Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Med Phys ; 50(11): 7203-7213, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37517077

RESUMO

BACKGROUND: Many studies have utilized optical camera systems with volumetric scintillators for quality assurances (QA) to estimate the proton beam range. However, previous analytically driven range estimation methods have the difficulty to derive the dose distributions from the scintillation images with quenching and optical effects. PURPOSE: In this study, a deep learning method utilized to QA was used to predict the beam range and spread-out Bragg peak (SOBP) for two-dimensional (2D) map conversion from the scintillation light distribution (LD) into the dose distribution in a water phantom. METHODS: The 2D residual U-net modeling for deep learning was used to predict the 2D water dose map from a 2D scintillation LD map. Monte Carlo simulations for dataset preparation were performed with varying monoenergetic proton beam energies, field sizes, and beam axis shifts. The LD was reconstructed using photons backpropagated from the aperture as a virtual lens. The SOBP samples were constructed based on monoenergetic dose distributions. The training set, including the validation set, consisted of 8659 image pairs of LD and water dose maps. After training, dose map prediction was performed using a 300 image pair test set generated under random conditions. The pairs of simulated and predicted dose maps were analyzed by Bragg peak fitting and gamma index maps to evaluate the model prediction. RESULT: The estimated beam range and SOBP width resolutions were 0.02 and 0.19 mm respectively for varying beam conditions, and the beam range and SOBP width deviations from the reference simulation result were less than 0.1 and 0.8 mm respectively. The simulated and predicted distributions showed good agreement in the gamma analysis, except for rare cases with failed gamma indices in the proximal and field-marginal regions. CONCLUSION: The deep learning conversion method using scintillation LDs in an optical camera system with a scintillator is feasible for estimating proton beam range and SOBP width with high accuracy.


Assuntos
Aprendizado Profundo , Terapia com Prótons , Prótons , Terapia com Prótons/métodos , Simulação por Computador , Método de Monte Carlo , Água , Dosagem Radioterapêutica
2.
Sensors (Basel) ; 22(7)2022 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-35408376

RESUMO

The development of unmanned aerial vehicles (UAVs) is expected to become one of the most commercialized research areas in the world over the next decade. Globally, unmanned aircraft have been increasingly used for safety surveillance in the construction industry and civil engineering fields. This paper presents an aerial image-based approach using UAVs to inspect cracks and deformations in buildings. A state-of-the-art safety evaluation method termed SMART SKY EYE (Smart building safety assessment system using UAV) is introduced; this system utilizes an unmanned airplane equipped with a thermal camera and programmed with various surveying efficiency improvement methods, such as thermography, machine-learning algorithms, and 3D point cloud modeling. Using this method, crack maps, crack depths, and the deformations of structures can be obtained. Error rates are compared between the proposed and conventional methods.


Assuntos
Indústria da Construção , Dispositivos Aéreos não Tripulados , Aeronaves , Algoritmos , Aprendizado de Máquina
3.
Artigo em Inglês | MEDLINE | ID: mdl-32604983

RESUMO

The healthcare and welfare policies of nations, as well as the amount of investments put into these areas, vary across countries. Investments in healthcare and welfare have been increasing worldwide which brings the question of assessing the efficiency of these investments. There are, however, difficulties in evaluating the effectiveness of such investments due to differences in countries' economic development levels and due to the differences in data definition issues. There are only a limited number of studies in the literature that employ consistent and comparable indicators across countries. This study evaluates the healthcare investment efficiency and health competitiveness efficiency of 34 developing countries in Asia using a two-stage dynamic data envelopment analysis approach. Furthermore, we employ a broader measure of indicators on national healthcare and welfare policies and outcomes, in addition to the investment data on healthcare and welfare expenditures. Our findings indicate that the establishment of an investment environment with a consolidated approach and management is an important factor that increases the efficiency of investments in healthcare and welfare sectors. A consistent delivery of the national policy strategy is also crucial for reaching the medium-and long-term targets for each country. For example, if a country establishes healthcare and welfare policies that focus on improving its indicators with low efficiencies, the output will be improved and a better return on investment will be ensured in a long-term perspective.


Assuntos
Atenção à Saúde , Países em Desenvolvimento , Política de Saúde , Ásia , Economia , Eficiência , Feminino , Humanos , Investimentos em Saúde , Dinâmica Populacional , Gravidez
4.
Molecules ; 25(9)2020 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-32397307

RESUMO

5-Amino-7-(2-phenylethyl)-2-(2-furyl)-pyrazolo(4,3-e)-1,2,4-triazolo(1,5-c) pyrimidine (SCH 58261) is one of the new chemical entities that has been developed as an adenosine A2A receptor antagonist. Although SCH 58261 has been reported to be beneficial, there is little information about SCH 58261 from a drug metabolism or pharmacokinetics perspective. This study describes the metabolism and pharmacokinetic properties of SCH 58261 in order to understand its behaviors in vivo. Rats were used as the in vivo model species. First, an LC-MS/MS method was developed for the determination of SCH 58261 in rat plasma. A GastroPlus™ simulation, in vitro microsomal metabolic stability, and bile duct-cannulated studies were also performed to understand its pharmacokinetic profile. The parameter sensitivity analysis of GastroPlus™ was used to examine the factors that influence exposure when the drug is orally administered. The factors are as follows: permeability, systemic clearance, renal clearance, and liver first-pass effect. In vitro microsomal metabolic stability indicates how much the drug is metabolized. The extrapolated hepatic clearance value of SCH 58261 was 39.97 mL/min/kg, indicating that the drug is greatly affected by hepatic metabolism. In vitro microsomal metabolite identification studies revealed that metabolites produce oxidized and ketone-formed metabolites via metabolic enzymes in the liver. The bile duct-cannulated rat study, after oral administration of SCH 58261, showed that a significant amount of the drug was excreted in feces. These results imply that the drug is not absorbed well in the body after oral administration. Taken together, SCH 58261 showed quite a low bioavailability when administered orally and this was likely due to significantly limited absorption, as well as high metabolism in vivo.


Assuntos
Antagonistas de Receptores Purinérgicos P1 , Pirimidinas , Espectrometria de Massas em Tandem , Triazóis , Animais , Disponibilidade Biológica , Cromatografia Líquida , Fígado/metabolismo , Masculino , Microssomos Hepáticos/metabolismo , Antagonistas de Receptores Purinérgicos P1/química , Antagonistas de Receptores Purinérgicos P1/farmacocinética , Antagonistas de Receptores Purinérgicos P1/farmacologia , Pirimidinas/química , Pirimidinas/farmacocinética , Pirimidinas/farmacologia , Ratos , Ratos Sprague-Dawley , Triazóis/química , Triazóis/farmacocinética , Triazóis/farmacologia
5.
Eval Program Plann ; 79: 101775, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31865011

RESUMO

This research aims to contribute to efficiency improvement by providing the implications for decision-making on continuous defense R&D investment strategies and acquisition methods via analyzing the current position and measuring the efficiency of overall weapon systems on technological competence and operations. This research is distinctive in comparison to previous studies because it is structured in a two-stage DEA analysis for efficiency by distinguishing between the technology and operations of the current eight fields of weapon systems and by adding the external index for government competence and market competence. In 2016, in comparison to the year 2013, the eight major weapon systems' efficiency fields of the overall system of Korea, efficiency of technological competence, and efficiency of operations all increased. This research introduced the input and output variable that fits in with the defense industry by connecting the weapon systems efficiency with the national innovation system and the sectoral innovation system that are both projected in this industry. It also formed the concepts of technological competence efficiency and operations efficiency using the two-stage Network DEA method.


Assuntos
Eficiência Organizacional , Órgãos Governamentais/organização & administração , Pesquisa/organização & administração , Planejamento Estratégico , Tecnologia/organização & administração , Tomada de Decisões , Humanos , Competência Profissional , Avaliação de Programas e Projetos de Saúde , República da Coreia , Pesquisa/economia , Pesquisa/normas , Tecnologia/normas
6.
Eval Program Plann ; 72: 205-218, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30415092

RESUMO

Although public-private partnerships (PPP) and electronic government (e-government) have proven to be fruitful mechanisms for economic development and emerging economies seem to recognize their importance, consistent methods for analyzing the early planning stages of e-government portfolios are lacking. The present work utilized a comprehensive literature review to understand the evaluation criteria for PPP projects throughout the early-stage planning process. A qualitative meta-synthesis was employed to identify critical factors for PPP and e-government, with a particular focus on developing countries, PPP, and e-government criteria. Our research presents a framework named "PPP4e-Gov" (public-private partnerships for e-government). The framework compares risk and value factors of e-government PPP projects and adopts a weighted scoring model that estimates the risks that should be considered in a project and how much value a given e-government initiative may generate if the PPP option is chosen. As an illustration of how the framework may be used, the paper interviewed ten practitioners in Costa Rica who tried out PPP4e-Gov and showcased how to plan their e-government initiatives.


Assuntos
Países em Desenvolvimento , Governo , Tecnologia da Informação , Internet , Parcerias Público-Privadas/organização & administração , Desenvolvimento Econômico , Humanos , Inovação Organizacional , Avaliação de Programas e Projetos de Saúde , Parcerias Público-Privadas/economia , Pesquisa Qualitativa
7.
Phys Med ; 42: 127-134, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29173905

RESUMO

The new PET tracer, 18F-flurpiridaz, with high myocardial extraction allows quantitative myocardial blood flow (MBF) estimation from dynamic PET data and tracer kinetic modeling. The goal of this study is to determine the optimal imaging protocols and parameters using a realistic simulation study. The time activity curves (TACs) of different tissue organs from a 30-s infusion time (IT) of 18F-flurpiridaz in a dynamic PET study were extracted from a previous study. The TACs at different time points were incorporated in a series of realistic 3D XCAT phantoms from which the parameters of a 2-compartment model and the 'true' MBF of 18F-flurpiridaz were determined. The compartmental model was used to generate TACs from 7 additional ITs. PET projection data from the XCAT phantoms were generated using Monte Carlo simulation. They were reconstructed using an OS-EM reconstruction algorithm with different update number (N) to obtain dynamic PET images. The blood and myocardial TACs were derived from the dynamic images from which the MBF and %MBF error was estimated. The %MBF error decreases with increasing N of the OS-EM and levels off after ∼42. The 30-s IT gave the smallest %MBF error that decreases from ∼0.57% to ∼19.40%. The MBF for 2-min, 4-min, 8-min and 16-min IT were statistically significant different from the MBF for 30-s IT (P<0.05). Too fast or too slow infusion time gave higher %MBF error. The optimal imaging protocol in dynamic 18F-flurpiridaz PET for accurate quantitative MBF estimation was 30-s IT and N of ∼42 for the OS-EM.


Assuntos
Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons/métodos , Piridazinas , Compostos Radiofarmacêuticos , Algoritmos , Animais , Simulação por Computador , Vasos Coronários/fisiologia , Humanos , Modelos Biológicos , Método de Monte Carlo , Imagem de Perfusão do Miocárdio/instrumentação , Miocárdio/metabolismo , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/instrumentação , Piridazinas/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Fluxo Sanguíneo Regional , Sus scrofa , Fatores de Tempo
8.
Phys Med Biol ; 55(13): 3827-41, 2010 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-20551503

RESUMO

PET detectors with depth-of-interaction (DOI) encoding capability allow high spatial resolution and high sensitivity to be achieved simultaneously. To obtain DOI information from a mono-layer array of scintillation crystals using a single-ended readout, the authors devised a method based on light spreading within a crystal array and performed Monte Carlo simulations with individual scintillation photon tracking to prove the concept. A scintillation crystal array model was constructed using a grid method. Conventional grids are constructed using comb-shaped reflector strips with rectangular teeth to isolate scintillation crystals optically. However, the authors propose the use of triangularly shaped teeth, such that scintillation photons spread only in the x-direction in the upper halves of crystals and in the y-direction in lower halves. DOI positions can be estimated by considering the extent of two-dimensional light dispersion, which can be determined from the multiple anode outputs of a position-sensitive PMT placed under the crystal array. In the main simulation, a crystal block consisting of a 29x29 array of 1.5 mmx1.5 mmx20 mm crystals and a multi-anode PMT with 16x16 pixels were used. The effects of crystal size and non-uniform PMT output gain were also explored by simulation. The DOI resolution estimated for 1.5x1.5x20 mm3 crystals was 2.16 mm on average. Although the flood map was depth dependent, each crystal was well identified at all depths when a corner of the crystal array was irradiated with 511 keV gamma rays (peak-to-valley ratio approximately 9:1). DOI resolution was better than 3 mm up to a crystal length of 28 mm with a 1.5x1.5 mm2 or 2.0x2.0 mm2 crystal surface area. The devised light-sharing method allowed excellent DOI resolutions to be obtained without the use of dual-ended readout or multiple crystal arrays.


Assuntos
Simulação por Computador , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Eletrodos , Desenho de Equipamento , Raios gama , Luz , Método de Monte Carlo , Fótons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA