Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 34(8): 1589-92, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23449648

RESUMO

BACKGROUND AND PURPOSE: Novel angiographic grading scales for the assessment of intracranial aneurysms treated with flow-diverting stents have been recently developed because previous angiographic grading scales cannot be applied to these aneurysms. The purpose of this study was to evaluate the inter- and intraobserver variability of the novel O'Kelly Marotta grading scale, which was developed specifically for the angiographic assessment of aneurysms treated with flow-diverting stents. MATERIALS AND METHODS: Multiple raters (n = 31) from the disciplines of neuroradiology and neurosurgery were presented with pre- and posttreatment angiographic images of 14 aneurysms treated with intraluminal flow diverters. Raters were asked to classify pre- and posttreatment angiograms by using the OKM grading scale. Statistical analyses were subsequently performed with calculation of a generalized multirater κ statistic for assessment of inter- and intraobserver variability and by performing a Wilcoxon signed rank sum test for assessment of group differences. RESULTS: Variability analysis of the OKM grading scale yielded substantial (κ = 0.74) and almost perfect (κ = 0.99) inter- and intraobserver agreement, respectively, with no statistically significant differences between raters with a background of neuroradiology versus neurosurgery or attending physician versus trainee. CONCLUSIONS: The OKM grading scale for the assessment of intracranial aneurysms treated with flow-diverting stents is a reliable grading scale that can be used equally well by users of varying backgrounds and levels of training. Comparison with interobserver variability of pre-existing angiographic grading scales shows equal or better performance.


Assuntos
Prótese Vascular , Angiografia Cerebral/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Índice de Gravidade de Doença , Stents , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
2.
Interv Neuroradiol ; 16(2): 133-7, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20642887

RESUMO

Flow diverting stents are emerging as a treatment option for difficult intracranial aneurysms. Current grading scales for assessment of angiographic outcomes following aneurysm treatment do not apply to aneurysms treated by flow diversion. We propose a novel grading scale based on the degree of angiographic filling and contrast stasis. This scale will facilitate communication and standardize reporting of outcomes following flow diversion treatments.


Assuntos
Angiografia Cerebral/métodos , Circulação Cerebrovascular , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Índice de Gravidade de Doença , Stents , Humanos , Valor Preditivo dos Testes , Hemorragia Subaracnóidea/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA