Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Hypertens ; 41(10): 1585-1594, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37466429

RESUMO

OBJECTIVE: Hypertension management is directed by cuff blood pressure (BP), but this may be inaccurate, potentially influencing cardiovascular disease (CVD) events and health costs. This study aimed to determine the impact on CVD events and related costs of the differences between cuff and invasive SBP. METHODS: Microsimulations based on Markov modelling over one year were used to determine the differences in the number of CVD events (myocardial infarction or coronary death, stroke, atrial fibrillation or heart failure) predicted by Framingham risk and total CVD health costs based on cuff SBP compared with invasive (aortic) SBP. Modelling was based on international consortium data from 1678 participants undergoing cardiac catheterization and 30 separate studies. Cuff underestimation and overestimation were defined as cuff SBP less than invasive SBP and cuff SBP greater than invasive SBP, respectively. RESULTS: The proportion of people with cuff SBP underestimation versus overestimation progressively increased as SBP increased. This reached a maximum ratio of 16 : 1 in people with hypertension grades II and III. Both the number of CVD events missed (predominantly stroke, coronary death and myocardial infarction) and associated health costs increased stepwise across levels of SBP control, as cuff SBP underestimation increased. The maximum number of CVD events potentially missed (11.8/1000 patients) and highest costs ($241 300 USD/1000 patients) were seen in people with hypertension grades II and III and with at least 15 mmHg of cuff SBP underestimation. CONCLUSION: Cuff SBP underestimation can result in potentially preventable CVD events being missed and major increases in health costs. These issues could be remedied with improved cuff SBP accuracy.


Assuntos
Doenças Cardiovasculares , Hipertensão , Infarto do Miocárdio , Acidente Vascular Cerebral , Humanos , Pressão Sanguínea/fisiologia , Aorta , Custos de Cuidados de Saúde , Fatores de Risco
2.
Connect Health ; 1: 7-35, 2022 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-35233563

RESUMO

During the COVID-19 pandemic, telemedicine has emerged worldwide as an indispensable resource to improve the surveillance of patients, curb the spread of disease, facilitate timely identification and management of ill people, but, most importantly, guarantee the continuity of care of frail patients with multiple chronic diseases. Although during COVID-19 telemedicine has thrived, and its adoption has moved forward in many countries, important gaps still remain. Major issues to be addressed to enable large scale implementation of telemedicine include: (1) establishing adequate policies to legislate telemedicine, license healthcare operators, protect patients' privacy, and implement reimbursement plans; (2) creating and disseminating practical guidelines for the routine clinical use of telemedicine in different contexts; (3) increasing in the level of integration of telemedicine with traditional healthcare services; (4) improving healthcare professionals' and patients' awareness of and willingness to use telemedicine; and (5) overcoming inequalities among countries and population subgroups due to technological, infrastructural, and economic barriers. If all these requirements are met in the near future, remote management of patients will become an indispensable resource for the healthcare systems worldwide and will ultimately improve the management of patients and the quality of care.

3.
Telemed J E Health ; 26(8): 973-975, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32324109

RESUMO

In the time of COVID-19 epidemic, Italy was found unprepared to manage lockdown patients with chronic diseases, due to limited availability and diffusion of large-scale telemedicine solutions. The scattered distribution and heterogeneity of available tools, the lack of integration with the electronic health record of the national health system, the poor interconnection between telemedicine services operating at different levels, the lack of a real multidisciplinary approach to the patient's management, the heavy privacy regulations, and lack of clear guidelines, together with the lack of reimbursement, all hinder the implementation of effective telemedicine solutions for long-term patients' management. This COVID-19 epidemic should help promote better use and a larger integration of telemedicine services in the armamentarium of health care services. Telemedicine must no longer be considered as an option or add-on to react to an emergency.


Assuntos
Infecções por Coronavirus/epidemiologia , Pneumonia Viral/epidemiologia , Quarentena/organização & administração , Telemedicina/organização & administração , Betacoronavirus , COVID-19 , Doença Crônica/terapia , Humanos , Itália/epidemiologia , Pandemias , Quarentena/normas , SARS-CoV-2 , Telemedicina/economia
4.
J Clin Hypertens (Greenwich) ; 21(12): 1784-1794, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31769171

RESUMO

The present paper reports trends in office blood pressure (BP) measurement (OBPM) and ambulatory blood pressure measurement (ABPM) with age in a large multi-center Indian all comers' population visiting primary care physicians. ABPM and OBPM data from 27 472 subjects (aged 51 ± 14 years, males 68.2%, treated 45.5%) were analyzed and compared. Individual differences between OBPM and ABPM patterns were compared for patients according to 10-year age categories. Results showed that systolic (S) BP values started to increase with age from the age of 40, BP variability (SD) increased from the age of 30 years. Diastolic (D) BP values started to decrease from the age of 50 years. Mean OBPM values were higher than daytime ABPM values (all P < .001) in all age-groups. The prevalence of white coat hypertension (WCH) and masked hypertension (MH) was based on OBPM and daytime, 24-hour, and nighttime average BPs together. WCH decreased with age from 15.1% and 12.4% in treated and untreated subjects at the youngest age to 7.2% and 6.9% in the oldest age, respectively. MH prevalence was higher for untreated than for treated subjects but remained similar for all age-groups (range of 18.6%-21.3%). The prevalence of reverse dippers increased with age from the youngest to oldest group with 7.3%-34.2% (P < .001 for trend). Dippers prevalence decreased from 42.5% to 17.9% from the youngest to oldest age-groups, respectively (P < .001 for trend). These findings confirm that BP patterns show clear differences in trends with age, particularly regarding nighttime BP.


Assuntos
Determinação da Pressão Arterial/instrumentação , Monitorização Ambulatorial da Pressão Arterial/métodos , Pressão Sanguínea/fisiologia , Hipertensão/fisiopatologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/uso terapêutico , Variação Biológica da População/fisiologia , Estudos de Casos e Controles , Ritmo Circadiano , Diástole/fisiologia , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Índia/epidemiologia , Masculino , Hipertensão Mascarada/diagnóstico , Hipertensão Mascarada/tratamento farmacológico , Hipertensão Mascarada/epidemiologia , Pessoa de Meia-Idade , Prevalência , Atenção Primária à Saúde/estatística & dados numéricos , Sístole/fisiologia , Hipertensão do Jaleco Branco/diagnóstico , Hipertensão do Jaleco Branco/tratamento farmacológico , Hipertensão do Jaleco Branco/epidemiologia
5.
J Clin Hypertens (Greenwich) ; 21(8): 1155-1168, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31294910

RESUMO

The VASOTENS Registry is an international telehealth-based repository of 24-hour ambulatory blood pressure monitorings (ABPM) obtained through an oscillometric upper-arm BP monitor allowing combined estimation of some vascular biomarkers. The present paper reports the results obtained in 1200 participants according to different categories of CV risk. Individual readings were averaged for each recording and 24-hour mean of brachial and aortic systolic (SBP) and diastolic blood pressure (DBP), pulse wave velocity (PWV), and augmentation index (AIx) obtained. Peripheral and central BP, PWV and AIx values were increased in older participants (SBP only) and in case of hypertension (SBP and DBP). BP was lower and PWV and AIx higher in females. PWV was increased and BP unchanged in case of metabolic syndrome. Our results suggest that ambulatory pulse wave analysis in a daily life setting may help evaluate vascular health of individuals at risk for CV disease.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/instrumentação , Doenças Cardiovasculares/epidemiologia , Análise de Onda de Pulso/métodos , Rigidez Vascular/fisiologia , Adulto , Idoso , Aorta/fisiopatologia , Pressão Arterial/fisiologia , Monitorização Ambulatorial da Pressão Arterial/métodos , Estudos de Casos e Controles , Estudos Transversais , Diástole , Feminino , Humanos , Hipertensão/fisiopatologia , Intervenção Baseada em Internet , Masculino , Síndrome Metabólica/fisiopatologia , Pessoa de Meia-Idade , Ensaios Clínicos Controlados não Aleatórios como Assunto , Oscilometria/instrumentação , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Sístole , Telemedicina/instrumentação
7.
JMIR Res Protoc ; 5(2): e137, 2016 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-27358088

RESUMO

BACKGROUND: Hypertension guidelines recommend ambulatory blood pressure (ABP), central aortic pressure (CAP), and pulse wave velocity (PWV) as parameters for estimating blood pressure (BP) control and vascular impairment. Recent advances in technology have enabled devices to combine non-invasive estimation of these parameters over the 24-hour ABP monitoring. However, currently there is limited evidence on the usefulness of such an approach for routine hypertension management. OBJECTIVE: We recently launched an investigator-initiated, international, multicenter, observational, prospective study, the Vascular health Assessment Of The Hypertensive patients (VASOTENS) Registry, aimed at (1) evaluating non-invasive 24-hour ABP and arterial stiffness estimates (through 24-hour pulse wave analysis, PWA) in hypertensive subjects undergoing ambulatory blood pressure monitoring (ABPM) for clinical reasons; (2) assessing the changes in estimates following treatment; (3) weighing the impact of 24-hour PWA on target organ damage and cardiovascular prognosis; (4) assessing the relationship between arterial stiffness, BP absolute mean level and variability, and prognosis; and (5) validating the use of a 24-hour PWA electronic health (e-health) solution for hypertension screening. METHODS: Approximately 2000 subjects, referred to 20 hypertension clinics for routine diagnostic evaluation and follow-up of hypertension of any severity or stage, will be recruited. Data collection will include ABPM, performed with a device allowing simultaneous non-invasive assessment of 24-hour CAP and arterial stiffness (BPLab), and clinical data (including cardiovascular outcomes). As recommended by current guidelines, each patient will be followed-up with visits occurring at regular intervals (ideally every 6 months, and not less than once a year depending on disease severity). A Web-based telemedicine platform (THOLOMEUS) will be used for data collection. The use of the telemedicine system will allow standardized and centralized data collection, data validation by experts and counseling to remote centers, setup and maintenance of the Registry, and prompt data analysis. RESULTS: First follow-up results are expected to be available in the next 2 years. CONCLUSIONS: The results of the VASOTENS Registry will help define the normalcy thresholds for current and future indices derived from 24-hour PWA, according to outcome data, and will also provide supporting evidence for the inclusion of this type of evaluation in hypertension management. TRIAL REGISTRATION: Clinicaltrials.gov NCT02577835; https://clinicaltrials.gov/ct2/show/NCT02577835 (Archived by WebCite at http://www.Webcitation.org/6hzZBKY2Q).

8.
High Blood Press Cardiovasc Prev ; 23(3): 187-96, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27072129

RESUMO

Electronic processes and communication technologies are more and more often employed to provide healthcare services to caregivers and their patients. Such solutions are currently referred as e-health, the most popular and widely distributed being those based on telemedicine and mobile health (m-health). A specific application of telemedicine for hypertension management is blood pressure telemonitoring (BPT), which allows remote data transmission of BP and additional information on patients' health status from their living site or from a community setting to the doctor's office or the hospital. Several randomized studies have documented a significant BP reduction with regular BPT compared to usual care, particularly in high risk hypertensive patients. Additional benefits are observed when BPT is offered under the supervision of a team of healthcare professionals, including a community pharmacist. BPT may also be provided in the context of m-health solutions, which commonly include wireless diagnostic and clinical decision support tools. M-health has the potential to promote patient's self-management, as a complement to the doctor's intervention, and encourage greater participation in medical decision making. Current statistics show that half of smartphone owners gather health information through their phone and 19 % use a health app. In case of hypertensive patients the most popular apps are those with tracking function, including BPT. Thus, e-health, and in particular BPT and m-health, are progressively gaining a key role in the management of hypertensive patients, having the potential to improve the quality of the delivered care and to more effectively prevent cardiovascular consequences of high BP.


Assuntos
Determinação da Pressão Arterial/instrumentação , Pressão Sanguínea , Computadores de Mão , Diagnóstico por Computador/instrumentação , Hipertensão/diagnóstico , Hipertensão/terapia , Aplicativos Móveis , Telemedicina/instrumentação , Terapia Assistida por Computador/instrumentação , Determinação da Pressão Arterial/economia , Serviços Comunitários de Farmácia , Computadores de Mão/economia , Análise Custo-Benefício , Prestação Integrada de Cuidados de Saúde , Diagnóstico por Computador/economia , Custos de Cuidados de Saúde , Nível de Saúde , Humanos , Hipertensão/economia , Hipertensão/fisiopatologia , Aplicativos Móveis/economia , Valor Preditivo dos Testes , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Telemedicina/economia , Terapia Assistida por Computador/economia , Resultado do Tratamento
9.
J Hypertens ; 32(7): 1359-66, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24886823

RESUMO

Given the increasing use of ambulatory blood pressure monitoring (ABPM) in both clinical practice and hypertension research, a group of scientists, participating in the European Society of Hypertension Working Group on blood pressure monitoring and cardiovascular variability, in year 2013 published a comprehensive position paper dealing with all aspects of the technique, based on the available scientific evidence for ABPM. The present work represents an updated schematic summary of the most important aspects related to the use of ABPM in daily practice, and is aimed at providing recommendations for proper use of this technique in a clinical setting by both specialists and practicing physicians. The present article details the requirements and the methodological issues to be addressed for using ABPM in clinical practice, The clinical indications for ABPM suggested by the available studies, among which white-coat phenomena, masked hypertension, and nocturnal hypertension, are outlined in detail, and the place of home measurement of blood pressure in relation to ABPM is discussed. The role of ABPM in pharmacological, epidemiological, and clinical research is also briefly mentioned. Finally, the implementation of ABPM in practice is considered in relation to the situation of different countries with regard to the reimbursement and the availability of ABPM in primary care practices, hospital clinics, and pharmacies.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão/diagnóstico , Adolescente , Adulto , Fibrilação Atrial/fisiopatologia , Monitorização Ambulatorial da Pressão Arterial/economia , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Monitorização Ambulatorial da Pressão Arterial/estatística & dados numéricos , Criança , Feminino , Humanos , Hipertensão/fisiopatologia , Masculino , Hipertensão Mascarada/diagnóstico , Hipertensão Mascarada/fisiopatologia , Obesidade/fisiopatologia , Padrões de Prática Médica/economia , Software , Hipertensão do Jaleco Branco/diagnóstico , Hipertensão do Jaleco Branco/fisiopatologia
10.
Blood Press ; 23(2): 102-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23926884

RESUMO

INTRODUCTION: The accuracy of impedance cardiography for cardiac index assessment is matter of debate, with available studies reporting inconsistent results. Our study aimed at evaluating the agreement between measurements of cardiac index provided by a new-generation thoracic electrical bioimpedance device (Hotman System) and an invasive approach based on thermodilution in humans. METHODS: Cardiac index was assessed simultaneously with thoracic electrical bioimpedance and conventional thermodilution through comparison of five consecutive measurements in 51 cardiac patients, hospitalized in an intensive care unit (mean± SD age: 60 ± 11 years; 68% males). The agreement between cardiac index values measured by both methods was assessed by the Bland-Altman approach, adjusted for repeated measures. The repeatability coefficient and the intraclass correlation coefficient were used to assess reproducibility of replicates. RESULTS: Average (± SD) cardiac index was 3.05 ± 0.91 l/min/m(2) with Hotman System and 3.14 ± 1.12 l/min/m(2) with thermodilution. The bias of precision was -0.09 ± 0.41. The coefficients of repeatability and intraclass correlation coefficients were high and similar for the two techniques (0.95 l/min/m(2) and 0.91 for Hotman System vs 0.78 l/min/m(2) and 0.90 for thermodilution). CONCLUSIONS: Cardiac index values yielded by Hotman system compares favorably with that obtained with thermodilution in cardiac patients.


Assuntos
Débito Cardíaco/fisiologia , Cardiografia de Impedância/métodos , Termodiluição/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
11.
J Hypertens ; 31(9): 1731-68, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24029863

RESUMO

Ambulatory blood pressure monitoring (ABPM) is being used increasingly in both clinical practice and hypertension research. Although there are many guidelines that emphasize the indications for ABPM, there is no comprehensive guideline dealing with all aspects of the technique. It was agreed at a consensus meeting on ABPM in Milan in 2011 that the 34 attendees should prepare a comprehensive position paper on the scientific evidence for ABPM.This position paper considers the historical background, the advantages and limitations of ABPM, the threshold levels for practice, and the cost-effectiveness of the technique. It examines the need for selecting an appropriate device, the accuracy of devices, the additional information and indices that ABPM devices may provide, and the software requirements.At a practical level, the paper details the requirements for using ABPM in clinical practice, editing considerations, the number of measurements required, and the circumstances, such as obesity and arrhythmias, when particular care needs to be taken when using ABPM.The clinical indications for ABPM, among which white-coat phenomena, masked hypertension, and nocturnal hypertension appear to be prominent, are outlined in detail along with special considerations that apply in certain clinical circumstances, such as childhood, the elderly and pregnancy, and in cardiovascular illness, examples being stroke and chronic renal disease, and the place of home measurement of blood pressure in relation to ABPM is appraised.The role of ABPM in research circumstances, such as pharmacological trials and in the prediction of outcome in epidemiological studies is examined and finally the implementation of ABPM in practice is considered in relation to the issue of reimbursement in different countries, the provision of the technique by primary care practices, hospital clinics and pharmacies, and the growing role of registries of ABPM in many countries.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/métodos , Hipertensão/diagnóstico , Adolescente , Adulto , Idoso , Arritmias Cardíacas/complicações , Pressão Sanguínea/fisiologia , Monitorização Ambulatorial da Pressão Arterial/economia , Cardiologia/educação , Cardiologia/normas , Criança , Análise Custo-Benefício , Europa (Continente) , Feminino , Humanos , Nefropatias/complicações , Masculino , Obesidade/complicações , Guias de Prática Clínica como Assunto , Gravidez , Reprodutibilidade dos Testes , Sociedades Médicas , Hipertensão do Jaleco Branco
12.
Clinicoecon Outcomes Res ; 5: 317-25, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23882152

RESUMO

BACKGROUND: In SMILE-4 (the Survival of Myocardial Infarction Long-term Evaluation 4 study), zofenopril + acetylsalicylic acid (ASA) was superior to ramipril + ASA in reducing the occurrence of major cardiovascular events in patients with left ventricular dysfunction following acute myocardial infarction. The present post hoc analysis was performed to compare the cost-effectiveness of zofenopril and ramipril. METHODS: In total, 771 patients with left ventricular dysfunction and acute myocardial infarction were randomized in a double-blind manner to receive zofenopril 60 mg/day (n = 389) or ramipril 10 mg/day (n = 382) + ASA 100 mg/day and were followed up for one year. The primary study endpoint was the one-year combined occurrence of death or hospitalization for cardiovascular causes. The economic analysis was based on evaluation of cost of medications and hospitalizations and was applied to the intention-to-treat population (n = 716). Cost data were drawn from the National Health Service databases of the European countries participating in the study. The incremental cost-effectiveness ratio was used to quantify the cost per event prevented with zofenopril versus ramipril. RESULTS: Zofenopril significantly (P = 0.028) reduced the risk of the primary study endpoint by 30% as compared with ramipril (95% confidence interval, 4%-49%). The number needed to treat to prevent a major cardiovascular event with zofenopril was 13 less than with ramipril. The cost of drug therapies was higher with zofenopril (328.78 Euros per patient per year, n = 365) than with ramipril (165.12 Euros per patient per year, n = 351). The cost related to the occurrence of major cardiovascular events requiring hospitalization averaged 4983.64 Euros for zofenopril and 4850.01 Euros for ramipril. The incremental cost-effectiveness ratio for zofenopril versus ramipril was 2125.45 Euros per event prevented (worst and best case scenario in the sensitivity analysis was 3590.09 and 3243.96 Euros, respectively). CONCLUSION: Zofenopril is a viable and cost-effective treatment for managing patients with left ventricular dysfunction after acute myocardial infarction.

13.
Hypertens Res ; 36(9): 795-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23595046

RESUMO

An increased rate of cardiovascular and cerebrovascular events has been described during and immediately after earthquakes. In this regard, few data are available on long-term blood pressure control in hypertensive outpatients after an earthquake. We evaluated the long-term effects of the April 2009 L'Aquila earthquake on blood pressure levels, as detected by 24 h ambulatory blood pressure monitoring. Before/after (mean±s.d. 6.9±4.5/14.2±5.1 months, respectively) the earthquake, the available 24 h ambulatory blood pressure monitoring data for the same patients were extracted from our database. Quake-related daily life discomforts were evaluated through interviews. We enrolled 47 patients (25 female, age 52±14 years), divided into three groups according to antihypertensive therapy changes after versus before the earthquake: unchanged therapy (n=24), increased therapy (n=17) and reduced therapy (n=6). Compared with before the quake, in the unchanged therapy group marked increases in 24 h (P=0.004), daytime (P=0.01) and nighttime (P=0.02) systolic blood pressure were observed after the quake. Corresponding changes in 24 h (P=0.005), daytime (P=0.01) and nighttime (P=0.009) diastolic blood pressure were observed. Daily life discomforts were reported more frequently in the unchanged therapy and increased therapy groups than the reduced therapy group (P=0.025 and P=0.018, respectively). In conclusion, this study shows that patients with unchanged therapy display marked blood pressure increments up to more than 1 year after an earthquake, as well as long-term quake-related discomfort. Our data suggest that particular attention to blood pressure levels and adequate therapy modifications should be considered after an earthquake, not only early after the event but also months later.


Assuntos
Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/fisiologia , Terremotos , Hipertensão/fisiopatologia , Adulto , Idoso , Anti-Hipertensivos/farmacologia , Pressão Sanguínea/efeitos dos fármacos , Monitorização Ambulatorial da Pressão Arterial , Feminino , Humanos , Hipertensão/tratamento farmacológico , Itália , Masculino , Pessoa de Meia-Idade , Qualidade de Vida
14.
Trials ; 14: 22, 2013 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-23343138

RESUMO

BACKGROUND: Inadequate blood pressure control and poor adherence to treatment remain among the major limitations in the management of hypertensive patients, particularly of those at high risk of cardiovascular events. Preliminary evidence suggests that home blood pressure telemonitoring (HBPT) might help increasing the chance of achieving blood pressure targets and improve patient's therapeutic adherence. However, all these potential advantages of HBPT have not yet been fully investigated. METHODS/DESIGN: The purpose of this open label, parallel group, randomized, controlled study is to assess whether, in patients with high cardiovascular risk (treated or untreated essential arterial hypertension--both in the office and in ambulatory conditions over 24 h--and metabolic syndrome), long-term (48 weeks) blood pressure control is more effective when based on HBPT and on the feedback to patients by their doctor between visits, or when based exclusively on blood pressure determination during quarterly office visits (conventional management (CM)). A total of 252 patients will be enrolled and randomized to usual care (n = 84) or HBPT (n = 168). The primary study endpoint will be the rate of subjects achieving normal daytime ambulatory blood pressure targets (< 135/85 mmHg) 24 weeks and 48 weeks after randomization. In addition, the study will assess the psychological determinants of adherence and persistence to drug therapy, through specific psychological tests administered during the course of the study. Other secondary study endpoints will be related to the impact of HBPT on additional clinical and economic outcomes (number of additional medical visits, direct costs of patient management, number of antihypertensive drugs prescribed, level of cardiovascular risk, degree of target organ damage and rate of cardiovascular events, regression of the metabolic syndrome). DISCUSSION: The TELEBPMET Study will show whether HBPT is effective in improving blood pressure control and related medical and economic outcomes in hypertensive patients with metabolic syndrome. It will also provide a comprehensive understanding of the psychological determinants of medication adherence and blood pressure control of these patients. TRIAL REGISTRATION: Clinical Trials.gov: NCT01541566.


Assuntos
Protocolos Clínicos , Hipertensão/tratamento farmacológico , Adesão à Medicação , Síndrome Metabólica/fisiopatologia , Telemedicina , Monitorização Ambulatorial da Pressão Arterial , Humanos , Hipertensão/fisiopatologia , Hipertensão/psicologia , Avaliação de Resultados em Cuidados de Saúde
15.
J Hypertens ; 31(3): 455-67; discussion 467-8, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23299557

RESUMO

OBJECTIVE: To systematically review data from randomized controlled studies on the effectiveness of home blood pressure telemonitoring (HBPT) versus usual care with respect to improvement of BP control, healthcare resources utilization and costs, patient's quality of life and adverse events. METHODS: Electronic databases were searched for publications in English. The benefit and relative risk (RR) were estimated applying a random-effect model. RESULTS: Twenty-three randomized controlled trials with a high level of heterogeneity were selected (7037 patients). Compared to usual care, HBPT improved office SBP by 4.71 mmHg [95% confidence interval (CI): 6.18, 3.24; P < 0.001] and DBP by 2.45 mmHg (3.33, 1.57; P < 0.001). A larger proportion of patients achieved office BP normalization (<140/90 mmHg nondiabetic patients and <130/80 mmHg diabetic patients) in the intervention group [RR: 1.16 (1.04, 1.29); P < 0.001]. HBPT led to a significantly larger prescription of antihypertensive medications [+0.40 (+0.17,+0.62), P < 0.001], but to therapeutic adherence and rate of office consultations similar to usual care. Healthcare costs were significantly (P < 0.001) larger in the HBPT group [+662.92 (+540.81, +785.04) euros per patient], but were similar to those of the usual care when only medical costs were considered [-12.4 (-930.52, +906.23) euros; P = 0.767]. Use of HBPT helped improving the physical component of quality of life [SF-12 or SF-36 questionnaire: +2.78 (+1.15, +4.41) P < 0.001]. No difference was observed in the risk of adverse events [RR: 1.22 (0.86, 1.71); P = 0.111]. CONCLUSION: HBPT may represent a useful tool to improve hypertension control and associated healthcare outcomes, although it is still more costly compared with usual care.


Assuntos
Pressão Sanguínea , Serviços de Assistência Domiciliar , Monitorização Fisiológica/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Telemedicina , Humanos
16.
Blood Press Monit ; 15(6): 285-95, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21084882

RESUMO

Despite the increasing use of home blood pressure monitoring (HBPM) in daily practice and the growing awareness in the scientific community about its positive impact on the diagnostic and therapeutic management of patients with high blood pressure (BP), the potential advantages offered by HBPM have not yet been fully exploited. Indeed, use of the information offered by HBPM is often incomplete and imprecise, with the BP values reported by patients in handwritten logbooks being frequently inaccurate, illegible to physicians, or unreliable. Although a practical solution for improvement may come from the use of devices equipped with a storage memory, a step forward in this regard has been taken more recently with the introduction and refinement of systems for the remote telemonitoring of BP values measured at home. However, although several studies have provided evidence on the clinical usefulness of HBPM, only limited data are available on the clinical impact of home blood pressure (HBP) telemonitoring, because of a number of reasons. First, most of the available studies are characterized by a small sample size, and in some cases, the patients were neither randomized nor even matched with a control group. Moreover, technological solutions used in the different studies carried out so far are often heterogeneous, some of them being particularly difficult to use for the patients, thus limiting the effectiveness of the results. BP monitoring programmes, number of BP readings and transmission schedules are often different among the various studies. In addition, patient selection criteria are different from study to study. Finally, different study objectives and important diversities in the types of centres involved (ranging from general practices, to specialists' offices, hospitals or university centres) may have also influenced the quality of results. Large-scale randomized controlled studies, based on easy-to-use technologies, are thus still needed to show the superiority and clinical usefulness of HBP telemonitoring as compared with conventional HBPM. This study summarizes the evidence available on the clinical usefulness and current limitations of this approach, highlighting the results of meta-analyses and randomized controlled trials on this issue. The role of HBP teletransmission in the context of integrated patients' management programmes is also addressed, with indications for further progress in this field.


Assuntos
Monitorização Ambulatorial da Pressão Arterial/métodos , Hipertensão/tratamento farmacológico , Telemedicina/métodos , Determinação da Pressão Arterial , Monitorização Ambulatorial da Pressão Arterial/economia , Humanos , Metanálise como Assunto , Pessoa de Meia-Idade , Administração dos Cuidados ao Paciente , Cooperação do Paciente , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
J Hypertens ; 25(5): 1087-94, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17414674

RESUMO

OBJECTIVES: Information on the features of long-term modifications of clinic and 24-h ambulatory blood pressure (ABP) by treatment is limited. The present study aimed to address this issue. METHODS: Ambulatory BP monitoring and clinic BP (CBP) measurements were performed at baseline and at yearly intervals over a 4-year follow-up period in 1523 hypertensives (56.1 +/- 7.6 years) randomized to treatment with lacidipine or atenolol in the European Lacidipine Study on Atherosclerosis (ELSA). RESULTS: CBP was always greater than ABP, while reductions in all BP values (greater for CBP than for ABP) were on average maintained throughout 4 years, CBP changes showing limited relationship with ABP changes (r = 0.14-0.27). BP reductions by treatment during daytime and night-time were correlated (r = 0.63-0.73). BP normalization was achieved in a greater percentage of patients for CBP (41.7%) than for ABP (25.3%), with systolic BP control being always less common than diastolic BP control. BP normalization was more frequent at single yearly visits than throughout the 4 years. Twenty-four-hour BP variability was reduced by treatment over 4 years in absolute but not in normalized units. CONCLUSIONS: The present study provides the best evidence available on long-term effect of antihypertensive treatment on both ABP and CBP. On average, ABP was sustainedly reduced by treatment throughout the follow-up period, but 24-h BP was more difficult to control than CBP. In several patients, ABP control was unstable between visits, the percentage of patients under control over 4 years being much less than that of those controlled at each year. Treatment induced a reduction in absolute but not in normalized BP variability estimates. This has clinical implications because of the prognostic importance of ABP mean values and variability.


Assuntos
Anti-Hipertensivos/uso terapêutico , Atenolol/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Di-Hidropiridinas/uso terapêutico , Hipertensão/tratamento farmacológico , Anti-Hipertensivos/farmacologia , Atenolol/farmacologia , Aterosclerose/tratamento farmacológico , Monitorização Ambulatorial da Pressão Arterial , Di-Hidropiridinas/farmacologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA