Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
2.
Med Phys ; 44(9): 4747-4757, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28657201

RESUMO

PURPOSE: Quantitative computed tomography (CT) measures are increasingly being developed and used to characterize lung disease. With recent advances in CT technologies, we sought to evaluate the quantitative accuracy of lung imaging at low- and ultralow-radiation doses with the use of iterative reconstruction (IR), tube current modulation (TCM), and spectral shaping. METHODS: We investigated the effect of five independent CT protocols reconstructed with IR on quantitative airway measures and global lung measures using an in vivo large animal model as a human subject surrogate. A control protocol was chosen (NIH-SPIROMICS + TCM) and five independent protocols investigating TCM, low- and ultralow-radiation dose, and spectral shaping. For all scans, quantitative global parenchymal measurements (mean, median and standard deviation of the parenchymal HU, along with measures of emphysema) and global airway measurements (number of segmented airways and pi10) were generated. In addition, selected individual airway measurements (minor and major inner diameter, wall thickness, inner and outer area, inner and outer perimeter, wall area fraction, and inner equivalent circle diameter) were evaluated. Comparisons were made between control and target protocols using difference and repeatability measures. RESULTS: Estimated CT volume dose index (CTDIvol) across all protocols ranged from 7.32 mGy to 0.32 mGy. Low- and ultralow-dose protocols required more manual editing and resolved fewer airway branches; yet, comparable pi10 whole lung measures were observed across all protocols. Similar trends in acquired parenchymal and airway measurements were observed across all protocols, with increased measurement differences using the ultralow-dose protocols. However, for small airways (1.9 ± 0.2 mm) and medium airways (5.7 ± 0.4 mm), the measurement differences across all protocols were comparable to the control protocol repeatability across breath holds. Diameters, wall thickness, wall area fraction, and equivalent diameter had smaller measurement differences than area and perimeter measurements. CONCLUSIONS: In conclusion, the use of IR with low- and ultralow-dose CT protocols with CT volume dose indices down to 0.32 mGy maintains selected quantitative parenchymal and airway measurements relevant to pulmonary disease characterization.


Assuntos
Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Humanos , Pulmão
3.
Invest Radiol ; 48(9): 629-37, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23571834

RESUMO

OBJECTIVE: Dual-energy x-ray computed tomography (DECT) offers visualization of the airways and quantitation of regional pulmonary ventilation using a single breath of inhaled xenon gas. In this study, we sought to optimize scanning protocols for DECT xenon gas ventilation imaging of the airways and lung parenchyma and to characterize the quantitative nature of the developed protocols through a series of test-object and animal studies. MATERIALS AND METHODS: The Institutional Animal Care and Use Committee approved all animal studies reported here. A range of xenon/oxygen gas mixtures (0%, 20%, 25%, 33%, 50%, 66%, 100%; balance oxygen) were scanned in syringes and balloon test-objects to optimize the delivered gas mixture for assessment of regional ventilation while allowing for the development of improved 3-material decomposition calibration parameters. In addition, to alleviate gravitational effects on xenon gas distribution, we replaced a portion of the oxygen in the xenon/oxygen gas mixture with helium and compared gas distributions in a rapid-prototyped human central-airway test-object. Additional syringe tests were performed to determine if the introduction of helium had any effect on xenon quantitation. Xenon gas mixtures were delivered to anesthetized swine to assess airway and lung parenchymal opacification while evaluating various DECT scan acquisition settings. RESULTS: Attenuation curves for xenon were obtained from the syringe test-objects and were used to develop improved 3-material decomposition parameters (Hounsfield unit enhancement per percentage xenon: within the chest phantom, 2.25 at 80 kVp, 1.7 at 100 kVp, and 0.76 at 140 kVp with tin filtration; in open air, 2.5 at 80 kVp, 1.95 at 100 kVp, and 0.81 at 140 kVp with tin filtration). The addition of helium improved the distribution of xenon gas to the gravitationally nondependent portion of the airway tree test-object, while not affecting the quantitation of xenon in the 3-material decomposition DECT. The mixture 40% Xe/40% He/20% O2 provided good signal-to-noise ratio (SNR), greater than the Rose criterion (SNR > 5), while avoiding gravitational effects of similar concentrations of xenon in a 60% O2 mixture. Compared with 100/140 Sn kVp, 80/140 Sn kVp (Sn = tin filtered) provided improved SNR in a swine with an equivalent thoracic transverse density to a human subject with a body mass index of 33 kg/m. Airways were brighter in the 80/140 Sn kVp scan (80/140 Sn, 31.6%; 100/140 Sn, 25.1%) with considerably lower noise (80/140 Sn, coefficient of variation of 0.140; 100/140 Sn, coefficient of variation of 0.216). CONCLUSION: To provide a truly quantitative measure of regional lung function with xenon-DECT, the basic protocols and parameter calibrations need to be better understood and quantified. It is critically important to understand the fundamentals of new techniques to allow for proper implementation and interpretation of their results before widespread usage. With the use of an in-house derived xenon calibration curve for 3-material decomposition rather than the scanner supplied calibration and a xenon/helium/oxygen mixture, we demonstrate highly accurate quantitation of xenon gas volumes and avoid gravitational effects on gas distribution. This study provides a foundation for other researchers to use and test these methods with the goal of clinical translation.


Assuntos
Algoritmos , Ventilação Pulmonar/fisiologia , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Xenônio/administração & dosagem , Animais , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Pulmão/diagnóstico por imagem , Pulmão/efeitos dos fármacos , Pulmão/fisiologia , Masculino , Ventilação Pulmonar/efeitos dos fármacos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos , Suínos
4.
COPD ; 6(6): 468-77, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19938971

RESUMO

The relationship between quantitative airway measurements on computed tomography (CT) and airflow limitation in individuals with severe alpha (1)-antitrypsin deficiency (AATD) is undefined. Thus, we planned to clarify the relationship between CT-based airway indices and airflow limitation in AATD. 52 patients with AATD underwent chest CT and pre-bronchodilator spirometry at three institutions. In the right upper (RUL) and lower (RLL) lobes, wall area percent (WA%) and luminal area (Ai) were measured in the third, fourth, and fifth generations of the bronchi. The severity of emphysema was also calculated in each lobe and expressed as low attenuation area percent (LAA%). Correlations between obtained measurements and FEV(1)% predicted (FEV(1)%P) were evaluated by the Spearman rank correlation test. In RUL, WA% of all generations was significantly correlated with FEV(1)%P (3rd, R = -0.33, p = 0.02; 4th, R = -0.39, p = 0.004; 5th, R = -0.57, p < 0.001; respectively). Ai also showed significant correlations (3rd, R = 0.32, p = 0.02; 4th, R = 0.34, p = 0.01; 5th, R = 0.56, p < 0.001; respectively). Measured correlation coefficients improved when the airway progressed distally from the third to fifth generations. LAA% also correlated with FEV(1)%P (R = -0.51, p < 0.001). In RLL, WA% showed weak correlations with FEV(1)%P in all generations (3rd, R = -0.34, p = 0.01; 4th, R = -0.30, p = 0.03; 5th, R = -0.31, p = 0.03; respectively). Only Ai from the fifth generation significantly correlated with FEV(1)%P in this lobe (R = 0.34, p = 0.01). LAA% strongly correlated with FEV(1)%P (R = -0.71, p < 0.001). We conclude therefore that quantitative airway measurements are significantly correlated with airflow limitation in AATD, particularly in the distal airways of RUL. Emphysema of the lower lung is the predominant component; however, airway disease also has a significant impact on airflow limitation in AATD.


Assuntos
Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/epidemiologia , Ventilação Pulmonar/fisiologia , Tomografia Computadorizada por Raios X/métodos , Deficiência de alfa 1-Antitripsina/diagnóstico por imagem , Deficiência de alfa 1-Antitripsina/epidemiologia , Análise de Variância , Estudos de Coortes , Feminino , Volume Expiratório Forçado , Humanos , Modelos Lineares , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Enfisema Pulmonar/fisiopatologia , Reprodutibilidade dos Testes , Testes de Função Respiratória , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Fumar/efeitos adversos , Fumar/epidemiologia , Deficiência de alfa 1-Antitripsina/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA