Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Magn Reson Imaging ; 47(2): 565-571, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28577333

RESUMO

PURPOSE: To quantify the acute effect of the head-down tilt (HDT) posture on intracranial hemodynamics and hydrodynamics. MATERIALS AND METHODS: We evaluated the intracranial physiological parameters, blood flow-related parameters, and brain morphology in the HDT (-6° and -12°) and the horizontal supine (HS) positions. Seven and 15 healthy subjects were scanned for each position using 3.0 T magnetic resonance imaging system. The peak-to-peak intracranial volume change, the peak-to-peak cerebrospinal fluid (CSF) pressure gradient (PGp-p ), and the intracranial compliance index were calculated from the blood and CSF flow determined using a cine phase-contrast technique. The brain volumetry was conducted using SPM12. The measurements were compared using the Wilcoxon signed-rank test or a paired t-test. RESULTS: No measurements changed in the -6° HDT. The PGp-p and venous outflow of the internal jugular veins (IJVs) in the -12° HDT were significantly increased compared to the HS (P < 0.001 and P = 0.025, respectively). The cross-sectional areas of the IJVs were significantly larger (P < 0.001), and the maximum, minimum, and mean blood flow velocity of the IJVs were significantly decreased (P = 0.003, < 0.001, and = 0.001, respectively) in the -12° HDT. The mean blood flow velocities of the internal carotid arteries were decreased (P = 0.023). Neither position affected the brain volume. CONCLUSION: Pressure gradient and venous outflow were increased in accordance with the elevation of the intracranial pressure as an acute effect of the HDT. However, the CSF was not constantly shifted from the spinal canal to the cranium. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:565-571.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Decúbito Inclinado com Rebaixamento da Cabeça/fisiologia , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética/métodos , Humanos , Hidrodinâmica , Masculino , Estudos Prospectivos , Valores de Referência
2.
PLoS One ; 12(8): e0182042, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28792959

RESUMO

Ultrasonography (US) is useful for visual detection of edematous tissues to assess subcutaneous echogenicity. However, visualization of subcutaneous echogenicity is interpreted differently among operators because the evaluation is subjective and individual operators have unique knowledge. This study objectively assessed leg edema using US with a gel pad including fat for normalization of echogenicity in subcutaneous tissue. Five younger adults and four elderly people with leg edema were recruited. We compared assessments of US and limb circumference before and after the intervention of vibration to decrease edema in younger adults, and edema prior to going to sleep and reduced edema in the early morning in elderly people. These assessments were performed twice in elderly people by three operators and reliability, interrater differences, and bias were assessed. For US assessment, echogenicity in subcutaneous tissue was normalized to that of the gel pad by dividing the mean echogenicity of subcutaneous tissue by the mean echogenicity of the gel pad. In younger adults, the normalized subcutaneous echogenicity before the intervention was significantly higher than that after the intervention. In elderly people, echogenicity indicating edema was significantly higher than that after edema reduction. Edema was detected with accuracy rates of 76.9% in younger adults and 75.0% in elderly people. Meanwhile, limb circumference could be used to detect edema in 50.0% of healthy adults and 87.8% of elderly people. The intra-reliability was excellent (intraclass correlation coefficient > 0.9, p < 0.01), and the inter-reliability was good (intraclass correlation coefficient > 0.7, p < 0.01) for normalized subcutaneous echogenicity. Bland-Altman plots revealed that inter-rater differences and systematic bias were small. Normalized subcutaneous echogenicity with the pad can sensitively and objectively assess leg edema with high reliability. Therefore, this method has the potential to become a new gold standard for objective assessment of leg edema in clinical practice.


Assuntos
Edema/diagnóstico por imagem , Gordura Subcutânea/diagnóstico por imagem , Tela Subcutânea/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Pesos e Medidas Corporais/métodos , Erros de Diagnóstico , Edema/diagnóstico , Feminino , Humanos , Masculino , Adulto Jovem
3.
Diagnostics (Basel) ; 5(2): 210-8, 2015 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-26854150

RESUMO

Our purpose in this study was to assess the relationship between contrast signal intensity (CI) and concentration of perflubutane microbubbles in a phantom experiment, and to examine the feasibility of this technique for quantitative analysis of vascularity in hepatocellular carcinoma (HCC). Microbubble solutions of the perflubutane contrast agent were prepared by mixing with purified water. We examined the relationship between CI in dB units and the concentration. Moreover, seven HCC patients were examined using real-time dynamic contrast imaging. The perfusion index was calculated from time-intensity curves generated for both HCC and surrounding liver parenchyma. We observed a linear relationship between the CIdB and the concentration in the phantom study and a higher perfusion index in the HCC lesions relative to the surrounding liver parenchyma. Dynamic contrast-enhanced ultrasonography with perflubutane microbubbles, which exhibit linear and temporally stable characteristics under continuous ultrasound exposure, allows the collection of quantitative hemodynamic information regarding HCC.

4.
SAGE Open Med ; 3: 2050312115613351, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-27092255

RESUMO

OBJECTIVE: Lymphoedema involves swelling, especially in the subcutaneous tissues. For lymphoedema management to be successful, it is necessary to remove the interstitial fluid. Subcutaneous echogenicity may be associated with interstitial fluid, but echogenicity is not an indicator for the evaluation of management because we do not directly compare echogenicity with the interstitial fluid. We aimed to identify an outcome indicator for the evaluation of interstitial fluid using ultrasonography. We assessed the correlation between echogenicity and transverse relaxation rate (R2) on magnetic resonance imaging. METHODS: This was an observational study. Healthy adults with leg swelling after activity for >8 h were recruited. The legs of 13 women were evaluated using ultrasonography, magnetic resonance imaging and measurements of the limb circumference before and after an intervention to reduce the swelling. RESULTS: Echogenicity in the oedema group was greater than that of the controls. Echogenicity decreased with reductions in oedema. The range of the strongest correlations with the changes in R2 occurred at echogenicity values of 48-144 (Pearson's correlation coefficient: r = -0.63 and p < 0.01). Thus, it was possible to evaluate the interstitial fluid using echogenicity. CONCLUSION: The outcome indicators for the evaluation of interstitial fluid using ultrasonography were echogenicities in the range of 48-144, and these values were valid for assessing the interstitial fluid in the subcutaneous tissue.

5.
Radiol Phys Technol ; 6(1): 219-25, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23224694

RESUMO

The focus of this study was on the investigation of the accuracy of the fat fraction of the liver by use of single-breath-holding magnetic resonance spectroscopy (MRS) with T (2) correction. Single-voxel proton MRS was performed with several TE values, and the fat fraction was determined with and without T (2) correction. MRS was also performed with use of the point-resolved spectroscopy sequence in single breath holding. The T (2) values of both water and fat were determined separately at the same time, and the effect of T (2) on the fat fraction was corrected. In addition, MRS-based fat fractions were compared with the degree of hepatic steatosis (HS) by liver biopsy in human subjects. With T (2) correction, the MRI-derived fat fractions were in good agreement with the fat fractions in all phantoms, but the fat fractions were overestimated without T (2) correction. R (2) values were in good agreement with the preset iron concentrations in the phantoms. The MRI-derived fat fraction was well correlated with the degree of HS. Iron deposited in the liver affects the signal strength when proton MRS is used for detection of the fat signal in the liver. However, the fat signal can be evaluated more accurately when the T (2) correction is applied. Breath-holding MRS minimizes the respiratory motion, and it can be more accurate in the quantification of the hepatic fat fraction.


Assuntos
Tecido Adiposo/patologia , Suspensão da Respiração , Fígado/patologia , Espectroscopia de Ressonância Magnética/instrumentação , Imagens de Fantasmas , Adulto , Idoso , Dislipidemias/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA