Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Clin Radiol ; 67(3): 224-31, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21944774

RESUMO

AIM: To evaluate multi-detector computed tomography (MDCT) findings of intraductal papillary neoplasm of the bile duct (IPNB), a neoplasm that is considered to be the biliary counterpart of pancreatic intraductal papillary mucinous neoplasm. MATERIALS AND METHODS: Two radiologists retrospectively evaluated multiphase contrast-enhanced CT images with 0.5 or 1mm collimation in 37 consecutive patients with resected IPNB diagnosed by a single pathologist. The CT findings were correlated with the pathological findings concerning invasion of the surrounding organs and vessels. RESULTS: All patients showed bile duct dilatation. An intraductal mass was detected in 36 patients and the following findings were observed: extensive infiltration along the bile duct more than 20mm (n=32), compared with normal hepatic parenchyma, isodense or hyperdense during the late arterial phase (n=31), not hyperdense during the portal-venous and delayed phases (n=36), and intense enhancement rim at the base of the mass during the portal-venous or delayed phase (n=27). Parenchymal invasion of the surrounding organs was seen in eight of 16 tumours showing irregular or bulging margins. Vascular invasion was false positive in four of eight tumours. CONCLUSIONS: IPNB exhibits relatively characteristic findings with multiphase contrast-enhanced examination using MDCT. A tendency to overestimate invasion of the surrounding organs and vessels was seen.


Assuntos
Adenocarcinoma Mucinoso/diagnóstico por imagem , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Carcinoma Papilar/diagnóstico por imagem , Colangiocarcinoma/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Dilatação Patológica/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Clin Radiol ; 65(9): 735-43, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20696301

RESUMO

AIM: To assess the spectrum of findings using multiphase contrast-enhanced computed tomography (CT) in patients with autoimmune pancreatitis (AIP). MATERIALS AND METHODS: Fifty patients (four female and 46 male, mean age 65 years) were retrospectively identified from consecutive patients with abnormal CT findings of the pancreas and negative work-up for known causes. These patients had at least one finding supporting the diagnosis of AIP: serological abnormality, histopathological abnormality, or response to steroid. Two radiologists evaluated multiphase contrast-enhanced CT images in consensus. RESULTS: The pancreas showed diffuse enlargement (n=16; 32%), focal enlargement (n=18; 36%), or no enlargement (n=16; 32%). Forty-nine (98%) patients showed abnormal contrast enhancement in the affected pancreatic parenchyma, including hypoattenuation during the pancreatic phase (n=45; 90%) and hyperattenuation during the delayed phase (n=39; 87%). The following findings were also seen in the pancreas: a capsule-like rim (n=24; 48%); no visualization of the main pancreatic duct lumen (n=48; 96%); ductal enhancement (n=26; 52%); upstream dilatation of the main pancreatic duct (n=27; 54%); upstream atrophy of the pancreatic parenchyma (n=27; 54%); calcification (n=7; 14%); and cysts (n=5; 10%). Forty-two (84%) patients showed one or more of the following extrapancreatic findings: biliary duct or gallbladder abnormality (n=40; 80%); peripancreatic (n=8; 16%) or para-aortic (n=10; 20%) soft-tissue proliferation; and renal involvement (n=15; 30%). CONCLUSION: Patients with AIP presented with a variety of CT findings in the pancreas and the extrapancreatic organs. The present study highlights pancreatic ductal enhancement in a subset of patients with AIP.


Assuntos
Doenças Autoimunes/diagnóstico por imagem , Meios de Contraste , Pancreatite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Doenças Autoimunes/patologia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia , Pancreatite/patologia , Estudos Retrospectivos
3.
Clin Radiol ; 64(11): 1104-14, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19822244

RESUMO

AIM: To assess the clinical, computed tomography (CT), and pathological findings in patients with lymphoplasmacytic sclerosing cholangitis. MATERIALS AND METHODS: Fifteen consecutive patients (four women and 11 men, mean age 71 years) with lymphoplasmacytic sclerosing cholangitis and without the characteristic features of underlying disorders causing benign biliary strictures were retrospectively recruited. Two radiologists evaluated multiphase contrast-enhanced CT images acquired with 0.5 or 1-mm collimation. One pathologist performed all histological examinations, including IgG4 immunostaining. RESULTS: The intrahepatic biliary ducts showed dilatation in all 15 patients, but only seven presented with jaundice. Although laboratory data were not available in all patients, serum gammaglobulin and IgG levels were elevated in five of six patients and six of eight patients, respectively. Anti-nuclear antibody was detected in three of six patients. The involved biliary ducts showed the following CT findings: involvement of the hilar biliary duct (14/15), a mean wall thickness of 4.9 mm, a smooth margin (10/15), a narrow but visible lumen (6/15), hyper-attenuation during the late arterial phase (9/15), homogeneous hyper-attenuation during the delayed phase (11/11), and no vascular invasion (14/15). Abnormal findings in the pancreas and urinary tract were detected in eight of 15 patients. In 13 patients with adequate specimens, moderate to severe lymphoplasmacytic infiltration associated with dense fibrosis was observed. Infiltration of IgG4-positive plasma cells was moderate or severe in nine patients and minimal or absent in four patients. CONCLUSION: Lymphoplasmacytic sclerosing cholangitis exhibits relatively characteristic clinical and CT findings, although they are not sufficiently specific for differentiation from other biliary diseases.


Assuntos
Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Colangite Esclerosante/diagnóstico por imagem , Idoso , Fosfatase Alcalina/sangue , Anticorpos Antinucleares/sangue , Colangite Esclerosante/patologia , Meios de Contraste , Feminino , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , gama-Globulinas/análise
4.
J Cardiol ; 37 Suppl 1: 93-101, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11433835

RESUMO

BACKGROUND: A novel imaging system has been introduced which uses a dedicated two-dimensional echo probe for rapid beam forming to scan a pyramidal volume in real time. Real-time volumetric echocardiography has the potential to determine accurate cardiovascular anatomy, volume and function in the beating heart without reconstructions. The results of animal and human studies using volumetric echocardiography are evaluated for the potential for clinical applications. IMAGING METHODOLOGY: A new type of ultrasound imaging, high-speed volumetric scanning based on phased array principles permits real-time three-dimensional, volumetric echocardiography (real-time 3-DE). The system requires no off-line reconstruction techniques, thus enabling dynamic three-dimensional visualization and quantification of the heart in real time using a transthoracic approach. Real-time 3-DE uses a 2-D matrix phased array transducer. Image formation employs 16:1 parallel processing to scan a pyramidal volume composed of multiple steering directions in the azimuth dimension and in the elevation dimension. The finished transducer is mounted in a hand-held case with a circular aperture of 16 mm diameter. The array consists of approximately 1,600 elements, operating at 2.5 MHz. Real-time 3-DE permits simultaneous, multiple plane display of two sector arcs (B-scans) and C-scan (parallel to the transducer face or inclined) on a single monitor, conveying the three-dimensional nature of the ultrasound data. This system also allows these planes to be angled for extra diagnostic flexibility. The motion of all the structures during the cardiac cycle can be evaluated in dynamic mode. METHODS: Real-time 3-DE was assessed for accuracy of volume measurement by measuring the volume of balloons of different size and shape, and the hearts of 15 closed chest dogs with myocardial contrast enhancement, and compared to the volumes measured by left ventricular angiography in the dogs. Real-time 3-DE was used to evaluate the endocardial border determination of the entire left ventricle by injecting contrast agent in 12 patients. The endocardial border determination of each segment was scored, and the endocardial border score index calculated. Both real-time 3-D images and cine magnetic resonance imaging (MRI) were performed in 16 patients to assess the accuracy of volume measurement of the left ventricle in humans. The endocardial border of the left ventricle was manually traced, and the volumes calculated by Simpson's rule. RESULTS: The volumes measured by real-time 3-DE correlated well with the true volumes for different sizes of balloon and for asymmetric balloons. The end-diastolic volume and end-systolic volume linear correlation of real-time 3-DE versus angiography measurements using manual tracing in vivo also gave a good correlation (r = 0.97, p < 0.001; r = 0.92, p < 0.01). Fifty-eight of 192 segments were rated as good at baseline and 143 rated as good after Levovist injection. Endocardial border determination was improved by Levovist injection in 100 of 137 segments (74.6%). The endocardial border score index was significantly higher after Levovist administration than at baseline (p < 0.003). The end-diastolic volume and end-systolic volume of the left ventricle measured by real-time 3-DE in humans correlated well with those measured by MRI (end-diastolic volume: r = 0.97, p < 0.001; end-systolic volume: r = 0.96, p < 0.001). CONCLUSIONS: Transthoracic real-time, volumetric echocardiography opens a new and exciting field of echocardiography. The results of these studies demonstrate that this system can accurately measure the ventricular volume and function without use of geometric assumptions. This volumetric mode or V-mode scanning is a new imaging modality that provides a practical methodology to investigate important clinical and research questions.


Assuntos
Volume Cardíaco/fisiologia , Doença das Coronárias/diagnóstico por imagem , Ecocardiografia/métodos , Coração/fisiologia , Animais , Doença das Coronárias/fisiopatologia , Cães , Ecocardiografia/normas , Ecocardiografia Tridimensional , Humanos , Imagens de Fantasmas , Função Ventricular Esquerda
5.
J Cereb Blood Flow Metab ; 21(3): 295-306, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11295884

RESUMO

N-[11C]methylpiperidin-4-yl acetate ([11C]MP4A) is a radiotracer that has been used successfully for the quantitative measurement of acetylcholinesterase (AChE) activity in the human brain with positron emission tomography (PET) using a standard compartment model analysis and a metabolite-corrected arterial input function. In the current study, the authors evaluated the applicability of a simple kinetic analysis without blood sampling, namely shape analysis. First, the authors used computer simulations to analyze factors that affect the precision and bias of shape analysis, then optimized the shape analysis procedure for [11C]MP4A. Before shape analysis execution, the later part of dynamic PET data except for the initial 3 minutes were smoothed by fitting to a bi-exponential function followed by linear interpolation of 8 data points between each of adjacent scan frames. Simulations showed that shape analysis yielded estimates of regional metabolic rates of [11C]MP4A by AChE (k3) with acceptable precision and bias in brain regions with low k3 values such as neocortex. Estimates in regions with higher k3 values became progressively more inaccurate. The authors then applied the method to [11C]MP4A PET data in 10 healthy subjects and 20 patients with Alzheimer's disease (AD). There was a highly significant linear correlation in regional k3 estimates between shape and compartment analyses (300 neocortical regions, [shape k3] = 0.93 x [NLS k3], r = 0.89, P < 0.001). Significant reductions in k3 estimates of frontal, temporal, parietal, occipital, and sensorimotor cerebral cortices in patients with AD as compared with controls were observed when using shape analysis (P < 0.013, two-tailed t-test), although these reductions (17% to 20%) were somewhat less than those obtained by compartment analysis (22% to 27%). The sensitivity of shape analysis for detecting neocortical regions with abnormally low k3 in the 20 patients with AD (92 out of 200 regions, 46%) also was somewhat less than compartment analysis (136 out of 200 regions, 68%). However, taking its simplicity and noninvasiveness into account, the authors conclude that quantitative measurement of neocortical AChE activity with shape analysis and [11C]MP4A PET is practical and useful for clinical diagnosis of AD.


Assuntos
Acetatos , Acetilcolinesterase/metabolismo , Doença de Alzheimer/diagnóstico por imagem , Piperidinas , Tomografia Computadorizada de Emissão/métodos , Idoso , Doença de Alzheimer/metabolismo , Artérias , Coleta de Amostras Sanguíneas , Encéfalo/enzimologia , Radioisótopos de Carbono , Humanos , Pessoa de Meia-Idade , Método de Monte Carlo
6.
J Am Soc Echocardiogr ; 14(4): 275-84, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11287890

RESUMO

Quantitative assessment of left ventricular ejection fraction is an essential component of cardiac evaluation. We performed real-time 3-dimensional echocardiography in 56 consecutive patients who underwent multigated radionuclide angiography. Thirteen patients were excluded for the following reasons: 5 for large size of left ventricle required for image acquisition, 5 for suboptimal image quality in real-time 3-dimensional echocardiography, and 3 for atrial fibrillation. Finally, we compared left ventricular ejection fraction assessed by real-time 3-dimensional echocardiography and conventional 2-dimensional echocardiography with that obtained by multigated radionuclide angiography in 43 patients. Left ventricular ejection fraction was determined by real-time 3-dimensional echocardiography with the use of parallel plane-disks and sector plane-disks summation methods. A good correlation was obtained between both real-time 3-dimensional echocardiography methods and multigated radionuclide angiography (r = 0.87 and 0.90, standard error of estimate = 3.7% and 4.2%), whereas the relation between the 2-dimensional echocardiography method and radionuclide angiography demonstrated a significant departure from the line of identity (P <.001). In addition, interobserver variability was significantly lower (P <.05) for the real-time 3-dimensional echocardiography methods than that by the 2-dimensional echocardiography method. Real-time 3-dimensional echocardiography may be used for quantification of left ventricular function as an alternative to conventional methods in patients with adequate image quality.


Assuntos
Ecocardiografia Tridimensional , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Angiografia Coronária , Ecocardiografia , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Angiografia Cintilográfica
7.
J Am Soc Echocardiogr ; 12(4): 241-51, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10196501

RESUMO

Intraoperative color Doppler transesophageal echocardiography with a 4- to 7-MHz transducer was performed on 28 consecutive patients who underwent coronary artery bypass grafting to image and evaluate the transmural coronary blood flow before and after cardiopulmonary bypass. The transmural coronary flow was visualized in 26 (92.8%) of 28 patients in the inferior wall and in 13 (46.4%) of 28 patients in the lateral wall. The peak diastolic flow velocity of the transmural coronary artery in the inferior and lateral wall was significantly increased after coronary revascularization in patients with a successful bypass graft to the right coronary artery (from 34.0 +/- 19.7 to 64.9 +/- 30.9 cm/s, P <.001, n = 10) and to the left circumflex coronary artery (from 35.1 +/- 18.6 to 62.1 +/- 21.1 cm/s, P <.001, n = 10). No significant changes were observed in patients with no bypass graft to the right or left circumflex coronary artery. Coronary blood flow can be mapped and the velocity measured with Doppler transesophageal echocardiography with a high-frequency (4- to 7-MHz) transducer. Assessment of the transmural coronary flow may provide valuable information and aid in decision making during surgical revascularization.


Assuntos
Ponte de Artéria Coronária , Circulação Coronária/fisiologia , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Cuidados Intraoperatórios , Ultrassonografia de Intervenção , Adulto , Idoso , Angina Instável/cirurgia , Velocidade do Fluxo Sanguíneo , Ponte Cardiopulmonar , Doença das Coronárias/cirurgia , Vasos Coronários/diagnóstico por imagem , Tomada de Decisões , Diástole , Ecocardiografia Doppler em Cores/instrumentação , Ecocardiografia Transesofagiana/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Transdutores , Ultrassonografia de Intervenção/instrumentação
8.
J Am Soc Echocardiogr ; 12(1): 7-14, 1999 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9882773

RESUMO

Accurate characterization of regional wall motion abnormalities requires a thorough evaluation of the entire left ventricle (LV). Although 2-dimensional echocardiography is frequently used for this purpose, the inability of tomographic techniques to record the complete endocardial surface is a limitation. Three-dimensional echocardiography, with real-time volumetric imaging, has the potential to overcome this limitation by capturing the entire volume of the LV and displaying it in a cineloop mode. The purpose of this study was to assess the feasibility of using real-time 3-dimensional (RT3D) echocardiography to detect regional wall motion abnormalities in patients with abnormal LV function and to develop a scheme for the systematic evaluation of wall motion by using the 3-dimensional data set. Twenty-six patients with high-quality 2-dimensional echo images and at least 1 regional wall motion abnormality were examined with RT3D echocardiography. For 2-dimensional echocardiography, wall motion was analyzed with a 16-segment model and graded on a 4-point scale from normal (1) to dyskinetic (4), from which a wall motion score index was calculated. Individual segments were then grouped into regions (anterior, inferoposterior, lateral, and apical) and the number of regional wall motion abnormalities was determined. The RT3D echocardiogram was recorded as a volumetric, pyramid-shaped data set that contained the entire LV. Digital images, consisting of a single cardiac cycle cineloop, were analyzed off-line with a computerized display of the apical projection. Two intersecting orthogonal apical projections were simultaneously displayed in cineloop mode, each independently tilted to optimize orientation and endocardial definition. The 2 planes were then slowly rotated about the major axis to visualize the entire LV endocardium. Wall motion was then graded in 6 equally spaced views, separated by 30 degrees, yielding 36 segments per patient. A higher percentage of segments were visualized with 2-dimensional versus RT3D echocardiography (97% vs 83%, respectively, P <.001). With the use of the 2-dimensional echocardiographic results as the standard, RT3D echocardiography detected 55 (96%) of 57 regional wall motion abnormalities. Analysis of the RT3D echocardiograms resulted in 3 false-negative and 5 false-positive findings. The total number of regional wall motion abnormalities was correctly classified by RT3D echocardiography in 19 (73%) of 26 patients. RT3D echocardiography detected 11 of 13 anterior, 19 of 20 inferoposterior, 9 of 9 lateral, and 15 of 15 apical wall motion abnormalities. An excellent correlation was found between the 2 techniques for assessment of the regional wall motion score index (r = 0.89, P <.001). This initial clinical study demonstrates the feasibility and potential advantages of RT3D echocardiography for the assessment of regional LV function. Compared with 2-dimensional echocardiography, this new method permits recording of the entire LV in a single beat, allowing the extent and location of the regional wall motion abnormalities to be determined.


Assuntos
Ecocardiografia Tridimensional/métodos , Coração/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Cardiomiopatia Dilatada/diagnóstico por imagem , Apresentação de Dados , Ecocardiografia , Endocárdio/diagnóstico por imagem , Reações Falso-Negativas , Reações Falso-Positivas , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Contração Miocárdica/fisiologia , Infarto do Miocárdio/diagnóstico por imagem , Isquemia Miocárdica/diagnóstico por imagem , Rotação , Disfunção Ventricular Esquerda/classificação
9.
J Bone Miner Metab ; 17(3): 195-200, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10757679

RESUMO

This study investigated the role of quantitative ultrasound (QUS) for evaluation of fracture risk in comparison with bone mineral density (BMD) measurement. Our subjects were postmenopausal Japanese women (n = 260; age, 67 +/- 6.1 years) who were examined for bone densitometry, QUS, and spinal X-ray examination at our department between 1992 and 1996. The subjects were categorized into three groups by the number of atraumatic fractured vertebrae: NF, no vertebral fractures: F1, one vertebral fracture; F2, two or more vertebral fractures. We compared the measured parameters to determine their association with the number of fractured vertebrae. Differences among groups were compared and analyzed by Student's t-test. Odds ratios were also calculated after age adjustment, as well as age and lumbar or calcaneal parameters. Between NF and F1, lumbar BMD and BMD of the Ward's triangle showed more significant differences than other values, while between F1 and F2, whole-body BMD and QUS parameters showed more significant differences. Lumbar BMD also showed the highest age-adjusted odds ratio in differentiating F1 from NF. Although QUS parameters showed no power to differentiate between NF and F1, these values showed higher odds ratios than other measurements for discriminating between F1 and F2. Adjustment for bone density did not totally abolish the association between QUS parameters and vertebral fracture. Additionally, the combination of lumbar BMD and QUS ("stiffness") clearly showed a high power to discriminate NF from F1 + F2. In conclusion, we showed that QUS measurement is effective in evaluating fracture risk in advanced osteoporosis, while lumbar dual X-ray absorptiometry is effective in evaluating risk in early osteoporosis.


Assuntos
Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Feminino , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/fisiopatologia , Humanos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/fisiopatologia , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia
10.
Spinal Cord ; 34(9): 531-5, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8883187

RESUMO

There is some information about the Functional Independence Measure (FIM) score of patients with spinal cord injury (SCI), but there are a few publications dealing with the relationship between the FIM score and the motor score of the American Spinal Injury Association (ASIA). We have studied the relationship of all FIM items with the motor score, and reviewed the disability of patients with spinal cord injury in greater detail. The purpose of this study was to describe the characteristics of impairment and disability in patients with SCI, using the FIM and motor score of the ASIA. The subjects were 100 inpatients with SCI (Frankel A, B). Neurological level, days from the onset, and the FIM were examined. In addition to these items, the ASIA motor scores were calculated for 22 tetraplegic patients. We investigated the relationships among these various respects. We also examined the changes of the physical items of the FIM score (physical FIM) over time for 18 patients. The mean FIM scores of those with tetraplegia with C4, C5, C6, C7, C8 lesions, and those with paraplegia with above T5 levels, and those below T6 were 35, 61, 82, 90, 116, 114 and 114 respectively. The FIM score reached the plateau in approximately 10 months, 6 months and 3 months post-injury, in tetraplegia, paraplegia above T5 and that below T6 respectively. The FIM scores in C6 patients were widely distributed from 56 to 104. On the other hand, the ASIA motor score could subdivide C6 patients and related well to the FIM score. The mean FIM scores for each neurological level were similar to those previously reported, thus they appeared to be plateau scores. With regard to the motor score, we feel that it could reflect the disability of the patients better than considering the neurological levels alone. Also considering the changes in the physical FIM score over time within a year from the onset of the injury, there were differences in the ADL improvement patterns among patients with different neurological levels. It appears that timing of the highest physical FIM improvement for each neurological level can exist. Thus it is important not to delay the start of the rehabilitation of patients with spinal cord injury in proper time.


Assuntos
Avaliação da Deficiência , Traumatismos da Medula Espinal/fisiopatologia , Atividades Cotidianas , Humanos , Exame Neurológico , Paraplegia/fisiopatologia , Paraplegia/reabilitação , Quadriplegia/fisiopatologia , Quadriplegia/reabilitação , Traumatismos da Medula Espinal/reabilitação , Fatores de Tempo
11.
J Cardiol ; 22(2-3): 447-55, 1992.
Artigo em Japonês | MEDLINE | ID: mdl-1339803

RESUMO

The diagnostic value of preoperative echocardiography was assessed in 51 patients with aortic stenosis. We measured 1) left ventricular-aortic pressure gradient (LV-Ao PG), 2) aortic valve area (AVA), 3) grade of LV hypertrophy and function, and 4) aortic annulus diameter for determining the availability and size of a prosthesis. The maximal instantaneous PG (max-PG) by continuous-wave (cw) Doppler echocardiography correlated well with the peak-to-peak PG by cardiac catheterization (cath), and their correlation equation was y = 1.49 x -48.3 with a correlation coefficient of 0.90. Excellent correlations were also found between cw-max PG and cath-max PG (r = 0.84), and between cw-mean systolic PG and cath-mean systolic PG (r = 0.80). The AVA of the echocardiogram, which was derived from the stroke volume using Gibson's M-mode echocardiographic formula and the cw-Doppler echocardiographic mean gradient, correlated well with the AVA of the cardiac catheterization using Gorlin's formula (y = 1.33 x -0.61, r = 0.79). Preoperative LV pump function, which was obtained from the M-mode echocardiogram, correlated inversely with end-systolic wall stress, and a depressed LV pump function was observed in patients with inadequate hypertrophy. In such patients, however, depressed function was alleviated after surgical treatment. Thus, we considered that cardiac catheterization for further examination is unnecessary, even in such patients. To determine the available size of the prosthesis, measurement of the inner diameter of the aortic annulus on the long-axis cross-sections was the most useful.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Estenose da Valva Aórtica/cirurgia , Adulto , Idoso , Aorta/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Pressão Sanguínea , Ecocardiografia , Ecocardiografia Doppler , Feminino , Próteses Valvulares Cardíacas , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Função Ventricular Esquerda , Pressão Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA