Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
East Mediterr Health J ; 26(5): 616-619, 2020 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-32538457

RESUMO

BACKGROUND: Arboviruses such as dengue virus, yellow fever virus, Zika virus and chikungunya virus are major threats to human health globally, including countries in the Eastern Mediterranean Region (EMR). AIMS: This study aimed to assess laboratory proficiency in EMR countries for detection of dengue virus, yellow fever virus, Zika virus and chikungunya virus. METHODS: A global external quality assessment programme for arbovirus diagnostics was developed and run in 2016 and 2018. National-level public health laboratories were instructed to apply the polymerase chain reaction detection method on specimen panels containing dengue virus, yellow fever virus, Zika virus and chikungunya virus. RESULTS: Over both rounds of the programme, 100% of participating EMR laboratories correctly detected yellow fever virus and chikungunya virus, ≥ 84.6% detected dengue fever virus and ≥ 76.9% detected Zika virus. CONCLUSION: While participating EMR countries demonstrated good proficiency in detecting arboviruses, only half of them were enrolled in the global external quality assessment programme, providing an incomplete picture of regional capacity. Effort should be put into increasing participation in subsequent rounds.


Assuntos
Infecções por Arbovirus/diagnóstico , Arbovírus , Laboratórios/normas , Garantia da Qualidade dos Cuidados de Saúde/normas , Infecção por Zika virus , Febre de Chikungunya/diagnóstico , Dengue/diagnóstico , Humanos , Laboratórios/estatística & dados numéricos , Oriente Médio , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Organização Mundial da Saúde/organização & administração , Febre Amarela/diagnóstico , Infecção por Zika virus/diagnóstico
2.
Trop Med Infect Dis ; 4(4)2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-31847247

RESUMO

Background: In 2002, the World Health Organization (WHO) launched a regional microbiology external quality assessment (EQA) programme for national public health laboratories in the African region, initially targeting priority epidemic-prone bacterial diseases, and later including other common bacterial pathogens. Objectives: The aim of this study was to analyse the efficacy of an EQA programme as a laboratory quality system evaluation tool. Methods: We analysed the proficiency of laboratories' performance of bacterial identification and antimicrobial susceptibility testing (AST) for the period 2011-2016. The National Institute for Communicable Diseases of South Africa provided technical coordination following an agreement with WHO, and supplied EQA samples of selected bacterial organisms for microscopy (Gram stain), identification, and antimicrobial susceptibility testing (AST). National public health laboratories, as well as laboratories involved in the Invasive Bacterial Diseases Surveillance Network, were enrolled by the WHO Regional Office for Africa to participate in the EQA programme. We analysed participants' results of 41 surveys, which included the following organisms sent as challenges: Streptococcus pneumonia, Haemophilus influenzae, Neisseria meningitidis, Salmonella Typhi, Salmonella Enteritidis, Shigella flexneri, Staphylococcus aureus, Streptococcus agalactiae, Streptococcus anginosus, Enterococcus faecium, Serratia marcescens, Acinetobacter baumannii, and Enterobacter cloacae. Results: Eighty-one laboratories from 45 countries participated. Overall, 76% of participants obtained acceptable scores for identification, but a substantial proportion of AST scores were not in the acceptable range. Of 663 assessed AST responses, only 42% had acceptable scores. Conclusion: In the African Region, implementation of diagnostic stewardship in clinical bacteriology is generally suboptimal. This report illustrates that AST is poorly done compared to microscopy and identification. It is critically important to make the case for implementation of quality assurance in AST, as it is the cornerstone of antimicrobial resistance surveillance reporting and implementation of the Global Antimicrobial Resistance Surveillance System.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA