Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 103(4): 670-677, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38363043

RESUMO

BACKGROUND: Nicorandil is widely used as a vasodilator for the physiological assessment of coronary arteries because of its usefulness and safety; however, there are no data on its use in peripheral arteries. AIMS: To identify the utility of nicorandil and its appropriate dose for the physiological assessment on the femoropopliteal artery. METHODS: We retrospectively enrolled patients from three institutes in which physiological assessment was carried out with various doses of nicorandil before treatment. Twenty-four femoropopliteal artery stenotic lesions from 22 patients were included. The nicorandil doses used were 2, 4, and 6 mg. Twenty-two lesions were also assessed using 30 mg of papaverine. The pressure gradient (PG) and peripheral fractional flow reserve (pFFR) were calculated based on the mean and systolic pressure levels. We examined the correlation of each parameter with the peak systolic velocity ratio (PSVR) based on the duplex ultrasound images using Spearman's rank correlation coefficient. Systemic blood pressure was assessed for safety. RESULTS: The correlations were higher for mean pressure-based parameters than for systolic pressure-based parameters. As the nicorandil dose increased, the correlations among PG, pFFR, and PSVR also increased (mean pressure-based PG: 2 mg, r = 0.360; 4 mg, r = 0.498; 6 mg, r = 0.694, mean pressure-based pFFR: 2 mg, r = -0.479; 4 mg, r = -0.469; 6 mg, r = -0.641). The blood pressure after the administration of 6 mg of nicorandil was low, and the median systemic mean pressure was 65 mmHg. CONCLUSION: A 4 mg dose of nicorandil is effective and safe for the mean pressure-based physiological assessment of lesions in the femoropopliteal artery.


Assuntos
Reserva Fracionada de Fluxo Miocárdico , Nicorandil , Humanos , Nicorandil/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Vasodilatadores/efeitos adversos , Vasos Coronários
2.
IEEE Trans Med Imaging ; 37(7): 1618-1625, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29969412

RESUMO

Intravascular polarimetry with polarization sensitive optical frequency domain imaging (PS-OFDI) measures polarization properties of the vessel wall and offers characterization of coronary atherosclerotic lesions beyond the cross-sectional image of arterial microstructure available to conventional OFDI. A previous study of intravascular polarimetry in cadaveric human coronary arteries found that tissue birefringence and depolarization provide valuable insight into key features of atherosclerotic plaques. In addition to various tissue components, catheter and sample motion can also influence the polarization of near infrared light as used by PS-OFDI. This paper aimed to evaluate the robustness and repeatability of imaging tissue birefringence and depolarization in a clinical setting. 30 patients scheduled for percutaneous coronary intervention at the Erasmus Medical Center underwent repeated PS-OFDI pullback imaging, using commercial imaging catheters in combination with a custom-built PS-OFDI console. We identified 274 matching cross sections among the repeat pullbacks to evaluate the reproducibility of the conventional backscatter intensity, the birefringence, and the depolarization signals at each spatial location across the vessel wall. Bland-Altman analysis revealed best agreement for the birefringence measurements, followed by backscatter intensity, and depolarization, when limiting the analysis to areas of meaningful birefringence. Pearson correlation analysis confirmed highest correlation for birefringence (0.86), preceding backscatter intensity (0.83), and depolarization (0.78). Our results demonstrate that intravascular polarimetry generates robust maps of tissue birefringence and depolarization in a clinical setting. This outcome motivates the use of intravascular polarimetry for future clinical studies that investigate polarization properties of arterial atherosclerosis.


Assuntos
Procedimentos Endovasculares/métodos , Imagem Óptica/métodos , Birrefringência , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Placa Aterosclerótica/diagnóstico por imagem , Reprodutibilidade dos Testes
3.
Hypertens Res ; 37(11): 1014-20, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25007768

RESUMO

Arterial stiffness is a significant predictor of cardiovascular disease (CVD), the risk of which is modified by medications for atherosclerotic risk factors and life-style changes. Cardio-ankle vascular index (CAVI) provides noninvasive, objective information on arterial stiffness, independent of blood pressure. This study aimed to investigate changes in CAVI after management of atherosclerotic risk factors, and the impact of these changes on future CVD outcomes in patients with coronary artery disease (CAD). The study consisted of 211 CAD patients (65 ± 10 years, 118 men) with impaired CAVI. CAVI examination was repeated 6 months later. Impaired CAVI was defined as greater than the mean plus 1 s.d. of the age- and gender-specific normal CAVI values, according to results obtained in 5188 healthy subjects. All patients were followed for > 1 year or until the occurrence of a CVD event. Of the 211 patients, CAVI improved in 106 (50%) patients after 6 months, but remained high in 105 (50%) patients. During follow-up (2.9 ± 1.0 years), CVD events occurred in 28 (13%) patients. Persistently impaired CAVI was an independent predictor of future CVD events (P = 0.01), independent of baseline CAVI. CVD outcomes were worse in patients with persistently impaired CAVI than in those with improved CAVI (P < 0.001). Among patients with a normalized CAVI after treatment (n = 22) only one suffered a CVD event. This study was the first to demonstrate that persistent impairment of arterial stiffness was an independent risk factor of future CVD events. Serial measurements of CAVI provide important prognostic information regarding patients with CAD in clinical practice.


Assuntos
Doenças Cardiovasculares/etiologia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/fisiopatologia , Rigidez Vascular , Adulto , Idoso , Índice Tornozelo-Braço , Aterosclerose/fisiopatologia , Pressão Sanguínea , Espessura Intima-Media Carotídea , Angiografia Coronária , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Fatores de Risco
4.
Hypertens Res ; 36(8): 691-7, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23595043

RESUMO

The accuracy of measurements of the intima-media thickness (IMT) and flow-mediated dilatation (FMD) of the brachial artery made using a new semiautomated ultrasound system and the relationships among those parameters and the Framingham Risk Score (FRS) as a predictor of coronary heart disease (CHD) are unknown. We enrolled 70 subjects, including 47 patients with cardiovascular risk factors and 23 normal healthy volunteers. IMT and FMD were simultaneously measured using a new semiautomated ultrasound system, and the measurements were compared with those obtained manually as a reference standard (study 1). In addition, we enrolled 200 consecutive patients with risk factors but no CHD to examine the relationships among IMT, FMD and the FRS. The optimal cutoff values of FMD and IMT were determined in 200 patients without CHD, and the subjects were classified into four groups. The 10-year Framingham risks for each group were compared (study 2). FMD and IMT measurements made using the new semiautomated ultrasound system showed a good correlation with the measurements determined manually (study 1). Furthermore, FMD and IMT showed a significant correlation with the FRS. The 10-year Framingham risk was markedly higher in group D (FMD <5.5% and IMT >0.3 mm; 19.0±11.3%; study 2). In conclusion, the measurements made using a new semiautomated ultrasound system provided reliable and simultaneous evaluations of IMT and FMD. The combination of IMT and FMD measurements of the brachial artery may be beneficial for risk stratification of patients with cardiovascular risk factors but no CHD.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Artéria Braquial/diagnóstico por imagem , Doenças Cardiovasculares/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Endotélio Vascular/diagnóstico por imagem , Adulto , Idoso , Artéria Braquial/fisiopatologia , Doenças Cardiovasculares/fisiopatologia , Doença das Coronárias/fisiopatologia , Endotélio Vascular/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/fisiopatologia , Túnica Média/diagnóstico por imagem , Túnica Média/fisiopatologia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA