1.
J Appl Clin Med Phys ; 23(6): e13603, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35429102

RESUMO

PURPOSE: Calibration of a radiotherapy electronic portal imaging device (EPID) using the pixel-sensitivity-map (PSM) in place of the flood field correction improves the utility of the EPID for quality assurance applications. Multiple methods are available for determining the PSM and this study provides an evaluation to inform on which is superior. METHODS: Three different empirical methods ("Calvary Mater Newcastle" [CMN], "Varian," and "WashU") and a Monte Carlo-based method of PSM determination were investigated on a single Varian TrueBeam STx linear accelerator (linac) with an aS1200 EPID panel. PSM measurements were performed for each empirical method three successive times using the 6 MV beam. The resulting PSM from each method was compared to the Monte Carlo method as a reference using 2D percentage deviation maps and histograms plus crossplane profiles. The repeatability of generated PSMs was also assessed via 2D standard deviation (SD) maps and histograms. Additionally, the Beam-Response generated by removal of the PSM from a raw EPID image for each method was visually contrasted. Finally, the practicality of each method was assessed qualitatively and via the measured time required to acquire and export the required images. RESULTS: The median pixel-by-pixel percentage deviation between each of the empirical PSM methods and the Monte Carlo PSM was -0.36%, 0.24%, and 0.74% for the CMN, Varian, and WashU methods, respectively. Ninety-five percent of pixels were found to be repeatable to within -0.21%, 0.08%, 0.19%, and 0.35% (1 SD) for the CMN, Monte Carlo, Varian, and WashU methods, respectively. The WashU method was found to be quickest for data acquisition and export and the CMN the slowest. CONCLUSION: For the first time four methods of generating the EPID PSM have been compared in detail and strengths and weaknesses of each method have been identified. All methods are considered likely to be clinically acceptable and with similar practical requirements.


Assuntos
Radioterapia de Intensidade Modulada , Calibragem , Eletrônica , Humanos , Método de Monte Carlo , Aceleradores de Partículas , Radiometria/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
2.
Biomed Phys Eng Express ; 7(3)2021 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-33836524

RESUMO

Purpose. To compare the accuracies of the AAA and AcurosXB dose calculation algorithms and to predict the change in the down-stream and lateral dose deposition of high energy photons in the presence of material with densities higher that commonly found in the body.Method. Metal rods of titanium (d = 4.5 g cm-3), stainless steel (d = 8 g cm-3) and tungsten (d = 19.25 g cm-3) were positioned in a phantom. Film was position behind and laterally to the rods to measure the dose distribution for a 6 MV, 18 MV and 10 FFF photon beams. A DOSXYZnrc Monte Carlo simulation of the experimental setup was performed. The AAA and AcurosXB dose calculation algorithms were used to predict the dose distributions. The dose from film and DOSXYZnrc were compared with the dose predicted by AAA and AcurosXB.Results. AAA overestimated the dose behind the rods by 15%-25% and underestimated the dose laterally to the rods by 5%-15% depending on the range of materials and energies investigated. AcurosXB overestimated the dose behind the rods by 1%-18% and underestimated the dose laterally to the rods by up to 5% depending on the range of material and energies investigated.Conclusion. AAA cannot deliver clinically acceptable dose calculation results at a distance less than 10 mm from metals, for a single field treatment. Acuros XB is able to handle metals of low atomic numbers (Z ≤ 26), but not tungsten (Z = 74). This can be due to the restriction of the CT-density table in EclipseTMTPS, which has an upper HU limit of 10501.


Assuntos
Algoritmos , Planejamento da Radioterapia Assistida por Computador , Metais , Método de Monte Carlo , Imagens de Fantasmas , Fótons
3.
J Appl Clin Med Phys ; 17(3): 475-485, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167252

RESUMO

The metallic fixations used in surgical procedures to support the spine mechani-cally usually consist of high-density materials. Radiation therapy to palliate spinal cord compression can include prophylactic inclusion of potential tumor around the site of such fixation devices. Determination of the correct density and shape of the spine fixation device has a direct effect on the dose calculation of the radiation field. Even with the application of modern computed tomography (CT), under- or overestimation of dose, both immediately next to the device and in the surround-ing tissues, can occur due to inaccuracies in the dose prediction algorithm. In this study, two commercially available dose prediction algorithms (Eclipse AAA and ACUROS), EGSnrc Monte Carlo, and GAFchromic film measurements were com-pared for a clinical spine SBRT case to determine their accuracy. An open six-field plan and a clinical nine-field IMRT plan were applied to a phantom containing a metal spine fixation device. Dose difference and gamma analysis were performed in and around the tumor region adjacent to the fixation device. Dose calculation inconsistency was observed in the open field plan. However, in the IMRT plan, the dose perturbation effect was not observed beyond 5 mm. Our results suggest that the dose effect of the metal fixation device to the spinal cord and the tumor volume is not observable, and all dose calculation algorithms evaluated can provide clinically acceptable accuracy in the case of spinal SBRT, with the tolerance of 95% for gamma criteria of 3%/3 mm.


Assuntos
Algoritmos , Metais/química , Imagens de Fantasmas , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Coluna Vertebral/cirurgia , Simulação por Computador , Humanos , Método de Monte Carlo , Radiocirurgia/métodos , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X
4.
Med Phys ; 42(2): 856-65, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25652498

RESUMO

PURPOSE: MRI-guided radiation therapy systems (MRIgRT) are being developed to improve online imaging during treatment delivery. At present, the operation of single point dosimeters and an ionization chamber array have been characterized in such systems. This work investigates a novel 2D diode array, named "magic plate," for both single point calibration and 2D positional performance, the latter being a key element of modern radiotherapy techniques that will be delivered by these systems. METHODS: geant4 Monte Carlo methods have been employed to study the dose response of a silicon diode array to 6 MV photon beams, in the presence of in-line and perpendicularly aligned uniform magnetic fields. The array consists of 121 silicon diodes (dimensions 1.5 × 1.5 × 0.38 mm(3)) embedded in kapton substrate with 1 cm pitch, spanning a 10 × 10 cm(2) area in total. A geometrically identical, water equivalent volume was simulated concurrently for comparison. The dose response of the silicon diode array was assessed for various photon beam field shapes and sizes, including an IMRT field, at 1 T. The dose response was further investigated at larger magnetic field strengths (1.5 and 3 T) for a 4 × 4 cm(2) photon field size. RESULTS: The magic plate diode array shows excellent correspondence (< ± 1%) to water dose in the in-line orientation, for all beam arrangements and magnetic field strengths investigated. The perpendicular orientation, however, exhibits a dose shift with respect to water at the high-dose-gradient beam edge of jaw-defined fields [maximum (4.3 ± 0.8)% over-response, maximum (1.8 ± 0.8)% under-response on opposing side for 1 T, uncertainty 1σ]. The trend is not evident in areas with in-field dose gradients typical of IMRT dose maps. CONCLUSIONS: A novel 121 pixel silicon diode array detector has been characterized by Monte Carlo simulation for its performance inside magnetic fields representative of current prototype and proposed MRI-linear accelerator systems. In the in-line orientation, the silicon dose is directly proportional to the water dose. In the perpendicular orientation, there is a shift in dose response relative to water in the highest dose gradient regions, at the edge of jaw-defined and single-segment MLC fields. The trend was not observed in-field for an IMRT beam. The array is expected to be a valuable tool in MRIgRT dosimetry.


Assuntos
Imageamento por Ressonância Magnética , Método de Monte Carlo , Aceleradores de Partículas , Radioterapia Guiada por Imagem/instrumentação , Silício , Doses de Radiação , Radioterapia de Intensidade Modulada