Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Int J Cardiovasc Imaging ; 36(1): 91-100, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31414256

RESUMO

Transthoracic echocardiography (TTE) is the primary clinical imaging modality for the assessment of patients with isolated aortic regurgitation (AR) in whom TTE's linear left ventricular (LV) dimension is used to assess disease severity to guide aortic valve replacement (AVR), yet TTE is relatively limited with regards to its integrated semi-quantitative/qualitative approach. We therefore compared TTE and cardiovascular magnetic resonance (CMR) assessment of isolated AR and investigated each modality's ability to predict LV remodeling after AVR. AR severity grading by CMR and TTE were compared in 101 consecutive patients referred for CMR assessment of chronic AR. LV end-diastolic diameter and end-systolic diameter measurements by both modalities were compared. Twenty-four patients subsequently had isolated AVR. The pre-AVR estimates of regurgitation severity by CMR and TTE were correlated with favorable post-AVR LV remodeling. AR severity grade agreement between CMR and TTE was moderate (ρ = 0.317, P = 0.001). TTE underestimated CMR LV end-diastolic and LV end-systolic diameter by 6.6 mm (P < 0.001, CI 5.8-7.7) and 5.9 mm (P < 0.001, CI 4.1-7.6), respectively. The correlation of post-AVR LV remodeling with CMR AR grade (ρ = 0.578, P = 0.004) and AR volumes (R = 0.664, P < 0.001) was stronger in comparison to TTE (ρ = 0.511, P = 0.011; R = 0.318, P = 0.2). In chronic AR, CMR provides more prognostic relevant information than TTE in assessing AR severity. CMR should be considered in the management of chronic AR patients being considered for AVR.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler , Imagem Cinética por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Idoso , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Doença Crônica , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
2.
Magn Reson Med ; 81(5): 3192-3201, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30565296

RESUMO

PURPOSE: To develop a gadolinium-free cardiac MR technique that simultaneously exploits native T1 and magnetization transfer (MT) contrast for the imaging of myocardial infarction. METHODS: A novel hybrid T one and magnetization transfer (HYTOM) method was developed based on the modified look-locker inversion recovery (MOLLI) sequence, with a train of MT-prep pulses placed before the balanced SSFP (bSSFP) readout pulses. Numerical simulations, based on Bloch-McConnell equations, were performed to investigate the effects of MT induced by (1) the bSSFP readout pulses, and (2) the MT-prep pulses, on the measured, "apparent," native T1 values. The HYTOM method was then tested on 8 healthy adult subjects, 6 patients, and a swine with prior myocardial infarction (MI). The resulting imaging contrast between normal myocardium and infarcted tissues was compared with that of MOLLI. Late gadolinium enhancement (LGE) images were also obtained for infarct assessment in patients and swine. RESULTS: Numerical simulation and in vivo studies in healthy volunteers demonstrated that MT effects, resulting from on-resonance bSSFP excitation pulses and off-resonance MT-prep pulses, reduce the measured T1 in both MOLLI and HTYOM. In vivo studies in patients and swine showed that the HYTOM sequence can identify locations of MI, as seen on LGE. Furthermore, the HYTOM method yields higher myocardium-to-scar contrast than MOLLI (contrast-to-noise ratio: 7.33 ± 1.67 vs. 3.77 ± 0.66, P < 0.01). CONCLUSION: The proposed HYTOM method simultaneously exploits native T1 and MT contrast and significantly boosts the imaging contrast for myocardial infarction.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio/administração & dosagem , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Adulto , Idoso , Animais , Simulação por Computador , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Magnetismo , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Distribuição Normal , Estudos Prospectivos , Suínos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA