1.
J Clin Med ; 12(23)2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38068550

RESUMO

BACKGROUND: Patients with infectious complications related to the presence of cardiac implantable electronic devices (CIED) constitute a heterogeneous group, ranging from local pocket infection (PI) to lead-related infectious endocarditis (LRIE) infection spreading along the leads to the endocardium. The detection of isolated LRIE and the assessment of the spread of infection in a patient with PI is often difficult and requires complex imaging and microbiological tests. The aim of the current study is to evaluate the usefulness of new simple hematological parameters in detecting infectious complications in patients with CIED, differentiating vegetation and vegetation-like masses, and assessing the extent of infections in patients with PI. METHODS: A retrospective analysis of clinical data of 2909 patients (36.37% with CIED-related infections), undergoing transvenous lead extraction (TLE) procedures in three high-volume centres in the years 2006-2020, was conducted. Receiver operating characteristic (ROC) curve analysis was used to assess the sensitivity and specificity of neutrophil-to-lymphocyte ratio (NLR), neutrophil-to-platelet ratio (NPR), and lymphocyte-to-platelet ratio (LPR) in the diagnosis of CIED infections, evaluate the spread of the infectious process in patients with PI and differentiate additional structures related to the presence of lead. RESULTS: The values of NLR and NPR were significantly higher in infectious patients than non-infectious controls (3.07 vs. 2.59; p < 0.001, and 0.02 vs. 0.01; p = 0.008) and the area under the ROC curve (AUC) was 0.59; p < 0.001 and 0.56; p < 0.001, respectively. The high specificity of the new markers in detecting the infectious process was demonstrated: 72.82% for NLR (optimal cut-off value: 3.06) and 79.47% for NPR (optimal cut off value: 0.02). The values of NLR and NPR were significantly higher in patients with vegetations than in non-infectious patients with the presence of additional lead-related masses (3.37 vs. 2.61; p < 0.001 and 0.03 vs. 0.02; p = 0.008). The AUC of NLR and NPR for the prediction of vegetations was 0.65; p < 0.001 and 0.60; p < 0.001 with the highest specificity of NPR (82.78%) and an optimal cut-off value of 0.03. NLR and NPR were higher in patients with LRIE compared to isolated PI (4.11 vs. 2.56; p < 0.001 and 0.03 vs. 0.02; p < 0.001) and the ROC curve analysis for coexistence LRIE with PI showed the AUC for NLR: 0.57; p < 0.001 and AUC for NPR: 0.55; p = 0.001. High specificity in the detection of coexistence between PI and LRIE was demonstrated for NLR (87.33%), with an optimal cut-off value of 3.13. CONCLUSIONS: Novel hematological markers (NLR and NPR) are characterized by high specificity in the initial diagnosis of CIED infections, with optimal cut-off values of 3.06 and 0.02. NLR is also useful in the assessment of the spread of infection in patients with PI, with a calculated optimal cut-off value of 3.13. NPR may be helpful in the differentiation of vegetation and vegetation-like masses with an optimal cut-off value of 0.03.

2.
BMJ Open ; 12(12): e062952, 2022 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-36581437

RESUMO

OBJECTIVES: To estimate the impact of the organisational model of transvenous lead extraction (TLE) on effectiveness and safety of procedures. DESIGN: Post hoc analysis of patient data entered prospectively into a computer database. SETTING: Data of all patients undergoing TLE in three centres in Poland between 2006 and 2021 were analysed. PARTICIPANTS: 3462 patients including: 985 patients undergoing TLE in a hybrid room (HR), with cardiac surgeon (CS) as co-operator, under general anaesthesia (GA), with arterial line (AL) and with transoesophageal echocardiography (TEE) monitoring (group 1), 68 patients-TLE in HR with CS, under GA, without TEE (group 2), 406 patients-TLE in operating theatre (OT) using 'arm-C' X-ray machine with CS under GA and with TEE (group 3), 154 patients-TLE in OT with CS under GA, without TEE (group 4), 113 patients-TLE in OT with anaesthesia team, using the 'arm-C' X-ray machine, without CS (group 5), 122 patients-TLE in electrophysiology lab (EPL), with CS under intravenous analgesia without TEE and AL (group 6), 1614 patients-TLE in EPL, without CS, under intravenous analgesia without TEE and AL (group 7). KEY OUTCOME MEASURE: Effectiveness and safety of TLE depending on organisational model. RESULTS: The rate of major complications (MC) was higher in OT/HR than in EPL (2.66% vs 1.38%), but all MCs were treated successfully and there was no MC-related death. The use of TEE during TLE increased probability of complete procedural succemss achieving about 1.5 times (OR=1.482; p<0.034) and were connected with reduction of minor complications occurrence (OR=0.751; p=0.046). CONCLUSIONS: The most important condition to avoid death due to MC is close co-operation with cardiac surgery team, which permits for urgent rescue cardiac surgery. Continuous TEE monitoring plays predominant role in immediate decision on rescue sternotomy and improves the effectiveness of procedure.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Modelos Organizacionais , Resultado do Tratamento , Polônia , Remoção de Dispositivo/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA