Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
EuroIntervention ; 19(11): e891-e902, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37960875

RESUMO

BACKGROUND: Even with intracoronary imaging-guided stent optimisation, suboptimal haemodynamic outcomes post-percutaneous coronary intervention (PCI) can be related to residual lesions in non-stented segments. Preprocedural assessment of pathophysiological coronary artery disease (CAD) patterns could help predict the physiological response to PCI. AIMS: The aim of this study was to assess the relationship between preprocedural pathophysiological haemodynamic patterns and intracoronary imaging findings, as well as their association with physiological outcomes immediately post-PCI. METHODS: Data from 206 patients with chronic coronary syndrome enrolled in the ASET-JAPAN study were analysed. Pathophysiological CAD patterns were characterised using Murray law-based quantitative flow ratio (µQFR)-derived indices acquired from pre-PCI angiograms. The diffuseness of CAD was defined by the pullback pressure gradient (PPG) index. Intracoronary imaging in stented segments after stent optimisation was also analysed. RESULTS: In the multivariable analysis, diffuse disease - defined by the pre-PCI µQFR-PPG index - was an independent factor for predicting a post-PCI µQFR <0.91 (per 0.1 decrease of PPG index, odds ratio 1.57, 95% confidence interval: 1.07-2.34; p=0.022), whereas the stent expansion index (EI) was not associated with a suboptimal post-PCI µQFR. Among vessels with an EI ≥80% and post-PCI µQFR <0.91, 84.0% of those vessels had a diffuse pattern preprocedure. There was no significant difference in EI between vessels with diffuse disease and those with focal disease. The average plaque burden in the stented segment was significantly larger in vessels with a preprocedural diffuse CAD pattern. CONCLUSIONS: A physiological diffuse pattern preprocedure was an independent factor in predicting unfavourable immediate haemodynamic outcomes post-PCI, even after stent optimisation using intracoronary imaging. Preprocedural assessment of CAD patterns could identify patients who are likely to exhibit superior immediate haemodynamic outcomes following PCI.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Vasos Coronários/patologia , Resultado do Tratamento , Hemodinâmica , Valor Preditivo dos Testes
2.
Circ J ; 2023 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-37839862

RESUMO

BACKGROUND: Side branch (SB) occlusion during bifurcation stenting is a serious complication. This study aimed to predict SB compromise (SBC) using optical coherence tomography (OCT).Methods and Results: Among the 168 patients who enrolled in the 3D-OCT Bifurcation Registry, 111 bifurcation lesions were analyzed to develop an OCT risk score for predicting SBC. SBC was defined as worsening of angiographic SB ostial stenosis (≥90%) immediately after stenting. On the basis of OCT before stenting, geometric parameters (SB diameter [SBd], length from proximal branching point to carina tip [BP-CT length], and distance of the polygon of confluence [dPOC]) and 3-dimensional bifurcation types (parallel or perpendicular) were evaluated. SBC occurred in 36 (32%) lesions. The parallel-type bifurcation was significantly more frequent in lesions with SBC. The receiver operating characteristic curve indicated SBd ≤1.77 mm (area under the curve [AUC]=0.73, sensitivity 64%, specificity 75%), BP-CT length ≤1.8 mm (AUC=0.83, sensitivity 86%, specificity 68%), and dPOC ≤3.96 mm (AUC=0.68, sensitivity 63%, specificity 69%) as the best cut-off values for predicting SBC. To create the OCT risk score, we assigned 1 point to each of these factors. As the score increased, the frequency of SBC increased significantly (Score 0, 0%; Score 1, 8.7%; Score 2, 28%; Score 3, 58%; Score 4, 85%; P<0.0001). CONCLUSIONS: Prediction of SBC using OCT is feasible with high probability.

3.
Clin Cardiol ; 45(6): 605-613, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35362109

RESUMO

In patients with multivessel disease (MVD), functional information on lesions improves the prognostic capability of the SYNTAX score. Quantitative flow ratio (QFR®) is an angiography-derived fractional flow reserve (FFR) that does not require a pressure wire or pharmacological hyperemia. We aimed to investigate the feasibility of QFR-based patient information in Heart Teams' discussions to determine the optimal revascularization strategy for patients with MVD. We hypothesized that there is an acceptable agreement between treatment recommendations based on the QFR approach and recommendation based on the FFR approach. The DECISION QFR study is a prospective, multicenter, randomized controlled trial that will include patients with MVD who require revascularization. Two Heart Teams comprising cardiologists and cardiac surgeons will be randomized to select a revascularization strategy (percutaneous coronary intervention or coronary artery bypass graft) according to patient information either based on QFR or on FFR. All 260 patients will be assessed by both teams with reference to the anatomical and functional SYNTAX score/SYNTAX score II 2020 derived from the allocated physiological index (QFR or FFR). The primary endpoint of the trial is the level of agreement between the treatment recommendations of both teams, assessed using Cohen's κ. As of March 2022, the patient enrollment has been completed and 230 patients have been discussed in both Heart Teams. The current trial will indicate the usefulness of QFR, which enables a wireless multivessel physiological interrogation, in the discussions of Heart Teams to determine the optimal revascularization strategy for MVD.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco
4.
PLoS One ; 17(2): e0263246, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35104282

RESUMO

AIM: To investigate the characteristics of coronary artery bifurcation type (parallel or perpendicular type) using three-dimensional (3D) optical coherence tomography (OCT), and determine the feasibility, reproducibility, assessment time and correlation with bifurcation angles measured by 3D quantitative coronary angiography (QCA). METHODS AND RESULTS: We evaluated 60 lesions at the coronary bifurcation that were treated by main vessel (MV) stenting with kissing balloon inflation (KBI) under OCT/optical frequency domain imaging (OFDI) guidance. Inter- and intra-observer agreement regarding the assessment of 3D bifurcation types were 0.88 and 0.94, respectively. The assessment times of 3D-OCT bifurcation type with OCT and OFDI were within about 30 seconds. 3D-OCT bifurcation types showed the greatest correlation with the distal bifurcation angle assessed by 3D-QCA among the three bifurcation angles (distal bifurcation angle, proximal bifurcation angle and main vessel angle), and the optimal cut-off distal bifurcation angle to predict a perpendicular type bifurcation, as determined by ROC analysis, was 51.0° (AUC 0.773, sensitivity 0.80, specificity 0.67). Based on this cut-off value for the distal bifurcation angle (51°), the diagnostic accuracy for perpendicular type bifurcation in cases with a BA ≥ 51° (n = 34) was 70.6% (24/34) and that of the parallel type bifurcation in cases of BA < 51° (n = 26) was 76.9% (20/26). CONCLUSION: Performing 3D-OCT for assessment of coronary artery bifurcation type is feasible and simple, and can be done in a short time with high reproducibility.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Idoso , Angioplastia Coronária com Balão , Área Sob a Curva , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Stents
5.
Cardiovasc Revasc Med ; 21(8): 1000-1005, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-30686620

RESUMO

BACKGROUND: Double kissing (DK) crush stenting has been reported as a superior bifurcation stenting strategy compared to culotte stenting. However, the mechanism associated with the reduction of clinical events by DK crush stenting remains unclear. We therefore investigated the thrombogenicity of DK crush stenting and culotte stenting with both bare-metal stents (BMS) and drug-eluting stents (DES) and the feasibility of a novel porcine arteriovenous shunt model. METHODS: High-resolution intracoronary imaging with optical coherence tomography (OCT) evaluated the bifurcation stenting models for thrombogenicity. RESULTS: All porcine models retained continuous circulation without blood leakage. Thrombus was macroscopically demonstrated around the bifurcation in all settings. The volume of thrombus (mm3) with BMS using DK crush/culotte and DES using DK crush/culotte were 1.38/1.19 and 0.09/0.15, respectively. Culotte stenting had more thrombus in the proximal main branch, and DK crush stenting had more at the bifurcation. Unlike DK crush stenting, culotte stenting showed malapposition in the proximal main branch and bifurcation segments. CONCLUSION: The feasibility of a porcine arteriovenous shunt model to assess thrombogenicity by OCT in bifurcation stenting technique was confirmed. OCT detected less thrombogenicity in DES when used in the bifurcation model when compared to BMS.


Assuntos
Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Stents , Trombose/diagnóstico por imagem , Tomografia de Coerência Óptica , Animais , Artérias Carótidas/cirurgia , Stents Farmacológicos , Estudos de Viabilidade , Veias Jugulares/cirurgia , Metais , Modelos Animais , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Desenho de Prótese , Sus scrofa , Trombose/etiologia , Fatores de Tempo
6.
Circ J ; 82(9): 2317-2325, 2018 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-29973472

RESUMO

BACKGROUND: We investigated the relationship between intraprocedural angiographic and echocardiographic AR severity after TAVI, and the clinical robustness of angiographic assessment. Methods and Results: In 74 consecutive patients, the echocardiographic circumferential extent (CE) of the paravalvular regurgitant jet was retrospectively measured and graded based on the VARC-2 cut-points; and angiographic post-TAVI AR was retrospectively quantified using contrast videodensitometry (VD) software that calculates the ratio of the contrast time-density integral in the LV outflow tract to that in the ascending aorta (LVOT-AR). Seventy-four echocardiograms immediately after TAVI were analyzable, while 51 aortograms were analyzable for VD. These 51 echocardiograms and VD were evaluated. Median LVOT-AR across the echocardiographic AR grades was as follows: none-trace, 0.07 (IQR, 0.05-0.11); mild, 0.12 (IQR, 0.09-0.15); and moderate, 0.17 (IQR, 0.15-0.22; P<0.05 for none-trace vs. mild, and mild vs. moderate). LVOT-AR strongly correlated with %CE (r=0.72, P<0.0001). At 1 year, the rate of the composite end-point of all-cause death or HF re-hospitalization was significantly higher in >mild AR patients compared with no-mild AR on intra-procedural echocardiography (41.5% vs. 12.4%, P=0.03) as well as in patients with LVOT-AR >0.17 compared with LVOT-AR ≤0.17 (59.5% vs. 16.6%, P=0.03). CONCLUSIONS: VD (LVOT-AR) has good intra-procedural inter-technique consistency and clinical robustness. Greater than mild post-TAVI AR, but not mild post-TAVI AR, is associated with late mortality.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Ecocardiografia Transesofagiana/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Readmissão do Paciente , Prognóstico , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
7.
Cardiovasc Interv Ther ; 33(1): 11-22, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28766253

RESUMO

Vascular reparative therapy has become a reality with bioresorbable scaffolds (BRSs). To assess acute and long-term performance of the device, multimodality imaging would be essential. Radiopacity of metal hinders the imaging assessment, whereas radiolucent polymeric scaffolds allow for a precise imaging assessment with either invasive or non-invasive modality at baseline and at follow-up, which is one of the advantages of polymeric BRSs. Recent large trials evaluating clinical results of the first-generation BRS technology raised concerns about the safety and efficacy of these devices, namely, scaffold thrombosis. Intensive research with multimodality imaging in the field is being conducted to have in-depth understanding of the issues, which will facilitate the improvement of implantation techniques and the development of the next-generation BRSs. The current review focuses on the clinical application of the imaging modalities to assess the short- and long-term performance of the Absorb BVS.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Alicerces Teciduais , Doença da Artéria Coronariana/fisiopatologia , Stents Farmacológicos , Everolimo/administração & dosagem , Regeneração Tecidual Guiada , Humanos , Imagem Multimodal , Intervenção Coronária Percutânea , Poliésteres/administração & dosagem , Desenho de Prótese , Cicatrização/fisiologia
8.
Cardiol J ; 23(6): 667-672, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27714725

RESUMO

BACKGROUND: We assessed performance of 6 aspiration catheters for distal embolization using a distal protection filter in an in vitro experiment. In acute myocardial infarction, a distal protection filter is used for lesions likely to induce a distal embolism. Which aspiration cathether is most effective when used with a distal protection filter remains still unclear. METHODS: A 0.5-cm3 bolus of gelatin as a model of stagnant pools of coronary plaque debris was captured in the distal protection filter and aspirated by 6 aspiration catheters. We measured and compared the length of the suspended embolus matter. RESULTS: Among the 6 catheters evaluated, the use of the Export Advance catheter (Medtronic) resulted in significantly shorter lengths of the suspended embolus matter compared to the use of the TVAC II (Nipro), Thrombuster III SL (Kaneka), and Rebirth Pro (Goodman) catheters (p < 0.01). The residual embolus matter in all cases had drained distally to the distal protection filter when the filter was retrieved. CONCLUSIONS: The use of the Export Advance catheter showed better performance using a distal protection filter in this in vitro experiment, and its use might be more effective in preventing distal embolisms in combination with a distal protection filter.


Assuntos
Catéteres , Embolia/prevenção & controle , Infarto do Miocárdio/cirurgia , Paracentese/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Equipamento , Humanos
9.
Rev Esp Cardiol (Engl Ed) ; 69(11): 1026-1032, 2016 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-27321644

RESUMO

INTRODUCTION AND OBJECTIVES: There is limited data on the serial morphological and functional assessment of paclitaxel-coated balloon treatment using coronary angiography, optical coherence tomography, and fractional flow reserve. METHODS: In this prospective, single-center observational study, patients with de novo lesions were treated with the paclitaxel-coated balloon. Serial angiographic, optical coherence tomography and fractional flow reserve measurements were performed before and after plain old balloon angioplasty, as well as at 9-month follow-up. RESULTS: Twenty patients (21 lesions) were enrolled in this study. The reference vessel diameter was 2.68±0.34mm and late luminal loss was 0.01±0.21mm. The median changes in the minimal lumen area between pre- and postplain old balloon angioplasty, and postplain old balloon angioplasty and follow-up were an increase of 75.2% [interquartile range of 37.2 to 164.7] and 50.0% [interquartile range of 1.1% to 64.5%], respectively. Intimal dissections were seen in all postprocedural optical coherence tomography images, and 66.6% of them were sealed on follow-up optical coherence tomography (median 278 days). The fractional flow reserve distal to the target lesion was 0.71±0.14 predilatation, 0.87±0.04 postdilatation, and 0.83±0.08 at follow-up. CONCLUSIONS: The paclitaxel-coated balloon restores coronary blood flow by means of plaque modification, causing an increment in minimal lumen area. At 9-month follow-up, coronary flow was sustained and the luminal patency was the result of suppressed luminal narrowing progression from local drug effects on the de novo coronary lesions.


Assuntos
Angina Pectoris/terapia , Angioplastia Coronária com Balão/instrumentação , Antineoplásicos Fitogênicos/uso terapêutico , Estenose Coronária/terapia , Paclitaxel/uso terapêutico , Idoso , Angina Pectoris/etiologia , Angioplastia Coronária com Balão/métodos , Angiografia Coronária , Reestenose Coronária , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento
10.
Cardiovasc Interv Ther ; 29(1): 31-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24057448

RESUMO

Understanding of intraluminal structure and distribution of uncovered struts after drug-eluting stent implantation are limited by only 2-dimensional (2D) optical coherence tomography (OCT) images. We compared tissue coverage with 3-dimensional (3D) OCT and 2D quantitative analyses, and changes in intraluminal structure immediately after (baseline) everolimus-eluting stent (EES) implantation and at follow-up. The 2D analyses of uncovered struts ratio and tissue coverage thickness at a 0.5-mm interval were compared to 3D-OCT images and visually classified for the degree of tissue coverage. The difference in tissue coverage at baseline and follow-up after EES implantation was evaluated with tissue coverage scores (TCS) calculated by the 3D-OCT classification (Grade 0-3). 3D-OCT classifications were negatively correlated with uncovered-to-total struts (r = -0.864, P < 0.001) and positively correlated with tissue coverage thickness (r = 0.905, P < 0.001). Follow-up TCS was greater than baseline TCS (0.2 ± 0.4 vs. 1.4 ± 0.5, P < 0.001). Moreover, changes in intraluminal structures and longitudinal distribution of uncovered struts were assessed. Incomplete stent appositions, in-stent dissections, and thrombi were decreased at follow-up, indicating progressive arterial healing. The distribution of uncovered-to-total struts could be assessed by 3D-OCT, which was related to 2D analysis. Significant correlations between 3D-OCT classifications and quantitative analyses were shown. The classification and visual assessment of intraluminal structures by 3D-OCT were useful in evaluating arterial healing after EES implantation.


Assuntos
Síndrome Coronariana Aguda/cirurgia , Implante de Prótese Vascular/métodos , Vasos Coronários/patologia , Stents Farmacológicos , Imageamento Tridimensional , Tomografia de Coerência Óptica/métodos , Síndrome Coronariana Aguda/diagnóstico , Idoso , Vasos Coronários/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Período Pós-Operatório , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Propriedades de Superfície , Fatores de Tempo
11.
Am Heart J ; 166(1): 83-94, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23816026

RESUMO

BACKGROUND: Histologic experimental studies have reported incomplete neointimal healing in overlapping with respect to nonoverlapping segments in drug-eluting stents (DESs), but these observations have not been confirmed in human coronary arteries hitherto. On the contrary, angiographic and optical coherence tomography studies suggest that DES overlap elicits rather an exaggerated than an incomplete neointimal reaction. METHODS: Optical coherence tomography studies from 2 randomized trials including sirolimus-eluting, biolimus-eluting, everolimus-eluting, and zotarolimus-eluting stents were analyzed at 9- to 13-month follow-up. Coverage in overlapping segments was compared versus the corresponding nonoverlapping segments of the same stents, using statistical pooled analysis. RESULTS: Forty-two overlaps were found in 31 patients: 11 in sirolimus-eluting stents, 3 in biolimus-eluting stents, 17 in everolimus-eluting stents, and 11 in zotarolimus-eluting stents. The risk ratio of incomplete coverage was 2.35 (95% CI 1.86-2.98) in overlapping versus nonoverlapping segments. Thickness of coverage in overlaps was only 85% (95% CI 81%-90%) of the thickness in nonoverlaps. Significant heterogeneity of the effect was observed, especially pronounced in the comparison of thickness of coverage (I(2) = 90.31). CONCLUSIONS: The effect of overlapping DES on neointimal inhibition is markedly heterogeneous: on average, DES overlap is associated with more incomplete and thinner coverage, but in some cases, the overlap elicits an exaggerated neointimal reaction, thicker than in the corresponding nonoverlapping segments. These results might help to understand why overlapping DES is associated with worse clinical outcomes, both in terms of thrombotic phenomena and in terms of restenosis and revascularization.


Assuntos
Estenose Coronária/cirurgia , Vasos Coronários/patologia , Stents Farmacológicos , Tomografia de Coerência Óptica/métodos , Reestenose Coronária/diagnóstico , Reestenose Coronária/prevenção & controle , Estenose Coronária/patologia , Everolimo , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Hiperplasia , Imunossupressores , Masculino , Pessoa de Meia-Idade , Neointima/patologia , Desenho de Prótese , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Fatores de Tempo , Resultado do Tratamento
13.
Circulation ; 124(5): 612-23, 2011 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-21768536

RESUMO

BACKGROUND: Pathology studies on fatal cases of very late stent thrombosis have described incomplete neointimal coverage as common substrate, in some cases appearing at side-branch struts. Intravascular ultrasound studies have described the association between incomplete stent apposition (ISA) and stent thrombosis, but the mechanism explaining this association remains unclear. Whether the neointimal coverage of nonapposed side-branch and ISA struts is delayed with respect to well-apposed struts is unknown. METHODS AND RESULTS: Optical coherence tomography studies from 178 stents implanted in 99 patients from 2 randomized trials were analyzed at 9 to 13 months of follow-up. The sample included 38 sirolimus-eluting, 33 biolimus-eluting, 57 everolimus-eluting, and 50 zotarolimus-eluting stents. Optical coherence tomography coverage of nonapposed side-branch and ISA struts was compared with well-apposed struts of the same stent by statistical pooled analysis with a random-effects model. A total of 34 120 struts were analyzed. The risk ratio of delayed coverage was 9.00 (95% confidence interval, 6.58 to 12.32) for nonapposed side-branch versus well-apposed struts, 9.10 (95% confidence interval, 7.34 to 11.28) for ISA versus well-apposed struts, and 1.73 (95% confidence interval, 1.34 to 2.23) for ISA versus nonapposed side-branch struts. Heterogeneity of the effect was observed in the comparison of ISA versus well-apposed struts (H=1.27; I(2)=38.40) but not in the other comparisons. CONCLUSIONS: Coverage of ISA and nonapposed side-branch struts is delayed with respect to well-apposed struts in drug-eluting stents, as assessed by optical coherence tomography. Clinical Trial Registration- http://www.clinicaltrials.gov. Unique identifier: NCT00389220, NCT00617084.


Assuntos
Angioplastia Coronária com Balão/estatística & dados numéricos , Reestenose Coronária/diagnóstico , Reestenose Coronária/epidemiologia , Stents Farmacológicos/estatística & dados numéricos , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Tomografia de Coerência Óptica , Idoso , Angioplastia Coronária com Balão/métodos , Vasos Coronários , Stents Farmacológicos/efeitos adversos , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Fatores de Risco
14.
JACC Cardiovasc Interv ; 3(8): 836-44, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20723856

RESUMO

OBJECTIVES: The purpose of this study is to assess jailing of side branches (SB) by the everolimus-eluting, bioresorbable vascular scaffold (BVS) with 3-dimensional (3D) optical coherence tomography (OCT) reconstruction. BACKGROUND: Because BVS struts at the SB orifice are suspected of being bioresorbed and/or forming a neointimal bridge, OCT has been used to evaluate the struts in detail at that particular site. Our understanding of the 3D relationship of the strut and the SB orifice is limited by the use of 2-dimensional OCT images. Fourier-domain OCT enables reliable 3D reconstruction of coronary vessels. METHODS: The ABSORB Cohort B (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions) trial is a multicenter single-arm trial to assess the safety and performance of the BVS. Fourier-domain OCT pullbacks (C7-XR system, LightLab Imaging Inc., Westford, Massachusetts) are obtained at pullback speed of 20 mm/s and 3D renderings are performed. The orifices of the SB are assessed visually. The area of SB orifice and the number of strut-free compartments delineated by the BVS struts are evaluated. RESULTS: Fifty-one OCT pullbacks were acquired: 33 pullbacks were imaged with Fourier-domain OCT and 27 treated segments had 46 side branches. Three-dimensional assessment was feasible in 87% (40 of 46) of pullbacks. The mean area of the SB orifice was 1.16 +/- 1.02 mm(2). The mean number of strut-free compartments was 2.0 +/- 1.1. The classification of the overhanging struts is proposed. CONCLUSIONS: This study demonstrates that 3D OCT reconstruction is feasible to evaluate the orifices of SB jailed with BVS. (ABSORB Clinical Investigation, Cohort B; NCT00856856).


Assuntos
Angioplastia Coronária com Balão/instrumentação , Estenose Coronária/terapia , Stents Farmacológicos , Imageamento Tridimensional , Tomografia de Coerência Óptica , Adulto , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Austrália , Fármacos Cardiovasculares/administração & dosagem , Estenose Coronária/patologia , Europa (Continente) , Everolimo , Estudos de Viabilidade , Feminino , Análise de Fourier , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Valor Preditivo dos Testes , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Terminologia como Assunto , Resultado do Tratamento
16.
Jpn J Infect Dis ; 61(5): 371-4, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18806344

RESUMO

This study comparatively evaluated the titers of the bacterial agglutination (BA) antibody for Bordetella pertussis, anti-pertussis toxin (PT) antibody, and anti-filamentous hemagglutinin (FHA) antibody in the serum of medical staff members. The geometric means of the anti-PT and anti-FHA antibody titers were 5.83 and 17.17 EU/mL, respectively. The positive rates of the BA antibodies against Tohama and Yamaguchi strains (> or = 40x), and anti-PT and anti-FHA antibodies (>10 EU/mL) were 81.3, 72.9, 43.8, and 68.8%, respectively. A high anti-PT antibody titer (>94 EU/mL) was found in 1 staff member, but this individual had no recent respiratory symptoms. The titers of the BA antibody against the Yamaguchi strain were weakly associated with the anti-PT antibody titers, but the BA antibody titer was not useful for predicting anti-PT antibody positivity. The seroprevalence of anti-pertussis antibody among medical staff was heterogeneous, suggesting that this group could be at high risk for pertussis. Judgments made using BA antibody or anti-PA antibody results differ, and thus careful evaluation of anti-pertussis antibody titers is necessary. Prompt and accurate diagnostic tools are crucial for infection control in the hospital setting.


Assuntos
Anticorpos Antibacterianos/sangue , Bordetella pertussis/imunologia , Corpo Clínico Hospitalar , Recursos Humanos de Enfermagem Hospitalar , Coqueluche/epidemiologia , Adulto , Anticorpos Antibacterianos/imunologia , Antígenos de Bactérias/imunologia , Feminino , Hemaglutininas/imunologia , Humanos , Controle de Infecções/métodos , Masculino , Pessoa de Meia-Idade , Toxina Pertussis/imunologia , Coqueluche/imunologia , Coqueluche/prevenção & controle
17.
Br J Haematol ; 118(4): 999-1010, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12199778

RESUMO

We studied the effectiveness of risk-directed therapy for infants younger than 13 months of age with acute lymphoblastic leukaemia (ALL). Fifty-five infants were assigned to different treatment programs (from December 1995 to December 1998) on the basis of their MLL gene status at diagnosis. Forty-two cases (76.3%) had a rearranged MLL gene (MLL+) and were treated with remission induction therapy followed by sequential intensive chemotherapy, including multiple genotoxic agents (MLL9601 protocol). Haematopoietic stem cell transplantation (HSCT) was attempted if suitable donors were available. Thirteen infants (23.7%) were classified as MLL- and treated for 2.5 years with intensive chemotherapy for high-risk B-ALL (MLL9602 protocol). Complete remission was induced in 38 of the 42 infants (90.5%) with MLL+ ALL and in all 13 patients (100%) with MLL- disease. In the MLL+ subgroup, the estimated event-free survival (EFS) rate at 3 years post diagnosis was 34.0% +/- 7.5%, compared with 92.3% +/- 7.4% in the MLL- subgroup (overall comparison, P = 0.001 by log-rank analysis). Both age less than 6 months (hazard ratio = 6.87, 95% CI = 0.91-52.3; P = 0.013) and central nervous system (CNS) involvement at diagnosis (hazard ratio = 2.92 95% CI = 1.29-6.63; P = 0.015) were significant independent predictors of an inferior outcome. These findings indicate a strategic advantage in classifying infant ALL as either MLL+ or MLL- early in the clinical course and selecting therapy accordingly. Standard chemotherapy for high-risk B-lineage ALL appeared adequate for MLL- cases. Novel therapeutic initiatives are warranted for infants with MLL+ disease, particularly those with initial CNS leukaemic involvement or age less than 6 months, or both.


Assuntos
Proteínas de Ligação a DNA/genética , Rearranjo Gênico , Leucemia-Linfoma Linfoblástico de Células Precursoras/genética , Leucemia-Linfoma Linfoblástico de Células Precursoras/terapia , Proto-Oncogenes , Fatores de Transcrição , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Análise Citogenética , Intervalo Livre de Doença , Seguimentos , Histona-Lisina N-Metiltransferase , Humanos , Imunossupressores/uso terapêutico , Hibridização in Situ Fluorescente , Lactente , Recém-Nascido , Japão , Proteína de Leucina Linfoide-Mieloide , Seleção de Pacientes , Indução de Remissão , Medição de Risco , Transplante de Células-Tronco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA