Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Magn Reson Imaging ; 2024 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-38240166

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) intervention is an established prophylactic measure. Identifying high-benefit patients poses challenges. PURPOSE: To assess the prognostic value of cardiac magnetic resonance imaging (MRI) parameters including myocardial deformation for risk stratification of ICD intervention in non-ischemic cardiomyopathy (NICM) while accounting for competing mortality risk. STUDY TYPE: Retrospective and prospective. POPULATION: One hundred and fifty-nine NICM patients eligible for primary ICD (117 male, 54 ± 13 years) and 49 control subjects (38 male, 53 ± 5 years). FIELD STRENGTH/SEQUENCE: Balanced steady state free precession (bSSFP) and three-dimensional phase-sensitive inversion-recovery late gadolinium enhancement (LGE) sequences at 1.5 T or 3 T. ASSESSMENT: Patients underwent MRI before ICD implantation and were followed up. Functional parameters, left ventricular global radial, circumferential and longitudinal strain, right ventricular free wall longitudinal strain (RV FWLS) and left atrial strain were measured (Circle, cvi42). LGE presence was assessed visually. The primary endpoint was appropriate ICD intervention. Models were developed to determine outcome, with and without accounting for competing risk (non-sudden cardiac death), and compared to a baseline model including LGE and clinical features. STATISTICAL TESTS: Wilcoxon non-parametric test, Cox's proportional hazards regression, Fine-Gray competing risk model, and cumulative incidence functions. Harrell's c statistic was used for model selection. A P value <0.05 was considered statistically significant. RESULTS: Follow-up duration was 1176 ± 960 days (median: 896). Twenty-six patients (16%) met the primary endpoint. RV FWLS demonstrated a significant difference between patients with and without events (-12.5% ± 5 vs. -16.4% ± 5.5). Univariable analyses showed LGE and RV FWLS were significantly associated with outcome (LGE: hazard ratio [HR] = 3.69, 95% CI = 1.28-10.62; RV FWLS: HR = 2.04, 95% CI = 1.30-3.22). RV FWLS significantly improved the prognostic value of baseline model and remained significant in multivariable analysis, accounting for competing risk (HR = 1.73, 95% CI = 1.12-2.66). DATA CONCLUSIONS: In NICM, RV FWLS may provide additional predictive value for predicting appropriate ICD intervention. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 5.

2.
Int J Cardiovasc Imaging ; 36(1): 91-100, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31414256

RESUMO

Transthoracic echocardiography (TTE) is the primary clinical imaging modality for the assessment of patients with isolated aortic regurgitation (AR) in whom TTE's linear left ventricular (LV) dimension is used to assess disease severity to guide aortic valve replacement (AVR), yet TTE is relatively limited with regards to its integrated semi-quantitative/qualitative approach. We therefore compared TTE and cardiovascular magnetic resonance (CMR) assessment of isolated AR and investigated each modality's ability to predict LV remodeling after AVR. AR severity grading by CMR and TTE were compared in 101 consecutive patients referred for CMR assessment of chronic AR. LV end-diastolic diameter and end-systolic diameter measurements by both modalities were compared. Twenty-four patients subsequently had isolated AVR. The pre-AVR estimates of regurgitation severity by CMR and TTE were correlated with favorable post-AVR LV remodeling. AR severity grade agreement between CMR and TTE was moderate (ρ = 0.317, P = 0.001). TTE underestimated CMR LV end-diastolic and LV end-systolic diameter by 6.6 mm (P < 0.001, CI 5.8-7.7) and 5.9 mm (P < 0.001, CI 4.1-7.6), respectively. The correlation of post-AVR LV remodeling with CMR AR grade (ρ = 0.578, P = 0.004) and AR volumes (R = 0.664, P < 0.001) was stronger in comparison to TTE (ρ = 0.511, P = 0.011; R = 0.318, P = 0.2). In chronic AR, CMR provides more prognostic relevant information than TTE in assessing AR severity. CMR should be considered in the management of chronic AR patients being considered for AVR.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler , Imagem Cinética por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Idoso , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Doença Crônica , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
3.
Magn Reson Med ; 81(5): 3192-3201, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30565296

RESUMO

PURPOSE: To develop a gadolinium-free cardiac MR technique that simultaneously exploits native T1 and magnetization transfer (MT) contrast for the imaging of myocardial infarction. METHODS: A novel hybrid T one and magnetization transfer (HYTOM) method was developed based on the modified look-locker inversion recovery (MOLLI) sequence, with a train of MT-prep pulses placed before the balanced SSFP (bSSFP) readout pulses. Numerical simulations, based on Bloch-McConnell equations, were performed to investigate the effects of MT induced by (1) the bSSFP readout pulses, and (2) the MT-prep pulses, on the measured, "apparent," native T1 values. The HYTOM method was then tested on 8 healthy adult subjects, 6 patients, and a swine with prior myocardial infarction (MI). The resulting imaging contrast between normal myocardium and infarcted tissues was compared with that of MOLLI. Late gadolinium enhancement (LGE) images were also obtained for infarct assessment in patients and swine. RESULTS: Numerical simulation and in vivo studies in healthy volunteers demonstrated that MT effects, resulting from on-resonance bSSFP excitation pulses and off-resonance MT-prep pulses, reduce the measured T1 in both MOLLI and HTYOM. In vivo studies in patients and swine showed that the HYTOM sequence can identify locations of MI, as seen on LGE. Furthermore, the HYTOM method yields higher myocardium-to-scar contrast than MOLLI (contrast-to-noise ratio: 7.33 ± 1.67 vs. 3.77 ± 0.66, P < 0.01). CONCLUSION: The proposed HYTOM method simultaneously exploits native T1 and MT contrast and significantly boosts the imaging contrast for myocardial infarction.


Assuntos
Meios de Contraste/administração & dosagem , Gadolínio/administração & dosagem , Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Adulto , Idoso , Animais , Simulação por Computador , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Magnetismo , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Distribuição Normal , Estudos Prospectivos , Suínos , Adulto Jovem
4.
Magn Reson Med ; 73(1): 214-22, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24554395

RESUMO

PURPOSE: To develop a three-dimensional (3D) free-breathing myocardial T1 mapping sequence for assessment of left ventricle diffuse fibrosis after contrast administration. METHODS: In the proposed sequence, multiple 3D inversion recovery images are acquired in an interleaved manner. A mixed prospective/retrospective navigator scheme is used to obtain the 3D Cartesian k-space data with fully sampled center and randomly undersampled outer k-space. The resulting undersampled 3D k-space data are then reconstructed using compressed sensing. Subsequently, T1 maps are generated by voxel-wise curve fitting of the individual interleaved images. In a phantom study, the accuracy of the 3D sequence was evaluated against two-dimensional (2D) modified Look-Locker inversion recovery (MOLLI) and spin-echo sequences. In vivo T1 times of the proposed method were compared with 2D multislice MOLLI T1 mapping. Subsequently, the feasibility of high-resolution 3D T1 mapping with spatial resolution of 1.7 × 1.7 × 4 mm(3) was demonstrated. RESULTS: The proposed method shows good agreement with 2D MOLLI and the spin-echo reference in phantom. No significant difference was found in the in vivo T1 times estimated using the proposed sequence and the 2D MOLLI technique (myocardium, 330 ± 66 ms versus 319 ± 93 ms; blood pools, 211 ± 68 ms versus 210 ± 98 ms). However, improved homogeneity, as measured using standard deviation of the T1 signal, was observed in the 3D T1 maps. CONCLUSION: The proposed sequence enables high-resolution 3D T1 mapping after contrast injection during free-breathing with volumetric left ventricle coverage.


Assuntos
Algoritmos , Ventrículos do Coração/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Disfunção Ventricular Esquerda/patologia , Adulto , Feminino , Fibrose , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade
5.
Magn Reson Med ; 70(3): 851-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23065722

RESUMO

Phase contrast (PC) cardiac MR is widely used for the clinical assessment of blood flow in cardiovascular disease. One of the challenges of PC cardiac MR is the long scan time which limits both spatial and temporal resolution. Compressed sensing reconstruction with accelerated PC acquisitions is a promising technique to increase the scan efficiency. In this study, we sought to use the sparsity of the complex difference of the two flow-encoded images as an additional constraint term to improve the compressed sensing reconstruction of the corresponding accelerated PC data acquisition. Using retrospectively under-sampled data, the proposed reconstruction technique was optimized and validated in vivo on 15 healthy subjects. Then, prospectively under-sampled data was acquired on 11 healthy subjects and reconstructed with the proposed technique. The results show that there is good agreement between the cardiac output measurements from the fully sampled data and the proposed compressed sensing reconstruction method using complex difference sparsity up to acceleration rate 5. In conclusion, we have developed and evaluated an improved reconstruction technique for accelerated PC cardiac MR that uses the sparsity of the complex difference of the two flow-encoded images.


Assuntos
Aorta/fisiologia , Imageamento por Ressonância Magnética/métodos , Débito Cardíaco , Humanos , Angiografia por Ressonância Magnética/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA