.


Assuntos
Artefatos , Aumento da Imagem/métodos , Fígado/anatomia & histologia , Fígado/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Compostos de Fósforo/metabolismo , Adulto , Algoritmos , Biomarcadores/metabolismo , Humanos , Masculino , Isótopos de Fósforo/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Distribuição Tecidual
16.
J Magn Reson Imaging ; 39(1): 9-16, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23553805

RESUMO

PURPOSE: To evaluate continuously tagged 3 Tesla MRI for monitoring glucagon-induced bowel motility changes in healthy volunteers. MATERIALS AND METHODS: After standardized oral bowel preparation, 10 healthy volunteers underwent a free-breathing, continuously tagged three-dimensional (3D) dynamic fast-field-echo (FFE), at a 3.36 Hz sampling frequency. One milligram of glucagon was administered intravenously during data acquisition. Each dataset was divided into four temporal sets of 2 min (period 1 to 4). Taglines were tracked automatically using a scale spaced based algorithm. Assessment of global spectral resolution was performed for three frequency intervals: 0.008-0.300 Hz (motility), 0.300-0.400 Hz (breathing motion), and 0.400-0.533 Hz (higher order motion). Additional analyses were performed at fine spectral resolution in frequency bands of 0.033 Hz. Glucagon-induced motility changes were investigated by means of a motility index (spectral power normalized to the maximal spectral power per-volunteer), resulting in a range of 0 to 1 (no motion to maximal motion). Statistical comparison was done for period 1 and 4 (Wilcoxon-signed rank test). RESULTS: After glucagon administration, a significant decrease in the motility index was found for the low- (0.008-0.300 Hz) (P < 0.0001) and high-frequency interval (0.400-0.533 Hz) (P < 0.0001). Around breathing motion frequencies, no decrease in motility index was detected. CONCLUSION: Free-breathing, continuously tagged MR imaging is a noninvasive method for automated bowel motility assessment and allows for detection of drug-induced changes.


Assuntos
Motilidade Gastrointestinal/fisiologia , Imageamento por Ressonância Magnética , Movimento (Física) , Adulto , Algoritmos , Automação , Feminino , Glucagon/química , Voluntários Saudáveis , Humanos , Imageamento Tridimensional , Intestinos/patologia , Masculino , Estudos Prospectivos , Valores de Referência , Adulto Jovem
17.
J Magn Reson Imaging ; 36(2): 492-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22411355

RESUMO

PURPOSE: To investigate the feasibility of measuring motion in the abdomen using a continuously tagged magnetic resonance imaging sequence. MATERIALS AND METHODS: To assess (nonperiodic) motion in the abdomen, a nontriggered, continuously tagged transient field echo (TFE) sequence was implemented that acquires one complete 3D dataset per prepulse after a fixed delay. In postprocessing, a frequency analysis approach was developed for compact reviewing of the data and noise suppression. For proof of principle, a simulation was made and one free-breathing dynamic in vivo scan was acquired in a healthy volunteer. During the dynamic scan the volunteer received glucagon intravenously. RESULTS: The simulation showed that this frequency analysis enables the extraction of motion at low signal-to-noise ratio levels. Motion information was successfully gathered from the in vivo scan. The decline in bowel motion caused by the administration of glucagon could be quantitatively measured using the continuously tagged sequence. CONCLUSION: Continuously tagged imaging in the abdomen for the purpose of automated gathering of motion information is feasible and could aid the study of bowel motion.


Assuntos
Abdome/anatomia & histologia , Abdome/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Movimento/fisiologia , Reconhecimento Automatizado de Padrão/métodos , Adulto , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
18.
AJR Am J Roentgenol ; 196(6): W736-42, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21606262

RESUMO

OBJECTIVE: The purpose of this study was to assess, with histopathologic control, the use of open-system 1-T (1)H MR spectroscopy for the evaluation of hepatic steatosis in morbidly obese patients undergoing gastric bypass surgery. SUBJECTS AND METHODS: Patients underwent (1)H MR spectroscopy (MRS) for the assessment of steatosis before and 3 months after surgery. Liver biopsy was performed during surgery. Hepatic steatosis was expressed as the ratio of fat peak area to cumulative water and fat peak areas. Histopathologic percentage of steatosis was graded as none (0-5%), mild (5-33%), moderate (33-66%), or severe (> 66%). The accuracy of (1)H-MRS and Spearman correlation coefficient were calculated. Differences between groups were assessed with the Wilcoxon signed rank and Mann-Whitney tests. RESULTS: The study included 38 patients (median age, 45.5 years; median body mass index, 47.7). Before surgery, median steatosis measured with (1)H-MRS was 5.8%. The accuracy of (1)H-MRS was 89% (32/36), and the (1)H-MRS findings correlated with the histopathologic assessment of steatosis (r = 0.85, p < 0.001). With (1)H-MRS, no steatosis was discriminated from mild steatosis (p = 0.011), mild was discriminated from moderate steatosis (p < 0.001), and moderate was discriminated from severe steatosis (p = 0.021). Three months after surgery, steatosis had decreased to 3.1% (p < 0.001). The prevalence of hepatic steatosis measured with (1)H-MRS decreased from 53% to 32%. CONCLUSION: In the care of morbidly obese patients undergoing assessment of hepatic steatosis and changes in steatosis after gastric bypass surgery, (1)H-MRS with an open 1-T MRI system is feasible. Measurements of hepatic fat with (1)H-MRS are accurate and correlate with clinical and histopathologic results.


Assuntos
Fígado Gorduroso/patologia , Derivação Gástrica , Espectroscopia de Ressonância Magnética/métodos , Obesidade Mórbida/patologia , Obesidade Mórbida/cirurgia , Adulto , Biópsia , Índice de Massa Corporal , Fígado Gorduroso/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Resultado do Tratamento
19.
Radiology ; 256(1): 159-68, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20574093

RESUMO

PURPOSE: To compare the diagnostic performance of ultrasonography (US), computed tomography (CT), T1-weighted dual-echo magnetic resonance (MR) imaging, and point-resolved proton (hydrogen 1[(1)H]) MR spectroscopy in the assessment of hepatic steatosis in patients undergoing liver resection. MATERIALS AND METHODS: This prospective study was approved by the institutional review board, and patients gave written informed consent. US, CT, T1-weighted MR imaging, and (1)H MR spectroscopy were performed preoperatively in 46 patients. Imaging results were correlated (Spearman correlation coefficient) with histopathologic analysis of results of intraoperative liver biopsies. To assess differences between groups, one-way analysis of variance was used. Sensitivity and specificity were calculated for each imaging modality by using receiver operating characteristic curve analysis, with a histopathologic cut-off value of 5% macrovesicular steatosis. Differences in sensitivity and specificity were assessed by means of McNemar analysis. RESULTS: At histopathologic examination, 23 patients had no (0%-5%) macrovesicular steatosis, 11 had mild (5%-33%), nine had moderate (33%-66%), and three had severe (>66%). MR imaging and (1)H MR spectroscopic measurements of hepatic fat had stronger correlation with histopathologic steatosis assessment (r = 0.85, P < .001 and r = 0.86, P < .001, respectively) than did US (r = 0.66, P < .001) and CT (r = -0.55, P < .001). Only T1-weighted MR imaging and (1)H MR spectroscopy showed differences across steatosis grades: none versus mild (P = .001 for both), mild versus moderate (P < .001 for both), and moderate versus severe (P = .04 and .01, respectively). Sensitivity of US, CT, T1-weighted MR imaging, and (1)H MR spectroscopy was 65% (13 of 20), 74% (17 of 23), 90% (19 of 21), and 91% (21 of 23), respectively, and specificity was 77% (17 of 23), 70% (14 of 20), 91% (20 of 22), and 87% (20 of 23), respectively. CONCLUSION: In contrast to US and CT, T1-weighted MR imaging and (1)H MR spectroscopy strongly correlate with histopathologic steatosis assessment and are able to demonstrate differences across steatosis grades. T1-weighted dual-echo MR imaging and (1)H MR spectroscopy had the best diagnostic accuracy in depicting hepatic steatosis.


Assuntos
Fígado Gorduroso/diagnóstico , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Adulto , Idoso , Biópsia , Fígado Gorduroso/patologia , Feminino , Humanos , Hepatopatias/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade