Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Autoimmun Rev ; 19(3): 102458, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31927087

RESUMO

Capillaroscopy is a non-invasive and safe tool which allows the evaluation of the morphology of the microcirculation. Since its recent incorporation in the 2013 American College of Rheumatology (ACR)/European League Against Rheumatism (EULAR) classification criteria for systemic sclerosis together with its assessed role to monitor disease progression, capillaroscopy became a 'mainstream' investigation for rheumatologists. Given its increasing use by a variety of physicians internationally both in daily practice to differentiate primary from secondary Raynaud's phenomenon, as well as in research context to predict disease progression and monitor treatment effects, standardisation in capillaroscopic image acquisition and analysis seems paramount. To step forward to this need, experts in the field of capillaroscopy/microcirculation provide in this very consensus paper their view on image acquisition and analysis, different capillaroscopic techniques, normal and abnormal capillaroscopic characteristics and their meaning, scoring systems and reliability of image acquisition and interpretation.


Assuntos
Angioscopia Microscópica , Unhas/irrigação sanguínea , Doença de Raynaud/diagnóstico , Escleroderma Sistêmico/diagnóstico , Humanos , Reprodutibilidade dos Testes
2.
Front Pharmacol ; 10: 360, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31073287

RESUMO

Objectives: Raynaud's phenomenon (RP) is characterized by intense vasospasm of the digital arteries that causes characteristic color changes in fingers. There are two main types of RP: Primary RP (PRP) and Secondary RP (SRP). PRP is a benign condition. Whilst SRP is associated with several connective tissue diseases (CTD), in particular systemic sclerosis (SSc). The objectives of this report were: to present a short review on morphological (nailfold videocapillaroscopy, NVC) and functional techniques (laser tools and thermography) that allow for a correct diagnosis and treatment of RP and to investigate blood perfusion (BP) by laser speckle contrast analysis (LASCA) in different skin areas of hands and face in PRP, SRP to SSc, and healthy subjects (CNT). Methods: 31 PRP patients (LeRoy criteria), 70 SRP to SSc (ACR/EULAR criteria) and 68 CNT were enrolled. BP was assessed by LASCA at the level different areas of hands and face. NVC was performed to distinguish between PRP and SRP, and to detect the proper pattern of nailfold microangiopathy in SSc patients. Results: Both PRP and SRP showed a statistically significant lower BP than CNT at the level of fingertips (p < 0.0001), periungual (p < 0.0001), palmar aspect of 3rd finger (p < 0.0001), and palm areas (p < 0.0001). Moreover, BP was significantly lower in PRP than in SRP to SSc with the "Early" pattern of microangiopathy in the same areas as above (p < 0.04). Conclusion: By considering a small cohort of patients, BP of hands was found lower in PRP than in SSc patients with the "Early" NVC pattern of microangiopathy.

3.
Microcirculation ; 25(4): e12447, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29527781

RESUMO

BACKGROUND: Absolute nailfold capillary number should be a putative biomarker in selected rheumatic diseases but could be time-consuming and not highly repeatable. OBJECTIVE: To validate an automated software for absolute nailfold capillary number and density evaluation, on NVC images in SSc. METHODS: An automated software to count nailfold capillary number (AUTOCAPI) had been constructed, through an exploratory image set. Subsequently, application rules have been created to define the ROI in NVC images, through a training images set. The software reliability was assessed through calculation of the ICC between automatic and manual counting, by four independent observers, on the same NVC images. RESULTS: The following ICC's were obtained per observer, for the patients with SSc (40 images), the healthy (20 images), and the PRP subgroups (20 images), respectively: 0.94, 0.81, and 0.62 (observer 1); 0.94, 0.91, and 0.67 (observer 2); 0.88, 0.56, and 0.64 (observer 3); and 0.88, 0.85, and 0.85 (observer 4). CONCLUSIONS: The validation of an automated software for measuring absolute nailfold capillary number and density in SSc was achieved. The integration into the pre-existing imaging software should make the assessment of the capillary number in NVC easier, quicker, and standardized.


Assuntos
Capilares/diagnóstico por imagem , Angioscopia Microscópica/métodos , Escleroderma Sistêmico/fisiopatologia , Automação , Humanos , Angioscopia Microscópica/normas , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA